Loading...
HomeMy WebLinkAbout2025-04-22 - AGENDA REPORTS - 2025 MUNICODE UPDATEO CITY OF SANTA CLARITA AGENDA REPORT PUBLIC HEARINGS Agenda Item: 2 CITY MANAGER APPROVAL: Li ' DATE: April 22, 2025 SUBJECT: 2025 MUNICIPAL CODE UPDATES - FIRST READING DEPARTMENT: Community Development PRESENTER: Andy Olson RECOMMENDED ACTION City Council: 1. Conduct the public hearing. 2. Determine that the project is exempt from environmental review pursuant to California Environmental Quality Act under CEQA Guidelines Section 15061(b)(3), the common-sense exemption. 3. Introduce an ordinance entitled: "AN ORDINANCE OF THE CITY COUNCIL OF THE CITY OF SANTA CLARITA, CALIFORNIA, APPROVING MASTER CASE 24-112, CONSISTING OF UNIFIED DEVELOPMENT CODE AMENDMENT 24-001 (UDC24- 001) AND SPECIFIC PLAN AMENDMENT 24-001 (SP24-001), AMENDING THE SANTA CLARITA MUNICIPAL CODE, OLD TOWN NEWHALL SPECIFIC PLAN, LYONS CORRIDOR PLAN, AND SOLEDAD CORRIDOR PLAN AS SHOWN IN EXHIBITS A-H," waive reading of the text and consent to read by title only, as listed on the agenda, and pass to a second reading. BACKGROUND The City of Santa Clarita (City) periodically updates the Santa Clarita Municipal Code (SCMC) and other planning documents to reflect current legislation and regulations, planning trends, and newly -identified planning issues. This helps to clarify code language in an effort to keep it relevant, fresh, and easy to understand and implement. The last comprehensive planning update of the SCMC was in July 2022. The proposed updates include text amendments to SCMC Chapter 2 (Administration and Personnel), Chapter 17 (Zoning), and Chapter 23 (Neighborhood Preservation); the Old Town Newhall Specific Plan (OTNSP); the Lyons Corridor Plan (LCP); and the Soledad Canyon Road Corridor Plan (SCP). Page 1 Packet Pg. 127 O City staff presented these proposed amendments to the City Council Development Committee on February 18, 2025, and to the Planning Commission on March 18, 2025. The Planning Commission, in a 5-0 vote, adopted a resolution recommending the City Council adopt an ordinance and approve Master Case 24-112, with its associated entitlements. The Planning Commission agenda report is available in the City Clerk's reading file. PROJECT DESCRIPTION The proposed project would update the SCMC, OTNSP, LCP, and SCP. The proposed amendments were prepared by City staff in coordination with the City Attorney's Office. The project consists of text amendments only; no changes to the City's zoning map or development densities are proposed. The proposed amendments would address state and federal legislation and regulatory requirements, streamline processes, enhance customer service, and improve consistency and clarity in the SCMC. No construction or development is proposed as part of the proj ect. Amendments to address state and federal legislation and regulation Parking Minimums: Assembly Bill (AB) 2097 limits the City's ability to impose minimum parking requirements within one-half mile of a major transit stop. Generally, parking requirements may not be enforced on a project unless the City can identify substantially negative impacts on existing residential or commercial parking within one-half mile of the project. The proposed amendments would require those applicants invoking AB 2097 to prepare a parking demand study. Wireless Communications Facilities (WCF): The Federal Communications Commission expanded the area where ground -mounted equipment is required to be permitted when a new WCF co -locates with an existing facility. The amendments would allow ground -mounted equipment within 30 feet of existing ground -mounted equipment. Accessory Dwelling Units (ADU): Senate Bill (SB) 897 and AB 2221 increased the allowable heights for ADUs from 16 feet to up to 18 to 25 feet. In addition, AB 1211 increased the number of detached ADUs permitted on multifamily properties from two ADUs to eight, and also prohibited the City from requiring the replacement of any parking that is demolished to construct an ADU. The proposed amendments reflect these changes. Thrift Stores: The City's current zoning regulations require a Minor Use Permit (MUP) for secondhand stores and a Conditional Use Permit for thrift stores; AB 2632 requires that thrift stores now be permitted in the same manner as non -thrift retail stores. The proposed amendments would update use charts to treat secondhand and thrift stores similarly to non -thrift stores and also create standards for any proposed donation collections at thrift stores. SB 35 Projects: Proposed language addresses AB 2668, which requires that projects meeting the provisions of SB 35 cannot be subjected to conditional use permits and other non -legislative discretionary permits. Page 2 Packet Pg. 128 O Amendments to streamline processes and enhance customer service Jobs Creation Overlay Zone (JCOZ): The 21-day JCOZ appeal period conflicts with the standard 15-day appeal period for public hearings. For JCOZ projects that are approved or denied at a public hearing, the proposed language would make the appeal period consistent with the standard 15-day appeal period. Architectural Enhancement: Commercial, industrial, and higher density residential zones allow for additional height beyond the building height for architectural screening and enhancements. Proposed language would make the Mixed -Use Corridor zone, LCP, and SCP consistent with these zones. Mobile Pickup for Retail Businesses: Proposed language would establish clear development standards, including lighting and parking stall size, and allow for streamlined review for mobile pickup improvements for retail businesses. Golf Cart and Low -Speed Vehicle Sales and Services: Proposed language would expand and rename the Motorcycle Sales and Services land use category to incorporate sales and services of golf carts and other low -speed vehicles. Drive -Through Queuing: Proposed language would update the queuing analysis requirements for new drive -through uses to require local examples, when available. Residential Energy Storage: Proposed language would establish the setbacks and planning requirements for residential energy storage (e.g., backup battery systems), consistent with standards for other wall -mounted or freestanding equipment (e.g., water heaters, air conditioners, heaters). Residential Accessory Structures: Proposed language would revise the number of residential accessory structures (e.g., pool houses, barns, and detached garages) permitted -by -right (without an MUP) to be based on lot size instead of zoning designation. This would not alter the number of ADUs permitted on a property, or unenclosed structures, such as patio covers. Public Nuisance Enforcement: Proposed language would broaden the entities that can be held accountable for public nuisances, such as vacation rental companies. Amendments for consistency and clarity The proposed amendments also include minor updates for consistency and clarity, including: • Reference corrections for ridgeline preservation and commercial gating; • Correction of a footnote for Personal Services in the OTNSP; • Clarification that the City Council will make any necessary determinations that are related to consistency with the General Plan in compliance with Government Code Section 65402; Page 3 Packet Pg. 129 O • Replacing the term "open space" language for multifamily developments to instead reference private outdoor space and shared recreation facilities; • Elimination of affordable housing and density bonus land use charts that are superseded by state legislation; • Clarification that commercial auto storage is usually, but not always, for a fee; and • Clarification of development standards for emergency generators and detached residential patio covers. Entitlement Summary A Zoning Code Amendment (UDC24-001) is required to update the SCMC, LCP, and SCP and a Specific Plan Amendment (SP24-001) is required to update the OTNSP. These entitlements are subject to the zoning code amendment and specific plan amendment processes listed in UDC Section 17.28.110(H) and 17.28.120(I). ENVIRONMENTAL STATUS A Notice of Exemption was prepared for the proposed project. The project is exempt from additional environmental review pursuant to the California Environmental Quality Act Guidelines (14 Cal. Code of Regs. § 15000, et seq.) Section 15061(b)(3), the common-sense exemption. The activity is covered by the general rule that CEQA applies only to projects which have the potential for causing a significant effect on the environment. Where it can be seen with certainty that there is no possibility that the activity in question may have a significant effect on the environment, the activity is not subject to CEQA. PUBLIC NOTICING All notices required by law were completed which consisted of a one -eighth page legal advertisement in The Signal newspaper on April 1, 2025. As of the writing of this staff report, City staff has received no correspondence from the community. CONCLUSION The proposed amendments to the SCMC, OTNSP, LCP, and SCP are consistent with the General Plan and support economic development and the general welfare of the City. Accordingly, City staff has drafted the necessary findings of support so that the Planning Commission can make a recommendation of approval to the City Council. ALTERNATIVE ACTION Other action as determined by the City Council. FISCAL IMPACT Approval of the 2025 Municipal Code amendments would have no fiscal impact. Page 4 Packet Pg. 130 O ATTACHMENTS Public Hearing Notice Notice of Exemption Ordinance Page 5 Packet Pg. 131 2.a CITY OF SANTA CLARITA COMMUNITY DEVELOPMENT DEPARTMENT -�' 23920 Valencia Boulevard, Suite 302 Santa Clarita, CA 91355 NOTICE OF PUBLIC HEARING APPLICATION: Master Case 24-112: Unified Development Code Amendment 24-001 and Specific Plan Amendment 24-001 PROJECT LOCATION PROJECT APPLICANT: Citywide City of Santa Clarita PROJECT DESCRIPTION: The City of Santa Clarita (City) is requesting amendments to the City's Municipal Code, including the zoning code (commonly referred to as the Unified Development Code or UDC), as well as amendments to the Old Town Newhall Specific Plan, Lyons Corridor Plan, and Soledad Canyon Road Corridor Plan. The proposed amendments are generally ministerial in nature, and are a part of the City's ongoing efforts to address current legislation and to review, update, and improve the UDC. PLANNING COMMISSION ACTION: On March 18, 2024, the Planning Commission voted 5-0 to recommend that the City Council approve the proposed amendments. Therefore, the City Council will conduct a public hearing on this matter on the following date: DATE: Tuesday, April 22, 2025 TIME: At or after 6:00 p.m. LOCATION: City Hall, Council Chambers 23920 Valencia Blvd., First Floor Santa Clarita, CA 91355 A NOTICE OF EXEMPTION was prepared for the proposed project. The project is exempt from the California Environmental Quality Act (CEQA) under Article 5 Section 15061(b)(3), the common-sense exemption. The activity is covered by the general rule that CEQA applies only to projects which have the potential for causing a significant effect on the environment. Where it can be seen with certainty that there is no possibility that the activity in question may have a significant effect on the environment, the activity is not subject to CEQA. If you wish to challenge the action taken on this matter in court, you may be limited to raising only those issues you or someone else raised at the public hearing described in this notice, or written correspondence delivered to the City of Santa Clarita at, or prior to, the public hearings. For further information regarding this proposal, you may contact the project planner at the City of Santa Clarita, Permit Center, 23920 Valencia Blvd., Suite 140, Santa Clarita, CA 91355. Telephone: (661) 255- 4330. Website: www.santa-clarita.com/planning. Send written correspondence to: 23920 Valencia Blvd., Suite 302, Santa Clarita, CA 91355. Project Planner: Andy Olson, aolson@santaclarita.gov. Mary Cusick, MMC City Clerk Published: The Signal, April 1, 2025 Packet Pg. 132 NOTICE OF EXEMPTION 2.b TO: FROM: [X] County Clerk City of Santa Clarita County of Los Angeles Community Development 12400 E. Imperial Hwy., Rm. 2001 23920 Valencia Boulevard, Suite #302 Norwalk, CA 90650 Santa Clarita, CA 91355 [ ] Office of Planning and Research 1400 Tenth Street Sacramento, CA 95814 F 5NNTA OJ O �9 � �5 9ECEM8�`P DATE: May 13, 2025 PROJECT NAME: 2025 Santa Clarita Municipal Code Updates PROJECT APPLICANT: City of Santa Clarita, Department of Community Development (Contact: Andy Olson; 661.255.4973) PROJECT LOCATION: Citywide PROJECT DESCRIPTION: The City of Santa Clarita is updating the Santa Clarita Municipal Code (SCMC), including text amendments to Chapter 2 (Administration and Personnel), Chapter 17 (Zoning) and Chapter 23 (Neighborhood Preservation); the Old Town Newhall Specific Plan; the Lyons Corridor Plan; and the Soledad Canyon Road Corridor Plan. This is to advise that the [ ] Director of Community Development [ ] Planning Commission [X] City Council of the City of Santa Clarita has approved the above project on May 13, 2025. Review of the project by the Department of Community Development found that the project is exempt from the provisions of the California Environmental Quality Act. EXEMPT STATUS: A Notice of Exemption was prepared for the proposed project. The project is exempt from additional environmental review pursuant to CEQA Guidelines (14 Cal. Code of Regs. § 15000, et seq.) Section 15061(b)(3), the common sense exemption. The activity is covered by the general rule that CEQA applies only to projects which have the potential for causing a significant effect on the environment. Where it can be seen with certainty that there is no possibility that the activity in question may have a significant effect on the environment, the activity is not subject to CEQA. Person or agency carrying out the project: City of Santa Clarita, Department of Community Development. This is to certify that the Notice of Exemption with comments/responses and record of project approval is available for public review at: City of Santa Clarita Community Development Department 23920 Valencia Boulevard, Suite 302 Santa Clarita, California 91355 (661)255-4330 Contact Person/Title: Andy Olson, Associate Planner Signature: Packet Pg. 133 2.c ORDINANCE NO. 25- AN ORDINANCE OF THE CITY COUNCIL OF THE CITY OF SANTA CLARITA, CALIFORNIA, APPROVING MASTER CASE 24-112, CONSISTING OF UNIFIED DEVELOPMENT CODE 24-001 (UDC24-001) AND SPECIFIC PLAN AMENDMENT 24-001 (SP24-001), AMENDING THE SANTA CLARITA MUNICIPAL CODE, OLD TOWN NEWHALL SPECIFIC PLAN, LYONS CORRIDOR PLAN, AND SOLEDAD CANYON ROAD CORRIDOR PLAN AS SHOWN IN EXHIBITS A-H THE CITY COUNCIL OF THE CITY OF SANTA CLARITA, CALIFORNIA, DOES ORDAIN AS FOLLOWS: SECTION 1. FINDINGS OF FACT FOR MASTER CASE 24-112. The City Council makes the following findings of fact: A. The City of Santa Clarita (City) periodically prepares updates to the Santa Clarita Municipal Code (SCMC), including the zoning regulations (Title 17), and to the City's specific plans and corridor plans; B. Title 17 of the SCMC was last updated in July 2022; the Old Town Newhall Specific Plan (OTNSP) was last updated in May 2022; and the Lyons Corridor Plan (LCP) and Soledad Corridor Plan (SCP) were last updated in December 2020; C. The project was duly noticed in accordance with the public hearing noticing requirements of the SCMC, and a one -eighth page advertisement was placed in The Signal Newspaper on April 1, 2025; D. The City reviewed the project's environmental impacts pursuant to the California Environmental Quality Act (CEQA) (Public Resources Code §§ 21000, et seq.) and the CEQA Guidelines (14 California Code of Regulations §§15000, et seq.; collectively, CEQA); E. City staff presented the project to the City Council Development Committee on February 18, 2025; F. The Planning Commission held a duly noticed public hearing on this issue commencing on March 18, 2025, at 6:00 p.m., or later, at City Hall, 23920 Valencia Boulevard, Santa Clarita, California; G. At the hearing described above, the Planning Commission considered a staff presentation, staff report, and public testimony on the SCMC, OTNSP, LCP, and SCP amendments proposed as part of this project. At the close of the public hearing, the Planning Commission in a 5-0 vote, recommended the City Council approve Master Case 24-112 and its associated entitlements, as shown in Exhibits A-H, which are incorporated by reference; and Page 1 of 6 Packet Pg. 134 2.c H. The City Council held a duly noticed hearing on Master Case 24-112 on April 22, 2025. This Ordinance, and its findings, are made based upon the evidence presented to the City Council at its April 22, 2025, hearing including, without limitation, the staff report submitted by the Community Development Director. SECTION 2. ENVIRONMENTAL ASSESSMENT OF MASTER CASE 24-112. Based upon the foregoing facts and findings, the City Council finds as follows: A. A Notice of Exemption for this project was prepared in compliance with CEQA; B. The project is exempt from CEQA under CEQA Guidelines Section 15061(b)(3), the common sense exemption. The activity is covered by the general rule that CEQA applies only to projects which have the potential for causing a significant effect on the environment. Where it can be seen with certainty that there is no possibility that the activity in question may have a significant effect on the environment, the activity is not subject to CEQA; C. The documents and other materials that constitute the record of proceedings upon which the decision of the City Council is based is the Master Case 24-112 project file and that this project file is located within the Community Development Department and is in the custody of the Director of Community development; and D. Based upon the findings set forth above, the City Council recommends that the City Council find the Notice of Exemption for this project was prepared in compliance with CEQA. SECTION 3. GENERAL FINDINGS FOR MASTER CASE 24-112. Based on the foregoing facts and findings for Master Case 24-112, the City Council determines as follows A. That the proposal is consistent with the General Plan; The project does not include any new development and is consistent with the General Plan's objectives, policies, and procedures. The proposed amendments will assist the City in implementing the General Plan by creating consistent planning documents and updating SCMC sections. Amendments reflect current recent legislation, streamline processes and enhance customer service, and clarify and make consistent code language in an effort to keep the code relevant, useful, and helpful to the residents and businesses of the City. B. The proposal is allowed within the applicable underlying zone and complies with all other applicable provisions of the SCMC and OTNSP; The proposed project would be consistent with the following findings of the OTNSP: OTNSP-1: That the proposed use or project is consistent with the Old Town Newhall Specific Plan. Page 2 of 6 Packet Pg. 135 2.c OTNSP-2: That the proposed use or project meets the development requirements for the Zone within which it is located including parking, architecture, and ground -floor uses. The proposed amendments do not require a consistency finding with the existing code or OTNSP because the project would amend the SCMC, OTNSP, LCP, and SCP in general. While no consistency finding is required, the proposed amendments would not change development densities or the City's zoning map, and the changes are considered to be minor in nature, making the amendments consistent with these aspects of the SCMC. As described above, the project does not include any new development or construction. C. The proposal will not endanger, jeopardize, or otherwise constitute a hazard to the public convenience, health, interest, safety, or general welfare, or be materially detrimental or injurious to the improvements, persons, property, or uses in the vicinity and zone in which the property is located; and Nothing contained in the proposed amendments would endanger, jeopardize, or otherwise constitute a hazard to the public. The proposed amendments consist of minor updates to the SCMC, OTNSP, LCP, and SCP, and are intended to update these planning documents to reflect recent laws, development trends, and to clarify portions of the code where there are inconsistencies or ambiguity. D. The proposal is physically suitable for the site. The factors related to the proposal's physical suitability for the site shall include, but are not limited to, the following: The design, location, shape, size, and operating characteristics are suitable for the proposed use; 2. The highways or streets that provide access to the site are ofsufcient width and are improved as necessary to carry the kind and quantity oftraffic such proposal would generate; 3. Public protection services (e.g., Fire protection, Sheriprotection, etc.) are readily available; and 4. The provision of utilities (e.g., potable water, schools, solid waste collection and disposal, storm drainage, wastewater collection, treatment, and disposal, etc.) is adequate to serve the site. The proposed amendments do not include development of any specific site, and would amend the SCMC in general. The amendments are minor and do not change the scope or goals of the various planning documents or the City's General Plan. No development is proposed or would be approved by the amendments, and any future development that may occur under the revised amendments would require development review and environmental analysis at the time the projects are submitted. The City currently receives adequate service from the Los Angeles County Fire Department and the Los Angeles Page 3 of 6 Packet Pg. 136 2.c County Sheriff's Department. The project area is likewise served by all applicable utilities. Nothing in the proposed amendments would increase the need for fire or police protection services, or increase demand for utilities. SECTION 4. ADDITIONAL FINDINGS FOR UDC24-001. Based upon the foregoing facts and findings for Master Case 24-112 including UDC24-001, the City Council finds as follows: A. The amendments are consistent with the adjacent area, if applicable; The proposed amendments would apply to properties throughout the City and are consistent with the principles of the General Plan. No new development is included with the proposed amendments. B. The amendments are consistent with the principles of the General Plan; The proposed amendments would not alter the General Plan Land Use Map or Zoning Map, nor would the proposed amendments change development densities or population projections for the City. The proposed amendments reflect the requirements of new legislation, revise certain code sections to improve processes and clarify standards, and ensure the code is consistent and easy to interpret. Specifically, the proposed amendments would implement the following objectives and policies of the General Plan: Objective LU 1.2: Maintain the distinctive community character of villages and neighborhoods throughout the planning area by establishing uses, densities, and design guidelines appropriate to the particular needs and goals of each area. Objective LU 4.3: Enhance older commercial and industrial areas. Policy LU 4.1.4: Promote economic opportunity for all segments of the community, including small businesses and new businesses. Policy LU 4.1.5: Provide a clear and consistent planning and permitting process to encourage new development that conforms to the General Plan. Policy LU 4.3.4: Promote business development that upgrades and revitalizes older commercial corridors, including Lyons Avenue, Railroad Avenue/Newhall Avenue, Main Street and Soledad Canyon Road, in a manner that reflects each area's character, architecture, and history. The proposed amendments are consistent with the objectives and policies listed above because they would ensure the City remains compliant with current legislation and provide planning documents that are internally consistent, easier to read, and that provide Page 4 of 6 Packet Pg. 137 2.c clearer direction than the existing code documents provide. The proposed amendments support the character of the City's neighborhoods and promote economic opportunities by providing development standards that are easier to understand and that provide a clear review process. C. Approval ofthe amendments will be in the interest ofpublic health, convenience, safety, and general welfare and in conformity with good zoning practice; The proposed amendments would support the public health, convenience, safety, and general welfare of the community, and are in conformity with good zoning practice because the proposed amendments would standardize planning language and development standards across the planning documents, updating certain sections to reflect new legislation, clarify certain code sections for readability and ease of use, and add new land use categories that support existing and future businesses. D. The amendments are consistent with other applicable provisions of this code; and The proposed text amendments to the SCMC were drafted to be consistent with all other provisions of this code. Further, the proposed text amendments enhance consistency between the SCMC, OTNSP, LCP, and SCP. E. Is necessary to implement the General Plan and/or that the public convenience, the general welfare or good zoning practice justifies such action. The proposed amendments are consistent with the applicable provisions of the SCMC, OTNSP, LCP, and SCP and the proposed revisions would standardize language between the documents and make the documents more consistent with each other. Therefore, the amendments would promote the general welfare and public convenience and would constitute good zoning practice. SECTION 5: DETERMINATION, APPROVALS. The City Council approves Master Case 24-112, consisting of the proposed SCMC, OTNSP, LCP, and SCP amendments as described above and set forth in Exhibits A-H, which are incorporated by reference. SECTION 6: RELIANCE ON RECORD. Each and every one of the findings and determinations in this ordinance are based on the competent and substantial evidence, both oral and written, contained in the entire record relating to the project. The findings and determinations constitute the independent findings and determinations of the Planning Commission in all respects and are fully and completely supported by substantial evidence in the record as a whole. SECTION 7: SUMMARIES OF INFORMATION. All summaries of information in the findings, which precede this section, are based on the substantial evidence in the record. The absence of any particular fact from any such summary is not an indication that a particular finding is not based in part on that fact. SECTION 8. This ordinance becomes effective 30 days after its passage and adoption. Page 5 of 6 Packet Pg. 138 2.c SECTION 9. The City Clerk will certify to the passage of this ordinance and cause it to be published as required by law. PASSED, APPROVED, AND ADOPTED this day of , 2025. MAYOR ATTEST: CITY CLERK DATE: STATE OF CALIFORNIA ) COUNTY OF LOS ANGELES ) ss. CITY OF SANTA CLARITA ) I, Mary Cusick, City Clerk of the City of Santa Clarita, do hereby certify that the foregoing Ordinance No. 25- was regularly introduced and placed upon its first reading at a regular meeting of the City Council on the day of 2025. That thereafter, said ordinance was duly passed and adopted at a regular meeting of the City Council on the day of 2025, by the following vote, to wit: m c AYES: COUNCILMEMBERS: =a L NOES: COUNCILMEMBERS: O r c m ABSENT: COUNCILMEMBERS: E AND I FURTHER CERTIFY that the foregoing is the original of Ordinance No. 25- Q and was published in The Signal newspaper in accordance with State Law (G.C. 40806). CITY CLERK Page 6 of 6 Packet Pg. 139 2.c ENMBIT A: SCMC— REDLINE/STRIKETHROUGH Note that new proposed language is shown in blue underline and current language proposed to be removed is shown in red strikethrough. STATE AND FEDERAL LAW LEGISLATION 17.42.010(4) — Residential Use Types: c. Multifamily —includes a building designed and intended for occupancy by three (3) or (1) Studio-1 enclosed more families living independently of each other, each in a separate dwelling unit, which parking space per unit may be owned individually or by a single landlord. Includes apartments, townhomes, row houses, triplexes, and fourplexes. Accessible parking stalls shall be required in accordance with the Building Code. (2) One bedroom-2 enclosed parking spaces per unit (3) Two bedroom-2 enclosed parking spaces per unit (4) Guest parking-1 parking space per each two units (for complexes with more than 3 units) (5) For senior/age restricted developments, one parking space per each two units, plus required guest parking NU1 NU2 NU3 NU4 NU5 UR1 UR2 UR3 UR4 UR5 CR CC CN BP I X X X X X X X P P P M12 C2 C X X ' Notwithstanding the above, a multifamily project that includes at least twenty percent (20%) of total project units as affordable to lower income households shall be permitted without need for use permit on any of the following parcels: 2861-058-072, 2861-058-073, 2861-058-074, 2861-058-075, 2861-058-076, 2861-058-077, 2861-058-079, 2861-058- 080, 2861-058-081, 2861-058-082, 2861-058-083, 2861-058-084, 2861-058-085, and 2861-058-071. 2Proiects subject to and compliant with all requirements of Government Code Section 65913.4 are permitted without a conditional use permit or any other non -legislative discretionary approval. u_ Packet Pg. 140 2.c 17.35, 17.43 and 17.66 Thrift Stores: 17.43.010(21) Commercial Use Types 21. Retail Sales, Specific Parking o. Second Hand Stores —includes establishments selling pre -owned or used items, including, 1 space per 250 but not limited to, apparel, electronics, furniture and household goods, but does not include square feet antique, coin, vintage clothing, or sporting goods/memorabilia stores. Such establishments must be in accordance with the provisions of Section 17.66.135 (Second Hand and Thrift Stores). NU1 NU2 NU3 NU4 NU5 UR1 UR2 UR3 UR4 UR5 CR CC CN BP I X X X X X X X X X X !4 MP MP MP X p. Swap Meets and Flea Markets —an occasional or periodic market held in an open or As determined by the enclosed structure where groups of individual sellers offer goods for sale to the public. Director NU1 NU2 NU3 NU4 NU5 URI UR2 UR3 UR4 UR5 CR CC CN BP I X X X X X X X X X X C X X X C q. Thrift Stores —includes a shop selling second hand goods, such as clothes, often to benefit 1 space per 250 a charity; also called thrift shop. Thrift stores may, but are not required to have, merchandise square feet, plus donation facilities. Such establishments shall be in accordance with the provisions of parking for Section 17.66.135 (Second Hand and Thrift Stores). merchandise donation facilities NU1 NU2 NU3 NU4 NU5 UR1 UR2 UR3 UR4 UR5 CR CC CN BP I X X X X X X X X X X CP CP CP CP X 17.35.010(B) Mixed Use Corridor (MXC) Zone Permitted Uses Commercial Use Types 12. Retail Sales, General P 13. Retail Sales, Specific a. Department Stores M b. Discount Stores P C. Drugstores P d. Food Stores P e. Liquor Stores C f. Second Hand Stores MP R_ Thrift Stores P gh. Vendors, Long -Term M U_ Packet Pg. 141 2.c 17.35.020(B) Mixed Use Neighborhood (MXN) Zone Permitted Uses Commercial Use Types 12. Retail Sales, General P 13. Retail Sales, Specific a. Department Stores M b. Discount Stores M C. Drugstores P d. Food Stores P e. Liquor Stores C f. Second Hand Stores MP a Thrift Stores P hg. Vendors, Long -Term M 17.35.030(B) Mixed Use Urban Village (MXUV) Zone Permitted Uses Commercial Use Types 12. Retail Sales, General P 13. Retail Sales, Specific a. Department Stores M b. Discount Stores P C. Drugstores P d. Food Stores P e. Liquor Stores C f. Second Hand Stores MI, a- Thrift Stores P gh. Vendors, Long -Term M 17.66.135 Thrift Stores and Second Hand Stores All second hand, thrift, and other retail stores which accept donations are subject to the following, unless otherwise permitted by the Director of Community Development through an Administrative Permit: A. Donations may only be collected within the tenant space. Any outdoor collection areas, if permitted, must be screened from public view. The tenant space and surrounding propeM must be kept free of merchandise, donated items, litter, and refuse. B. Donations may only be collected during the approved hours of operation for the store. Packet Pg. 142 2.c C. The donation process must be operated by store employees and all donations must be collected and received by an employee. D. Donations are an accessory use to the p the square footage of the store. retail use and must be limited to 10 bercent of E. All merchandise. collected donations. and other materials must be stored entirely within the tenant space. No outdoor storage may be permitted. F. Metal storage containers are prohibited. G. Any exterior improvements, such as fagade changes, striping and site design, or accessory structures related to donations and collections are subject to the appropriate review process, including architectural design review and development review. H. Prior to any permit issuance, the store operator must provide a plan describing how donations will be processed, resold, and disposed of, to the Director for review and approval. L Donations must be managed in order to prevent anypublicnuisance. Any dumping at the tenant space is the responsibility of the store and must be removed immediately. J. All signage is subject to separate permit and must be in accordance with Section 17.51.080. The Director may require signage as needed in regards to donations, hours of operation, prohibitions of dumping, and other regulations as needed. 17.51.060(N) — Modification of Off -Street Parking Requirements: 4. Parking Within One -Half Mile of a Major Transit Stop. Except as otherwise provided, parking standards established by this code for developments within one-half mile of a major transit stop may not be imposed. Parking standards within one-half mile of a major transit stop may, however, be imposed when the approving authority finds upon substantial evidence that failing to impose such parking standards would substantially impact (a) the City's ability to meet its share of housing for low and very low income households as established by the Housing Element of the General Plan; (b) the City's ability to meet special housing needs for the elderly or persons with disabilities; or (c) existing residential or commercial parking within one-half mile of the project site. A request for a reduction in the number of parking spaces required by this code and all specific and corridor plans identified in this code is subject to the following requirements: a. Parking Demand Study. To ensure that waiving the minimum parking standards in a development would not substantially negatively impact existing residential or commercial parking within one-half mile of a proiect, any protect seeking to avoid the parking standards of this code in accordance with California law must provide a parking demand study for the proposed proiect, conducted by a licensed traffic engineer or other traffic professional acceptable to the Director. The parking demand study must demonstrate that there is not a negative impact and identify the amount of on -site parking required to prevent a negative impact. The parking demand study is a requirement of the City's entitlement submittal checklists, and a proiect application may not be deemed complete until a satisfactory parking demand study is submitted to and approved by the Director of Community Development. N a� CU a m 0 U CU a .2 _ LO N O N 0 U CU �a 0 _ a) E M U 2 Q Packet Pg. 143 2.c b. Conditions of Approval. The approving authority may impose conditions governing the duration of the permit; operation of the land use; regulation of hours of operation; or such other conditions that the approving authority may deem necessary to ensure the compatibility of the use with surrounding uses, and to preserve the public health, safety, or welfare. c. Permit Does Not Run with the Land. Approval for a reduction of parking within one- half mile of a major transit stop is valid as long as the specific land use(s) remains including, without limitation, tenancy, hours of operation, services or goods offered and a mix activities within the use. The permit does not run with the land. Any change in land use requires a reevaluation of the parking standards. 17.57.040(L) — Accessory Dwelling Units: 17.57.040(L)(2) d. Height. Accessory dwelling units shall must not exceed Meer (164 feet in height unless constructed completely within an existing structure or otherwise permitted below. Neigh . -aAccessory dwelling units may be permitted additional height as described below: i. Where an attached accessory dwelling unit is located on a single-family or multifamily parcel, the accessory dwelling unit must not exceed 25 feet in height or the maximum height permitted for the primary dwelling by the zone, whichever is lower. An accessory dwelling unit is not permitted to exceed two stories in heir ii. Where a detached accessory dwelling unit on a single-family parcel or a multifamily parcel is located within a one-half mile walking distance of public transit, the accessory dwelling unit must not exceed 18 feet in height as measured at the top -plate of the structure. An additional two feet, for a total height of 20 feet, may be permitted only to provide a minimum roof pitch of 2:12. The roof pitch must be consistent with the primary unit to utilize this provision. iii. Where a detached accessory dwelling unit is located on a lot with an existing or proposed multifamily, multistory dwelling unit, the accessory dwelling unit may not exceed 18 feet in heir Accessory dwelling units may not exceed the heights described above, unless an adjustment permit is granted pursuant to Section 17.24.100. f. Parking. One (1) standard parking space (nine (9) feet wide by eighteen (18) feet deep) is required for each new construction accessory dwelling unit. The required parking space shall be m r Q. M m 0 U Q. 2 0 LO N O N m c M c O r c m 0 a Packet Pg. 144 2.c located on the same parcel upon which the primary dwelling unit and the accessory dwelling unit are located. i. Notwithstanding the above, no parking is required for an accessory dwelling unit if: (A) the accessory dwelling unit is within one-half (1/2) mile walking distance of public transit, (B) the accessory dwelling unit is entirely within the proposed or existing primary residence or accessory structure, (C) the accessory dwelling unit has no bedrooms, (D) when on -street parking permits are required but not offered to the accessory dwelling unit, or (E) where there is a car share vehicle located within one (1) block of the accessory dwelling unit. ii. Where a garage, carport, or -covered parking space, or uncovered parking space is demolished or converted in conjunction with the construction of an accessory dwelling unit, replacement parking is not required for the primary unit, except that replacement parking is required for the primary unit where a junior accessory dwelling unit is constructed in an attached garage. 17.57.040(L)(3)(b) ii. Detached Accessory Dwelling Units. Not more than eight (8) detached accessory dwelling units are permitted on a lot with an existing multifamily dwelling, provided that the number of accessory dwelling units does not exceed the number of existing units on the lot. Not more than two (2) detached accessory dwelling units are permitted per lot with a proposed multifamily dwelling. Each accessory dwelling unit shall have at least four (4) foot side and rear yard setbacks and be no more than sixteen (16) feet in height. Required parking, open space, or other amenities or site improvements required by the conditions of approval that are demolished to construct these accessory dwelling units shall be replaced on site prior to occupancy of the first accessory dwelling unit. Detached accessory dwelling units are not permitted on a lot that includes one (1) or more attached accessory dwelling units. 17.69.030(F) - Co -locations and Modifications on All Property Other Than City Right -of - Way. 4. A proposal that includes excavation or deployment of equipment outside the current wireless communications facility site, except that, for towers other than towers in the public right-of-way, it entails any excavation or deployment of transmission equipment outside the current site by more than 30 feet in any direction. The site boundary from which the 30 feet is measured excludes any access or utility easements currently related to the site. For the purposes of this provision, "outside of the current wireless communications facility site" means: a. Outside the boundaries of the controlled, leased or owned property surrounding the wireless tower and base station and any access or utility easements related to the site as shown on the approved plans with respect to a facility outside of a public right-of-way; and C. Packet Pg. 145 2.c b. Outside the proximity of the footprint of the existing ground -mounted transmission equipment with respect to a facility that extends into the public right-of-way. STREAMLINING & CUSTOMER SERVICE 17.38.015 JC — Jobs Creation Overlay Zone: 5. Appeals. If a written request for an appeal to the Planning Commission is received prior to the close of business on the twenty-first day after the notice is dated, a public hearing with the Planning Commission shall be scheduled. Appeals shall be conducted consistent with Section 17.07.040. If the request for a public hearing is rescinded prior to the noticing of the public hearing, no public hearing will be required. Where a project utilizing the provisions of the JC overlay zone is considered in a public hearing, a written request for an appeal must be received before the close of business on the 15`h day after the decision. 17.55.020(A)(1)(b) — Mixed Use Development Standards: b. MXC and MXUV Zones. Buildings and structures in the MXC and MXUV zones may be permitted a height of up to fifty (50) feet. Buildings and structures exceeding fifty (50) feet in height shall require approval of a conditional use permit. i. At the Director's discretion, architectural treatments may exceed 50 feet in height without a conditional use permit, provided, that (1) the addition does not exceed 10 feet in height (for a maximum height of 60 feet); (2) that the allowance would be compatible with the architectural design; and (3) that the allowance would provide additional articulation that could otherwise not be achieved within 50 feet. d U 17.53.020 Commercial and Industrial Development Standards CU =a L W. Mobile Pickup Ar,:as. Parking stalls dedicated to mobile order pickup or other pickup O services for commercial retail businesses must comply with all commercial development standards unless otherwise approved by the Director. The following standards will apply to any E mobile order pickup or similar pickup area located in a commercial parking lot: U Q 1. Anv canobies or other structures must be architecturally consistent with the existing commercial buildings on site, and are subject to an Architectural Design Review. 2. All new lighting must meet the requirements of this code and be shielded and may not spill over to adjacent properties. Packet Pg. 146 2.c 3. A clear and safe path of travel must be provided between the commercial use and mobile pickup area. Walkways must be designed to ensure pedestrian safety and effective traffic flow. 4. Parking stalls and loading zones must comply with all parking dimensions and standards identified in this code. Sufficient loading areas must be provided for all parkin stalls. talls. 5. A permanent pedestrian ramp must be installed, if no existing ramp is provided, to allow carts to access the pickup area from the commercial business. 6. Parking stalls for mobile pickup areas are counted as required parking for a business. 7. Modifications to drive aisles or driveways, or other changes to the configuration of the site are subject to the Development Review process. 8. No signage is permitted except as otherwise allowed by this code as to private property. -WX. Unless otherwise stated in Chapter 17.47 (Temporary Use Types), the occupancy of vehicles, including recreational vehicles, trailers, or vessels, as a residence, temporary or permanent, is prohibited in all zones. (Ord. 13-8 § 4 (Exhs. A, D), 6/11/13; Ord. 20-10 § 6, 12/8/20) 17.43 and 17.38 Golf Cart and Low Speed Vehicle Sales and Services 17.43.010(27)(d) — Vehicle Sales and Services d. Motor-ey-eWPersonal/Other Vehicle Sales and Services —includes establishments primarily 1 space per each engaged in the sale, repair, rental and/or servicing of motorcycles, motorized bikes, all -terrain 400 square feet vehicles, golf carts, low -speed vehicles, -and personal watercraft, and other similar vehicles. NU1 NU2 NU3 NU4 NU5 UR1 UR2 UR3 UR4 UR5 CR CC CN BP I X X X X X X X X X X C C C M M 17.38.100 VS — Vehicle Services Overlay Zone 1. Vehicle Sales and Services a. Automobile and Light Truck Sales and Services i. Body Repair and Painting M ii. Commercial Storage M iii. Gas Sales P iv. Repair and/or Maintenance P Iv- (A) Sales X Packet Pg. 147 2.c (B) Rentals P b. Boat and Camper/R.V. Sales and Services i. Commercial Storage M ii. Repair P iii. Sales and Rental P c. Mete a Personal/Other Vehicle Sales and Services P 17.57 — Solar Batteries and Enemy Storage Devices: 17.57.020 — Residential Development Standards H. Modifications of Garages. Conversions of existing required garages into habitable space are permitted only following the issuance of a certificate of occupancy for a new garage consistent with the residential parking requirements. Modifications shA4- are not permitted which reduce the interior dimensions to less than_ {204 feet by vwewy{204 feet for two ( }car garages, or two (4ten_-(" foot by tweff�y420_)-foot garages in the case of single car garages. Clear entry s must be provided for all garages at a minimum of si*teeff (164 feet for two ( }car garages and eight (4feet for single car garages. Accessory dwelling units located within a garage Beare subject to Section 17.57.040(L). Wall -mounted equipment within the minimum reauired aaraue space identified above must clear a minimum of three and a half feet above the ground and may not impede vehicle parking. 17.57.050 — Distance Between Buildings C. Projections Permitted Between Buildings. The following projections are permitted within the required distance between buildings, provided they are developed subject to the same standards as and not closer to a line midway between such buildings than is permitted in relation to a side lot line within a required interior side yard: 1. Eaves and cantilevered roofs; 2. Fireplace structures, buttresses and wing walls; Rain conductors and spouts, water tables, sills, capitals, cornices and belt courses; 4. Awnings and canopies; 5. Water heaters, water softeners, wall -mounted air conditioning units, electric vehicle chargers, solar batteries and other energy storage equipment, as or electric meters, including service conductors and pipes, or other similar utilities as determined by the Director; Packet Pg. 148 6. Stairways and balconies above the level of the first floor. 17.57.040(K) —Accessory Structure/Outbuilding: a. The parcel shall be zoned any of the following categories: NU1, NU2, NU3, NU4, NU5, UR1, UR2, UR3, UR4, UR5, MXC, MXN, MXUV, PI, OS, OS -A, OS-NF, or OS-BLM. b. The parcel shall contain a legal single-family dwelling as the primary use (primary dwelling unit). am PA ljo Pis, . . . . „ c. The number of accessory structures/outbuildings permitted per parcel is as follows: i. For parcels less than 20,000 square feet in size, a maximum of one accessory structure/outbuilding is permitted. ii. For parcels that are at least 20,000 square feet, but less than one acre in size, a maximum of two accessory structure/outbuildings are permitted. iii. For parcels that are one acre or greater in size, a maximum of three accessory structure/outbuildings are permitted. iv. Additional accessory structures/outbuildings beyond the number described above may be permitted if a minor use permit is obtained. c v. Additional accessory structures/outbuildings which do not require a buildings permit (e.g. p storage sheds,) may be permitted at the discretion of the Director. a� E 17.66.030(D) — Drive -Through Uses: c� r r Q D. All drive -through uses shall have a queuing analysis on file with the Planning Division that details the anticipated operations for the existing or proposed drive -through use. Construction and operation of drive through uses shall comply with the queuing analysis and provide the designated vehicle stacking capacity identified in the analysis. The queuing analysis must include at least one local example of the proposed use or, if none is operational in the City, the analysis must include one comparable local use. However, at no time shall a proposed drive - through use provide vehicle stacking capacity any less than the following minimums: 10 Packet Pg. 149 2.c 23.30 — Public Nuisances: 23.30.020 Definitions "Hosting platform" means a person or entity who collects or receives, a fee, subscription, commission, or other consideration for conducting a booking transaction for home -sharing or vacation rental using any medium of facilitation. "Responsible person" means any person or entity, who is an owner or an agent, occupant, tenant, manager, or representative of an owner, that allows, causes, commits, or maintains any public nuisance violation, as defined by this code, to exist, by any act or the omission of any act or duty. A responsible person is liable for all costs related to a public nuisance violation, regardless of whether the responsible person was present at the real property at the time of the violation. Prior knowledge of Code violations is not required for a finding that an individual is a responsible person. 23.30.040 Nuisances Designated It is unlawful and it is declared to be a public nuisance for any responsible person egg leasing, f havving eharno of possession of or hosting platform to allow, cause, commit, or maintain any property within the City in such a manner that any of the conditions listed below are found to exist. This section is not the exclusive definition or designation of what constitutes a nuisance within this City. It supplements and is in addition to other regulatory codes, statutes, and ordinances enacted by the City, State, or any other legal entity or agency having jurisdiction. Designated public nuisances include the following: CONSISTENCY AND CLEANUP ITEMS 17.26.130 — Ridgeline Alteration Permit: B. Applicability. A ridgeline alteration permit shall be filed as a Class V application, subject to this chapter. The reviewing authority shall review an application for a ridgeline alteration permit for any development, including but not limited to grading permits, building permits and land use entitlements, in the vicinity of a generally designated significant ridgeline designated on the ridgeline preservation overlay zone. Exceptions include minor improvements to existing, developed, single-family homes and property, where the Director may approve projects that require minor grading or are limited in scope such as those regarding yard areas for pool/spa 11 Packet Pg. 150 2.c construction, landscaping, additions to existing structures or construction of accessory structures. A proposed development may also be exempt from the RP overlay zone in accordance with Section 17.38.070(B). When limited in scope and associated with existing single-family residences, the Director may also review projects, or may refer projects to the Planning Commission and/or City Council that require grading of large, flat areas, such as sports courts or riding rings. 17.48.010(27) — Gatin2 of Access and Roadways: d. Commercial property gating in accordance with Section 17.66.050. NUl NU2 NU3 NU4 NU5 URl UR2 UR3 UR4 UR5 CR CC CN BP I X X X X X X X X X X M 11PM _` M M APM 02.26.050 — Duties: G. If requested, Review review proposals for acquisition of property for street, park or other public purposes and report to the appropriate City department as to conformity thereof with the general plan. Notwithstanding any other regulation in this code, the City Council will act as the Planning Auencv for all broiects reauirina findings of General Plan consistencv in accordance with Government Code § 65402 17.49.010 — Development Activities/Miscellaneous Use Types: • \ .. .. 7. Railroad Rights -of -Way Includes the following uses within railroad rights -of -way: a. Operational Activities —includes activities related to the operation of the railroad, including, but not limited to, stations, transit stops, and park and ride facilities. NUl I NU2 I NU3 I NU4 I NU5 I URl I UR2 I UR3 I UR4 I UR5 I CR I CC I CN I BP I I 12 Packet Pg. 151 2.c 7. Railroad Rights -of -Way X I X I X I X X X I X I X I X I X I X I X I X I X I X b. Accessory Activities/Uses—includes trails, bike paths, sidewalks, picnic areas, passive park activities, and landscaping. NU1 NU2 NU3 NU4 NU5 UR1 UR2 UR3 UR4 UR5 CR CC CN BP I X X X X X X X X X X X X X X X c. Storage —includes the storage of any materials, vehicles, goods, and supplies not related to subsection (8)(a) of this section. NUI NU2 NU3 NU4 NU5 URI UR2 UR3 UR4 UR5 CR CC CN BP I X X X X X X X X X X X X X X X 17.43.010(27)(a) — Automobile and Light Truck Sales and Services: (2) Commercial Storage —includes facilities providing overnight and/or long-term storage of As determined automobiles usually, but not always, for a fee, but excludes impound yards. This is an independent by the Director use type and does not include parking that is required for uses pursuant to this code. Typical uses include commercial parking garages. 17.57.060(H) — Setbacks 2. Ground -mounted air conditioners, swimming pool pumps, waterfalls (not exceeding six (6) feet in height), heaters, filters and fans may be located in required rear yards; provided, that they are located not closer than two and one-half (2 1/2) feet to any lot line. These items, as well as other similar appurtenances, are not permitted in the required side yard. Backup generators for incidental. emergencv use and anv associated eauiDment or fuel tanks must be located at least five feet from the side and rear Dronerty lines_ must be screened from view_ and otherwise comply with this code 3. Unenclosed stairways and balconies above the level of the finished elevation of the first floor attached to the primary structure may project a maximum of five (5) feet into a required rear yard; provided, however, that an open work railing not to exceed three and one-half (3 1/2) feet in height may be installed. 4. Swimming pools and spas are permitted in required rear yards; provided, that they are located not closer than five (5) feet from any property line. The setback shall be measured from the water line of a sunken pool or spa or from the structure of an above -ground pool or spa. 5. Structures not exceeding one (1) foot above ground level may be used in any required yard. 13 Packet Pg. 152 2.c 6. Built-in barbecues, fire pits, detached fireplaces and built-in entertainment centers shall be five (5) feet away from property lines and less than ten (10) feet in height, including smoke stacks and chimneys. 7. Except as described elsewhere in this code, accessory buildings and structures, including detached patio covers, may be located within a required rear yard; provided, that they are not closer than five (5) feet to any lot line. 14 Packet Pg. 153 2.c ENMBIT B: SCMC— PROPOSED AMENDMENTS STATE AND FEDERAL LAW LEGISLATION 17.42.010(4) — Residential Use Types: c. Multifamily —includes a building designed and intended for occupancy by three (3) or (1) Studio-1 enclosed more families living independently of each other, each in a separate dwelling unit, which parking space per unit may be owned individually or by a single landlord. Includes apartments, townhomes, row houses, triplexes, and fourplexes. Accessible parking stalls shall be required in accordance (2) One bedroom-2 with the Building Code. enclosed parking spaces per unit (3) Two bedroom-2 enclosed parking spaces per unit (4) Guest parking —I parking space per each two units (for complexes with more than 3 units) (5) For senior/age restricted developments, one parking space per each two units, plus required guest parking NU1 NU2 NU3 NU4 NU5 UR1 UR2 UR3 UR4 UR5 CR CC CN I BP I I X X X X X X X P P P Ml' 2 C2 CZ X X ' Notwithstanding the above, a multifamily project that includes at least twenty percent (20%) of total project units as affordable to lower income households shall be permitted without need for use permit on any of the following parcels: 2861-058-072, 2861-058-073, 2861-058-074, 2861-058-075, 2861-058-076, 2861-058-077, 2861-058-079, 2861-058- 080, 2861-058-081, 2861-058-082, 2861-058-083, 2861-058-084, 2861-058-085, and 2861-058-071. 2 Projects subject to and compliant with all requirements of Government Code Section 65913.4 are permitted without a conditional use permit or any other non -legislative discretionary approval. u_ Packet Pg. 154 2.c 17.35, 17.43 and 17.66 Thrift Stores: 17.43.010(21) Commercial Use Types 21. Retail Sales, Specific Parking o. Second Hand Stores —includes establishments selling pre -owned or used items, including, 1 space per 250 but not limited to, apparel, electronics, furniture and household goods, but does not include square feet antique, coin, vintage clothing, or sporting goods/memorabilia stores. Such establishments must be in accordance with the provisions of Section 17.66.135 (Second Hand and Thrift Stores). NU1 NU2 NU3 NU4 NU5 UR1 UR2 UR3 UR4 UR5 CR CC CN BP I X X X X X X X X X X P P P P X p. Swap Meets and Flea Markets —an occasional or periodic market held in an open or As determined by the enclosed structure where groups of individual sellers offer goods for sale to the public. Director NU1 NU2 NU3 NU4 NU5 URI UR2 UR3 UR4 UR5 CR CC CN BP I X X X X X X X X X X C X X X C q. Thrift Stores —includes a shop selling second hand goods, such as clothes, often to benefit 1 space per 250 a charity; also called thrift shop. Thrift stores may, but are not required to have, merchandise square feet, plus donation facilities. Such establishments shall be in accordance with the provisions of parking for Section 17.66.135 (Second Hand and Thrift Stores). merchandise donation facilities NU1 NU2 NU3 NU4 NU5 UR1 UR2 UR3 UR4 UR5 CR CC CN BP I X X X X X X X X X X P P P P X 17.35.010(B) Mixed Use Corridor (MXC) Zone Permitted Uses Commercial Use Types 12. Retail Sales, General P 13. Retail Sales, Specific a. Department Stores M b. Discount Stores P C. Drugstores P d. Food Stores P e. Liquor Stores C f. Second Hand Stores P g. Thrift Stores P h. Vendors, Long -Term M U_ Packet Pg. 155 2.c 17.35.020(B) Mixed Use Neighborhood (MXN) Zone Permitted Uses Commercial Use Types 12. Retail Sales, General P 13. Retail Sales, Specific a. Department Stores M b. Discount Stores M C. Drugstores P d. Food Stores P e. Liquor Stores C f. Second Hand Stores P a Thrift Stores P h. Vendors, Long -Term M 17.35.030(B) Mixed Use Urban Village (MXUV) Zone Permitted Uses Commercial Use Types 12. Retail Sales, General P 13. Retail Sales, Specific a. Department Stores M b. Discount Stores P C. Drugstores P d. Food Stores P e. Liquor Stores C f. Second Hand Stores P g. Thrift Stores P h. Vendors, Long -Term M 17.66.135 Thrift Stores and Second Hand Stores All second hand, thrift, and other retail stores which accept donations are subject to the following, unless otherwise permitted by the Director of Community Development through an Administrative Permit: A. Donations may only be collected within the tenant space. Any outdoor collection areas, if permitted, must be screened from public view. The tenant space and surrounding property must be kept free of merchandise, donated items, litter, and refuse. B. Donations may only be collected during the approved hours of operation for the store. Packet Pg. 156 2.c C. The donation process must be operated by store employees and all donations must be collected and received by an employee. D. Donations are an accessory use to the primary retail use and must be limited to 10 percent of the square footage of the store. E. All merchandise, collected donations, and other materials must be stored entirely within the tenant space. No outdoor storage may be permitted. F. Metal storage containers are prohibited. G. Any exterior improvements, such as facade changes, striping and site design, or accessory structures related to donations and collections are subject to the appropriate review process, including architectural design review and development review. H. Before the Director issues any permit, the store operator must provide a plan describing how donations will be processed, resold, and disposed of, to the Director for review and approval. I. Donations must be managed in order to prevent any public nuisance. Any dumping at the tenant space is the responsibility of the store and must be removed immediately. All signage is subject to separate permit and must be in accordance with Section 17.51.080. The Director may require signage as needed in regards to donations, hours of operation, prohibitions of dumping, and other regulations as needed. 17.51.060(N) — Modification of Off -Street Parking Requirements: 4. Parking Within One -Half Mile of a Major Transit Stop. Except as otherwise provided, parking •1� standards established by this code for developments within one-half mile of a major transit stop may not be imposed. Parking standards within one-half mile of a major transit stop may, a however, be imposed when the approving authority finds upon substantial evidence that failing c to impose such parking standards would substantially impact (a) the City's ability to meet its share of housing for low and very low income households as established by the Housing Element of the General Plan; (b) the City's ability to meet special housing needs for the elderly or persons with disabilities; or (c) existing residential or commercial parking within one-half mile of the project site. A request for a reduction in the number of parking spaces required by this code and o all specific and corridor plans identified in this code is subject to the following requirements: E a. Parking Demand Study. To ensure that waiving the minimum parking standards in a development would not substantially negatively impact existing residential or a commercial parking within one-half mile of a project, any project seeking to avoid the parking standards of this code in accordance with California law must provide a parking demand study for the proposed project, conducted by a licensed traffic engineer or other traffic professional acceptable to the Director. The parking demand study must demonstrate that there is not a negative impact and identify the amount of on -site parking required to prevent a negative impact. The parking demand study is a requirement of the City's entitlement submittal checklists, and a project application may not be deemed 4 Packet Pg. 157 2.c complete until a satisfactory parking demand study is submitted to and approved by the Director. b. Conditions of Approval. The approving authority may impose conditions governing the duration of the permit; operation of the land use; regulation of hours of operation; or such other conditions that the approving authority may deem necessary to ensure the compatibility of the use with surrounding uses, and to preserve the public health, safety, or welfare. c. Permit Does Not Run with the Land. Approval for a reduction of parking within one- half mile of a major transit stop is valid as long as the specific land use(s) remains including, without limitation, tenancy, hours of operation, services or goods offered and a mix activities within the use. The permit does not run with the land. Any change in land use requires a reevaluation of the parking standards. 17.57.040(L) — Accessory Dwelling Units: 17.57.040(L)(2) d. Height. Accessory dwelling units must not exceed 16 feet in height unless constructed completely within an existing structure or otherwise permitted below. Accessory dwelling units may be permitted additional height as described below: i. Where an attached accessory dwelling unit is located on a single-family or multifamily parcel, the accessory dwelling unit must not exceed 25 feet in height or the maximum height permitted for the primary dwelling by the zone, whichever is lower. An accessory c dwelling unit is not permitted to exceed two stories in height. =' m ii. Where a detached accessory dwelling unit on a single-family parcel or a multifamily parcel is located within a one-half mile walking distance of public transit, the accessory dwelling unit must not exceed 18 feet in height as measured at the top plate of the structure. 0 An additional two feet, for a total height of 20 feet, may be permitted only to provide a minimum roof pitch of 2:12. The roof pitch must be consistent with the primary unit to E utilize this provision. r r a iii. Where a detached accessory dwelling unit is located on a lot with an existing or proposed multifamily, multistory dwelling unit, the accessory dwelling unit may not exceed 18 feet in height. Accessory dwelling units may not exceed the heights described above, unless an adjustment permit is granted pursuant to Section 17.24.100. f. Parking. One (1) standard parking space (nine (9) feet wide by eighteen (18) feet deep) is required for each new construction accessory dwelling unit. The required parking space shall be Packet Pg. 158 2.c located on the same parcel upon which the primary dwelling unit and the accessory dwelling unit are located. i. Notwithstanding the above, no parking is required for an accessory dwelling unit if: (A) the accessory dwelling unit is within one-half (1/2) mile walking distance of public transit, (B) the accessory dwelling unit is entirely within the proposed or existing primary residence or accessory structure, (C) the accessory dwelling unit has no bedrooms, (D) when on -street parking permits are required but not offered to the accessory dwelling unit, or (E) where there is a car share vehicle located within one (1) block of the accessory dwelling unit. ii. Where a garage, carport, covered parking space, or uncovered parking space is demolished or converted in conjunction with the construction of an accessory dwelling unit, replacement parking is not required for the primary unit, except that replacement parking is required for the primary unit where a junior accessory dwelling unit is constructed in an attached garage. 17.57.040(L)(3)(b) ii. Detached Accessory Dwelling Units. Not more than eight detached accessory dwelling units are permitted on a lot with an existing multifamily dwelling, provided that the number of accessory dwelling units does not exceed the number of existing units on the lot. Not more than two detached accessory dwelling units are permitted per lot with a proposed multifamily dwelling. Each accessory dwelling unit shall have at least four foot side and rear yard setbacks and be no more than 16 feet in height. Required parking, open space, or other amenities or site improvements required by the conditions of approval that are demolished to construct these accessory dwelling units shall be replaced on site prior to occupancy of the first accessory dwelling unit. Detached accessory dwelling units are not permitted on a lot that includes one or more attached accessory dwelling units. 17.69.030(F) — Co -locations and Modifications on All Property Other Than City Right -of - Way. 4. A proposal that includes excavation or deployment of equipment outside the current wireless communications facility site, except that, for towers other than towers in the public right-of-way, it entails any excavation or deployment of transmission equipment outside the current site by more than 30 feet in any direction. The site boundary from which the 30 feet is measured excludes any access or utility easements currently related to the site. For the purposes of this provision, "outside of the current wireless communications facility site" means: a. Outside the boundaries of the controlled, leased or owned property surrounding the wireless tower and base station and any access or utility easements related to the site as shown on the approved plans with respect to a facility outside of a public right-of-way; and C. Packet Pg. 159 2.c b. Outside the proximity of the footprint of the existing ground -mounted transmission equipment with respect to a facility that extends into the public right-of-way. STREAMLINING & CUSTOMER SERVICE 17.38.015 JC — Jobs Creation Overlay Zone: 5. Appeals. If a written request for an appeal to the Planning Commission is received prior to the close of business on the twenty-first day after the notice is dated, a public hearing with the Planning Commission shall be scheduled. Appeals shall be conducted consistent with Section 17.07.040. If the request for a public hearing is rescinded prior to the noticing of the public hearing, no public hearing will be required. Where a project utilizing the provisions of the JC overlay zone is considered in a public hearing, a written request for an appeal must be received before the close of business on the 15t' day after the decision. 17.55.020(A)(1)(b) — Mixed Use Development Standards: b. MXC and MXUV Zones. Buildings and structures in the MXC and MXUV zones may be permitted a height of up to fifty (50) feet. Buildings and structures exceeding fifty (50) feet in height shall require approval of a conditional use permit. i. At the Director's discretion, architectural treatments may exceed 50 feet in height without a conditional use permit; provided, that (1) the addition does not exceed 10 feet in height (for a maximum height of 60 feet); (2) that the allowance would be compatible with the architectural design; and (3) that the allowance would provide additional articulation that could otherwise not be achieved within 50 feet. m 17.53.020 Commercial and Industrial Development Standards =a L W. Mobile Pickup Areas. Parking stalls dedicated to mobile order pickup or other pickup O services for commercial retail businesses must comply with all commercial development standards unless otherwise approved by the Director. The following standards will apply to any E mobile order pickup or similar pickup area located in a commercial parking lot: r r a 1. Any canopies or other structures must be architecturally consistent with the existing commercial buildings on site, and are subject to an Architectural Design Review. 2. All new lighting must meet the requirements of this code and be shielded and may not spill over to adjacent properties. Packet Pg. 160 2.c 3. A clear and safe path of travel must be provided between the commercial use and mobile pickup area. Walkways must be designed to ensure pedestrian safety and effective traffic flow. 4. Parking stalls and loading zones must comply with all parking dimensions and standards identified in this code. Sufficient loading areas must be provided for all parking stalls. 5. A permanent pedestrian ramp must be installed, if no existing ramp is provided, to allow carts to access the pickup area from the commercial business. 6. Parking stalls for mobile pickup areas are counted as required parking for a business. 7. Modifications to drive aisles or driveways, or other changes to the configuration of the site are subject to the Development Review process. 8. No signage is permitted except as otherwise allowed by this code as to private property X. Unless otherwise stated in Chapter 17.47 (Temporary Use Types), the occupancy of vehicles, including recreational vehicles, trailers, or vessels, as a residence, temporary or permanent, is prohibited in all zones. 17.43 and 17.38 Golf Cart and Low Speed Vehicle Sales and Services 17.43.010(27)(d) — Vehicle Sales and Services d. Personal/Other Vehicle Sales and Services —includes establishments primarily engaged in 1 space per each the sale, repair, rental and/or servicing of motorcycles, motorized bikes, all -terrain vehicles, golf 400 square feet carts, low -speed vehicles, personal watercraft, and other similar vehicles. NUl NU2 NU3 NU4 NU5 UR1 UR2 UR3 UR4 UR5 CR CC CN BP I X X X X X X X X X X C C C M M 17.38.100 VS —Vehicle Services Overlay Zone 1. Vehicle Sales and Services a. Automobile and Light Truck Sales and Services i. Body Repair and Painting M ii. Commercial Storage M iii. Gas Sales P iv. Repair and/or Maintenance P v. (A) Sales X (B) Rentals P Packet Pg. 161 2.c b. Boat and Camper/R.V. Sales and Services i. Commercial Storage M ii. Repair P iii. Sales and Rental P c. Personal/Other Vehicle Sales and Services P 17.57 — Solar Batteries and Energy Storage Devices: 17.57.020 — Residential Development Standards H. Modifications of Garages. Conversions of existing required garages into habitable space are permitted only following the issuance of a certificate of occupancy for a new garage consistent with the residential parking requirements. Modifications are not permitted which reduce the interior dimensions to less than 20 feet by 20 feet for two car garages, or two ten -foot by 20-foot garages in the case of single car garages. Clear entry must be provided for all garages at a minimum of 16 feet for two car garages and eight feet for single car garages. Accessory dwelling units located within a garage are subject to Section 17.57.040(L). Wall -mounted equipment within the minimum required garage space identified above must clear a minimum of three and a half feet above the ground and may not impede vehicle parking. 17.57.050 — Distance Between Buildings C. Projections Permitted Between Buildings. The following projections are permitted within the required distance between buildings, provided they are developed subject to the same standards as and not closer to a line midway between such buildings than is permitted in relation to a side lot line within a required interior side yard: 1. Eaves and cantilevered roofs; 2. Fireplace structures, buttresses and wing walls; Rain conductors and spouts, water tables, sills, capitals, cornices and belt courses; 4. Awnings and canopies; 5. Water heaters, water softeners, wall -mounted air conditioning units, electric vehicle chargers, solar batteries and other energy storage equipment, gas or electric meters, including service conductors and pipes, or other similar utilities as determined by the Director; 6. Stairways and balconies above the level of the first floor. Packet Pg. 162 2.c 17.57.040(1) —Accessory Structure/Outbuilding: a. The parcel must be zoned any of the following categories: NU I, NU2, NU3, NU4, NU5, UR1, UR2, UR3, UR4, UR5, MXC, MXN, MXUV, PI, OS, OS -A, OS-NF, or OS-BLM. b. The parcel must contain a legal single-family dwelling as the primary use (primary dwelling unit). c. The number of accessory structures/outbuildings permitted per parcel is as follows: i. For parcels less than 20,000 square feet in size, a maximum of one accessory structure/outbuilding is permitted. ii. For parcels that are at least 20,000 square feet, but less than one acre in size, a maximum of two accessory structure/outbuildings are permitted. iii. For parcels that are one acre or greater in size, a maximum of three accessory structure/outbuildings are permitted. iv. Additional accessory structures/outbuildings beyond the number described above may be permitted if a minor use permit is obtained. v. Additional accessory structures/outbuildings which do not require a building permit (e.g storage sheds) may be permitted at the discretion of the Director. 17.66.030(D) — Drive -Through Uses: D. All drive -through uses shall have a queuing analysis on file with the Planning Division that details the anticipated operations for the existing or proposed drive -through use. Construction M and operation of drive through uses shall comply with the queuing analysis and provide the designated vehicle stacking capacity identified in the analysis. The queuing analysis must O include at least one local example of the proposed use or, if none is operational in the City, the c analysis must include one comparable local use. However, at no time may a proposed drive- E through use provide vehicle stacking capacity any less than the following minimums: r r a 23.30 — Public Nuisances: 23.30.020 Definitions "Hosting platform" means a person or entity who collects or receives, a fee, subscription, commission, or other consideration for conducting a booking transaction for home -sharing or vacation rental using any medium of facilitation. 10 Packet Pg. 163 2.c "Responsible person" means any person or entity, who is an owner or an agent, occupant, tenant, manager, or representative of an owner, that allows, causes, commits, or maintains any public nuisance violation, as defined by this code, to exist, by any act or the omission of any act or duty. A responsible person is liable for all costs related to a public nuisance violation, regardless of whether the responsible person was present at the real property at the time of the violation. Prior knowledge of Code violations is not required for a finding that an individual is a responsible person. 23.30.040 Nuisances Designated It is unlawful and it is declared to be a public nuisance for any responsible person or hosting platform to allow, cause, commit, or maintain any property within the City in such a manner that any of the conditions listed below are found to exist. This section is not the exclusive definition or designation of what constitutes a nuisance within this City. It supplements and is in addition to other regulatory codes, statutes, and ordinances enacted by the City, State, or any other legal entity or agency having jurisdiction. Designated public nuisances include the following: CONSISTENCYAND CLEANUP ITEMS 17.26.130 — Rid2eline Alteration Permit: B. Applicability. A ridgeline alteration permit shall be filed as a Class V application, subject toto this chapter. The reviewing authority shall review an application for a ridgeline alteration permit •_ for any development, including but not limited to grading permits, building permits and land use entitlements, in the vicinity of a generally designated significant ridgeline designated on the LO ridgeline preservation overlay zone. Exceptions include minor improvements to existing, developed, single-family homes and property, where the Director may approve projects that require minor grading or are limited in scope such as those regarding yard areas for pool/spa construction, landscaping, additions to existing structures or construction of accessory structures. L A proposed development may also be exempt from the RP overlay zone in accordance with 0 Section 17.38.070(B). When limited in scope and associated with existing single-family residences, the Director may also review projects, or may refer projects to the Planning E Commission and/or City Council that require grading of large, flat areas, such as sports courts or riding rings. a 17.48.010(27) — Gating of Access and Roadways: d. Commercial property gating in accordance with Section 17.66.050. NU1 NU2 NU3 NU4 NU5 UR1 UR2 UR3 UR4 UR5 CR CC CN BP I X X X X X X X X X X AP AP AP AP AP 11 Packet Pg. 164 2.c 02.26.050 — Duties: G. If requested, review proposals for acquisition of property for street, park or other public purposes and report to the appropriate City department as to conformity thereof with the general plan. Notwithstanding any other regulation in this code, the City Council will act as the Planning Agency for all projects requiring findings of General Plan consistency in accordance with Government Code § 65402. 17.49.010 — Development Activities/Miscellaneous Use Types: 7. Railroad Rights -of -Way Includes the following uses within railroad rights -of -way: a. Operational Activities —includes activities related to the operation of the railroad, including, but not limited to, stations, transit stops, and park and ride facilities. NU1 NU2 NU3 NU4 NU5 UR1 UR2 UR3 UR4 UR5 CR CC CN BP I X X X X X X X X X X X X X X X b. Accessory Activities/Uses—includes trails, bike paths, sidewalks, picnic areas, passive park activities, and landscaping. NU1 NU2 NU3 NU4 NU5 UR1 UR2 UR3 UR4 UR5 CR CC CN BP I X X X X X X X X X X X X X X X c. Storage —includes the storage of any materials, vehicles, goods, and supplies not related to subsection (8)(a) of this section. NU1 NU2 NU3 NU4 NU5 UR1 UR2 UR3 UR4 UR5 CR CC CN BP I X X X X X X X X X X X X X X X 17.43.010(27)(a) — Automobile and Light Truck Sales and Services: (2) Commercial Storage —includes facilities providing overnight and/or long-term storage of As determined automobiles usually, but not always, for a fee, but excludes impound yards. This is an independent by the Director use type and does not include parking that is required for uses pursuant to this code. Typical uses include commercial parking garages. 17.57.060(H) — Setbacks 2. Ground -mounted air conditioners, swimming pool pumps, waterfalls (not exceeding six (6) feet in height), heaters, filters and fans may be located in required rear yards; provided, that they are located not closer than two and one-half (2 1/2) feet to any lot line. These items, as well as other similar appurtenances, are not permitted in the required side yard. Backup generators for incidental, emergency use and any associated equipment or fuel tanks must be located at least 12 Packet Pg. 165 2.c five feet from the side and rear property lines; must be screened from view; and otherwise comply with this code. 3. Unenclosed stairways and balconies above the level of the finished elevation of the first floor attached to the primary structure may project a maximum of five (5) feet into a required rear yard; provided, however, that an open work railing not to exceed three and one-half (3 1/2) feet in height may be installed. 4. Swimming pools and spas are permitted in required rear yards; provided, that they are located not closer than five (5) feet from any property line. The setback shall be measured from the water line of a sunken pool or spa or from the structure of an above -ground pool or spa. 5. Structures not exceeding one (1) foot above ground level may be used in any required yard. 6. Built-in barbecues, fire pits, detached fireplaces and built-in entertainment centers shall be five (5) feet away from property lines and less than ten (10) feet in height, including smoke stacks and chimneys. 7. Except as described elsewhere in this code, accessory buildings and structures, including detached patio covers, may be located within a required rear yard; provided, that they are not closer than five (5) feet to any lot line. 13 Packet Pg. 166 2.c Ili OLD TOWN NEWHALL SPECIFIC PLAN — REDLINE/STRIKETHROUGH Note that new proposed language is shown in red underline and current language proposed to be removed is shown in red strikethrough. U- Q Packet Pg. 167 2.c 3. RETAIL USES (CONTINUED) 28 Pharmacies/Drugstores X X P P 29 Retail Sales, General X X P P 30 Retail Services X X X P 31 Secondhand Stores X MUP6 {1�16PP6 XP6 32 Specialty Food Stores X P P X 33 Specialty Retail Stores P3 P P X 34 Stationary Stores X P P X 35 Stores with Floor Area up to 6,000 square X P P P feet 36 Stores with Floor Area between 6,000 and X MUP P P 20,000 square feet 37 Stores with Floor Area 20,000 square feet X X MUP MUP or greater 38 Swap Meets/Flea Markets X X X X 39 Thrift Stores X CUP6 G6LPP6 Xp6 40 Tobacco Paraphernalia Stores X CUP CUP CUP UDC 17.11.020 41 Tourist/Visitor-Oriented Retail X P P X 42 Toy Stores X P P X 43 Vendors, Long Term X MUP MUP MUP 4. ENTERTAINMENT USES 1 Adult Business 2 Gambling Uses 3 Hookah Bar/Cigar Club 4 Live Entertainment 5 Live Entertainment, Accessory Background Music 6 Nightclub 7 Theater, Cinema or Performing Arts X X X P X X X X X CUP CUP X CUP3 MUP MUP MUP P3 P P P X CUP CUP CUP CUP3 P P P 5. SERVICES: BUSINESS, FINANCIAL, PROFESSIONAL 1 ATM X P P P 2 Banks/Credit Unions X P P P 74 1 OLD TOWN NEWHALL SPECIFIC PLAN UDC 17.61 Table continued on the following page CHAPTER 4: THE CODE Packet Pg. 168 2.c 5. SERVICES: BUSINESS, FINANCIAL, PROFESSIONAL (CONTINUED) 3 Business Support Services X P1 P P 4 Check Cashing/Currency Transfer Services X X P X 5 Financial Services X P1 P P 6 Professional Offices P3 P' P P 6. SERVICES: GENERAL 1 Call Centers 2 Child Day Care: Large or Small Family Day Care Home 3 Day Care Center: Child or Adult 4 Drive -Through Service 5 Equipment Rental (indoor only) 6 Lodging: Bed & Breakfast Inn (B&B) 7 Lodging: Hotel or Motel 8 Maintenance Service: Client Site Services 9 Mortuary, Funeral Home 10 Personal Services 11 Personal Services, Restricted 12 Tattoo Parlors/Body Piercing Services 7. SERVICES: MEDICAL X X CUP CUP P X X X MUP X MUP MUP X X X X X X P P P X P X X P P CUP X X X P X X P P MUP3 -rll P' P X X X MUP CUP X CUP CUP X 1 Counseling/Lifestyle Management P3 P' P P 2 Hospital Services X X X CUP 3 Medical Marijuana Dispensary X X X X 4 Medical Services: Clinic, Urgent Care X X P P 5 Medical Services: Doctor Office P3 P' P P 6 Medical Services: Extended Care MUP X X CUP 7 Rehabilitation Facility X X X CUP U DC 17.42.010 CHAPTER 4: THE CODE OLD TOWN NEWHALL SPECIFIC PLAN Packet Pg. 169 2.c Wireless Communications Facility, in the public right-of-way, new or modification to 9 existing wireless communications facility AP AP AP AP greater than 250' from any residential use orzone Footnotes: Except where permitted otherwise through the issuance of o Minor Use Permit, this use is allowed only on on upper floor or behind the primary ground floor use. 2Allowed only os port of o vertical mixed -use project, with upper floor residential in o Commercial Building Type 3Use allowed only on streets that hove existing businesses or that ore adjacent to the COP and/orAE Zones. This provision is intended to provide flexibility for parcels adjacent to other commercial uses and is not intended to introduce commercial activities into neighborhoods that ore primarily residential. 4A CUP is not required in certain instances where on entire block is under development. See the descriptions for the COP, AE, and CB zones for more information. SAutomoted Parking located below ground may be permitted by right. Automated Parking located above ground requires the approval of on Architectural Design Review Permit. 6Use subject to the Thrift Stores development standards in Section 17.66.135 of the UDC. 4.2.03. DEVELOPMENT STANDARDS BY ZONE The following development standards apply to the Zones within the OTNSP area. 80 1 OLD TOWN NEWHALL SPECIFIC PLAN CHAPTER 4: THE CODE Packet Pg. 170 2.c A detached structure typically occupie by��one primary residence with private @p@p�cr`�ro gRfg I�FeFor standards related to Accessory Dwelling Units (ADU), refer to UDC 17.57.040. • Lot Width: 50' minimum C1. BUILDING HEIGHT 1- to 2-story volumes per height limits of the applicable Zone per Section 4.2. C2. BUILDING MASSING Attic space may be occupied and not counted as a story when applying the height limits of the applicable Zone. • Main entrance: Accessed directly from and facing the primary street. Access via primary street or alley (if present). When alley is not present, parking and services shall be accessed by a driveway of 10 feet maximum width. For corner lots without access to an alley, vehicular access from side street by a driveway of 16 feet maximum width. • Parking Requirements: • Residential: 2 enclosed spaces per unit (plus /2 space guest parking per unit for multifamily developments). F1. COMMON OPEN SPAff OUTDOORSPACE • Not applicable F2. PRIVATE RESIDENTIAL ^DC"C--P-. OUTDOOR SPACE • Side yard: Not required • Rear yard: 15% of lot area • Front yard: Defined by setback per applicable Zone. F3. SHARED RESIDENTIAL AMENITIES • Not applicable 86 1 OLD TOWN NEWHALL SPECIFIC PLAN CHAPTER 4: THE CODE Packet Pg. 171 2.c Duplexes, triplexes, and quadplexes are multiple -dwelling structures that appear as large houses that are appropriately scaled in relation to adjacent residential buildings. Dwellings can be organized side -by -side or stacked, and accommodate 2, 3, or 4 residential units respectively. For standards related to Accessory Dwelling Units (ADU), refer to UDC 17.57.040. • Lot Width: 50' minimum C1. BUILDING HEIGHT 2-story volumes per height limits of the applicable Zone per Section 4.2. C2. BUILDING MASSING Structures shall be massed as large houses, composed principally of 2-story volumes, each designed to a house - like scale. Structures on corner lots shall have frontages that face and address each street. Attic space may be occupied and not counted as a story when applying the height limits of the applicable Zone. F1. COMMON GPSE OUTDOOR SPACE • Main entrance for all units: Accessed directly from and Not required facing the primary street. For corner lots, entrances from both frontages are encouraged. F2. PRIVATE RESIDENTIALOUTDOOR SPACE • Upper -level units: Accessed by enclosed or open stairs • Ground floor unit: Private yard of at least 150 square accessible from street or shared central space, e.g., feet per unit. courtyard, lobby, etc. • Upper floor units: Balconies subject to approval of Director of Community Development. VEHICULARE. ACCESS AND PARKING • Front yard: Defined by setback per applicable Zone. Access via primary street or alley (if present). F3. SHARED RESIDENTIAL AMENITIES When alley is not present, parking and services shall be accessed by a driveway of 10 feet maximum width. Not required For corner lots without access to an alley, vehicular access from side street by a driveway of 16 feet maximum width. Tandem parking may be permitted subject to the issuance of an MUP. • Parking Requirements: • Residential: 2 covered spaces per unit (plus /2 space guest parking per unit for multifamily developments). CHAPTER 4: THE CODE OLD TOWN NEWHALL SPECIFIC PLAN 1 87 Packet Pg. 172 2.c An attached structure occupied by multiple dwelling units, each occupied by one primary residence, arrayed side - by -side, or a group of detached structures with minimal outdoor sogcigrations between structures. Each unit has private epeR space. Parking may be accommodated at the ground level within each unit/structure (also known as "tuck -under parking") or can be located a separate structure. This type is also synonymous with 'Townhouse." • Lot Width: 25' minimum C1. BUILDING HEIGHT 2- to 3-story volumes per height limits of the applicable Zone per Section 4.2. C2. BUILDING MASSING Structures on corner lots shall have frontages that face and address each street. In a 3-story configuration, a 2-story unit may be stacked over a single -story ground floor unit or 'Tat." The flat shall be accessed by its own front door, and the upper -story unit shall be accessed by a separate front door and stair. • Main entrance for all units: Accessed directly from and facing the primary street. Garages and services shall be accessed from an alley. This Building Type is not allowed on a lot without an alley Tandem parking may be permitted subject to the issuance of an MUP. • Parking Requirements: • Residential: 2 covered spaces per unit (plus /2 space guest parking per unit for multifamily developments). F1. COMMON OPEN -SPAS OUTDOORSPACE • Not required F2. PRIVATE RESIDENTIAL ^nC"VTiT T[C OUTDOOR SPACE • Front yard: Defined by setback per applicable Zone. • Side yard: Not applicable. • Rear yard: 15% of each unit's lot area. • Upper floor units: Balconies subject to approval of Director of Community Development. F3. SHARED RESIDENTIAL AMENITIES • Not required 88 1 OLD TOWN NEWHALL SPECIFIC PLAN CHAPTER 4: THE CODE Packet Pg. 173 2.c Avertically-stacked structure of single -floor dwelling units of similar configuration, typically with one shared public entry, e.g., lobby. Stacked dwellings may contain structured parking, either as a podium or multiple -level subterranean structure, or as an above -grade structure that is screened behind active uses. A stacked dwellings structure may accommodate housing either on the ground and/or on upper floors, depending on the Zone. In the AE Zone, housing should be located above commercial uses. In the N Zone, housing could be located on both the ground and upper floors, subject to the issuance of an MUP. In the N Zone, Live/Work units and limited non-residential uses may also be located on the ground level, subject to the issuance of an MUP. • Lot Width: 125' minimum C1. BUILDING HEIGHT • Per Zone requirements in Section 4.2. C2. BUILDING MASSING • First floor: Footprint per Section 4.2 Second floor: Up to 85% of first -floor footprint; 100% via CUP Third floor: Up to 75% of first -floor footprint; 100% via CUP • Additional floors: Up to 75% of first -floor footprint; 80% via CUP The total square -footage should not exceed 200% of the structure's first -floor footprint, unless allowed via a CUP. • Main entrance: Accessed directly from and facing the primary street. For corner lots, entrances from both frontages are encouraged. • Ground floor units: Accessed directly from and facing a street. • Upper floor units: Accessed via elevator or corridor. Where an alley is present, parking may be accessed through the alley. For corner lots without access to an alley, parking is accessed from the side street through the building. Where an alley is not present, parking is accessed from the street through the building. Required parking can be accommodated in a subterranean structure, above -grade parking structure, covered surface lot, or a combination. Tandem parking may be permitted subject to the issuance of an MUP. Parking Requirements: • Residential: 2 covered spaces per unit (plus /2 space guest parking per unit for multifamily developments). • Non -Residential: 1 space for first 1,500 square feet of new development. See UDC for parking requirements in excess of 1,500 square feet of new development. Parking shall be calculated for the entire property. F1. COMMON ^"DACE OUTDOOR SPACE Each stacked dwelling building shall have at least one common courtyard, forecourt, paseo, patio, roof -top garden, or some other form of epeR spaEeat ground, podium, or upper levels. outdoor space F2. PRIVATE RESIDENTIAL GRENACE OUTDOOR SPACE Each residential unit shall have a private balcony, yard, or other private space, per the following: • Studio:50 squarefeet • One -bedroom: 75 square feet • Two- or more bedrooms: 100 square feet F3. SHARED RESIDENTIALAMENIT] ES Each stacked dwelling building shall have shared recreational facility areas and other shared amenities (e.g., park, children's play area, fitness facility, swimming pool, patio, etc.) per each residential unit per the following: • Studio: 100 square feet • One -bedroom: 150 square feet • Two- or more bedrooms: 200 square feet CHAPTER 4: THE CODE OLD TOWN NEWHALL SPECIFIC PLAN 1 89 Packet Pg. 174 2.c An attached structure consisting of multiple live/work units arrayed side -by -side. One live/work unit consists of one dwelling unit above and/or behind flexible ground floor space that can be used for commercial uses, such as office, retail, or other type of workspace, as allowed by the zone. Each unit has private epeR spaces outdoorspace • Lot Width: 25minimum C1. BUILDING HEIGHT 2- to 3-story volumes per height limits of the applicable Zone per Section 4.2. C2. BUILDING MASSING Structures on corner lots shall have frontages that face and address each street. Refer to UDC 17.66.080 (joint Living and Working Q u a rte rs). • Main entrance for flexible ground -floor space: Accessed directly from and facing the primary street. • Entrance for living space: Accessed through flexible ground -floor space when living space is located behind or above the flexible space. When living space is located above, the upper dwelling unit may be accessed by a separate entrance or stair. Garages and services shall be accessed from an alley. This Building Type is not allowed on a lot without an alley Required parking shall be in a garage, which may be attached to or detached from the dwelling. Tandem parking may be permitted subject to the issuance of an MUP. • Parking Requirements: • Live/Work: 2 spaces (1 of which shall be enclosed) per unit (plus required non-residential parking). • Non -Residential: 1 space for first 1,500 square feet of new development. See UDC for parking requirements in excess of 1,500 square feet of new development. Parking shall be calculated for the entire property. F1. COMMON (II,C SPACE OUTDOOR SPACE Not required N 0 F2. PRIVATE RESIDENTIAL GPEN SPAEE OUTDOOR SPACE N m • Front yard: Def ned by se -,back per app cab e Zone. • Side yard: Not applicable. c • Rear yard: 15% of each unit's lot area. O • Upper floor units: Balconies subject to approval of Director of Community Development. E F3. SHARED RESIDENTIAL AMENITIES Not required Q 90 1 OLD TOWN NEWHALL SPECIFIC PLAN CHAPTER 4: THE CODE Packet Pg. 175 2.c A structure designed for occupancy by commercial uses on either the ground floor or upper floors. Residential uses may also occupy the upper floors. Along Main Street in the AE Zone, only retail, restaurant, entertainment, arts, and/ or similar uses allowed by Section 4.2 are permitted at the ground level fronting the street subject to the Director of Community Development. Office, service, residential, and other similar uses shall be located either on upper floors or at the ground level behind the primary use. Ground level office and service uses are permitted in the COR Zone. • Lot Width: 25' minimum C1. BUILDING HEIGHT 1- to 2-story volumes per height limits of the applicable Zone per Section 4.2. C2. BUILDING MASSING • First floor: Footprint per Section 4.2 • Second floor: Up to 85% of first -floor footprint; 100% via CUP. The total square -footage should not exceed 200% of the structure's first -floor footprint, unless allowed via a CUP. An MUP can allow up to 300% of the first -floor footprint. Modifications in excess of 300% of the first -floor footprint may be allowed subject to the issuance of a CUP. • Main entrance for all commercial units: Accessed directly from and facing the primary street. For corner lots, entrances from both frontages are encouraged. • Main entrance for upper -level residential units: Accessed through lobby directly from and facing a street. Access via primary street or alley (if present). For corner lots without access to an alley, parking is accessed from the side street through the building. Tandem parking may be permitted subject to the issuance of an MUP. Parking Requirements: • Residential: 2 covered spaces per unit (plus /2 space guest parking per unit for multifamily developments). • Non -Residential: 1 space for first 1,500 square feet of new development. See UDC for parking requirements in excess of 1,500 square feet of new development. In the AE zone, non-residential/commercial shall be calculated at 1:350. Parking shall be calculated for the entire property. Each commercial building shall have at least one common courtyard, forecourt, paseo, patio, roof -top garden, or some other form of epeR she at ground, podium, or upper levels. outdoor space F2. PRIVATE RESIDENTIAL ^"Ei OUTDOOR SPACE For commercial buildings with housing, each residential unit shall have a private balcony, yard, or other private space, per the following: • Studio: 50 square feet • One -bedroom: 75 square feet • Two- or more bedrooms: 100 square feet F3. SHARED RESIDENTIAL AMENITIES For commercial buildings with housing, shall have shared recreational facility areas and other shared amenities (e.g., park, children's play area, fitness facility, swimming pool, patio, etc.) per each residential unit per the following: • Studio: 100 square feet • One -bedroom: 150 square feet • Two- or more bedrooms: 200 square feet CHAPTER 4: THE CODE OLD TOWN NEWHALL SPECIFIC PLAN 1 91 Packet Pg. 176 2.c A detached or attached structure (either new or adaptively reused) intended for artisanal industrial activity and sale of products made on -site. Residential use is limited to no more than one dwelling unit for the business owner/operator or an on -site caretaker. The residential unit has private epee -sue This Building Type provides an interior that is open-plan outdoor and supportive of a wide variety of fabrication and assembly activities, and often includes a mezzanine for supporting office area. • Lot Width: 25minimum C1. BUILDING HEIGHT 1-story volume per height limits of the applicable Zone per Section 4.2. C2. BUILDING MASSING Designed as large, single -volume space which may contain a mezzanine space. • Main entrance for flexible ground -floor space: Accessed from any street or yard. • Entrance for living space: Accessed through flexible ground -floor space when living space is located behind or above the flexible space. When living space is located above, the upper dwelling unit may be accessed by a separate entrance or stair. Access via primary street or alley (if present). • Parking Requirements: • Residential: 2 covered spaces per unit (plus /2 space guest parking per unit for multifamily developments).. • Non -Residential: 1 space for first 1,500 square feet of new development. See UDC for parking requirements in excess of 1,500 square feet of new development. In the AE zone, non-residential/commercial shall be calculated at 1:350. Parking shall be calculated for the entire property. OUTDOOR SPACE _ . COMMON L OUTDOORSPACE Not require( F2. PRIVATE RESIDENTIAL ePEN-SPAEE OUTDOOR SPACE • Minimum 50 square feet at ground or upper level. F3. SHARED RESIDENTIAL AMENITIES Not required 92 1 OLD TOWN NEWHALL SPECIFIC PLAN CHAPTER 4: THE CODE Packet Pg. 177 2.c EXHIBIT D: OLD TOWN NEWHALL SPECIFIC PLAN — PROPOSED AMENDMENTS Packet Pg. 178 2.c 3. RETAIL USES (CONTINUED) 28 Pharmacies/Drugstores 29 Retail Sales, General 30 Retail Services 31 Secondhand Stores 32 Specialty Food Stores 33 Specialty Retail Stores 34 Stationary Stores 35 Stores with Floor Area up to 6,000 square feet 36 Stores with Floor Area between 6,000 and 20,000 square feet 37 Stores with Floor Area 20,000 square feet or greater 38 Swap Meets/Flea Markets 39 Thrift Stores 40 Tobacco Paraphernalia Stores 41 Tourist/Visitor-Oriented Retail 42 Toy Stores 43 Vendors, Long Term 4. ENTERTAINMENT USES 1 Adult Business 2 Gambling Uses 3 Hookah Bar/Cigar Club 4 Live Entertainment 5 Live Entertainment, Accessory Background Music 6 Nightclub 7 Theater, Cinema or Performing Arts X X P P X X P P X X X P X MUP6 P6 P6 X P P X P3 P P X X P P X X P P P X MUP P P X X MUP MUP X X X X X CUP6 P6 P6 X CUP CUP CUP UDC 17.11.020 X P P X X P P X X MUP MUP MUP X X X P X X X X X CUP CUP X CUP3 MUP MUP MUP P3 P P P X CUP CUP CUP CUP3 P P P 5. SERVICES: BUSINESS, FINANCIAL, PROFESSIONAL 1 ATM X P P P 2 Banks/Credit Unions X P P P 74 1 OLD TOWN NEWHALL SPECIFIC PLAN UDC 17.61 Table continued on the following page CHAPTER 4: THE CODE Packet Pg. 179 2.c 5. SERVICES: BUSINESS, FINANCIAL, PROFESSIONAL (CONTINUED) 3 Business Support Services X P1 P P 4 Check Cashing/Currency Transfer Services X X P X 5 Financial Services X P1 P P 6 Professional Offices P3 P' P P 6. SERVICES: GENERAL 1 Call Centers X X CUP CUP 2 Child Day Care: Large or Small Family Day P X X X Care Home 3 Day Care Center: Child or Adult MUP X MUP MUP 4 Drive -Through Service X X X X 5 Equipment Rental (indoor only) X X P P 6 Lodging: Bed & Breakfast Inn (B&B) P X P X 7 Lodging: Hotel or Motel X P P CUP 8 Maintenance Service: Client Site Services X X X P 9 Mortuary, Funeral Home X X P P 10 Personal Services MUP3 P1 P X 11 Personal Services, Restricted X X MUP CUP 12 Tattoo Parlors/Body Piercing Services X CUP CUP X 7. SERVICES: MEDICAL 1 Counseling/Lifestyle Management P3 P' P P 2 Hospital Services X X X CUP 3 Medical Marijuana Dispensary X X X X 4 Medical Services: Clinic, Urgent Care X X P P 5 Medical Services: Doctor Office P3 P' P P 6 Medical Services: Extended Care MUP X X CUP 7 Rehabilitation Facility X X X CUP U DC 17.42.010 CHAPTER 4: THE CODE OLD TOWN NEWHALL SPECIFIC PLAN Packet Pg. 180 2.c Wireless Communications Facility, in the public right-of-way, new or modification to 9 existing wireless communications facility AP AP AP AP greater than 250' from any residential use orzone Footnotes: Except where permitted otherwise through the issuance of o Minor Use Permit, this use is allowed only on on upper floor or behind the primary ground floor use. 2Allowed only os port of o vertical mixed -use project, with upper floor residential in o Commercial Building Type. 3Use allowed only on streets that hove existing businesses or that ore adjacent to the COP and/orAE Zones. This provision is intended to provide flexibility for parcels adjacent to other commercial uses and is not intended to introduce commercial activities into neighborhoods that ore primarily residential. 4A CUP is not required in certain instances where on entire block is under development. See the descriptions for the COP, AE, and CB zones for more information. SAutomoted Parking located below ground may be permitted by right. Automated Parking located above ground requires the approval of on Architectural Design Review Permit. 6Use subject to the Thrift Stores development standards in Section 17.66.135 of the UDC. 4.2.03. DEVELOPMENT STANDARDS BY ZONE The following development standards apply to the Zones within the OTNSP area. 80 1 OLD TOWN NEWHALL SPECIFIC PLAN CHAPTER 4: THE CODE Packet Pg. 181 2.c A detached structure typically occupied by one primary residence with private outdoor space on a single lot. For standards related to Accessory Dwelling Units (ADU), refer to UDC 17.57.040. • Lot Width: 50' minimum C1. BUILDING HEIGHT 1- to 2-story volumes per height limits of the applicable Zone per Section 4.2. C2. BUILDING MASSING Attic space may be occupied and not counted as a story when applying the height limits of the applicable Zone. • Main entrance: Accessed directly from and facing the primary street. Access via primary street or alley (if present). When alley is not present, parking and services shall be accessed by a driveway of 10 feet maximum width. For corner lots without access to an alley, vehicular access from side street by a driveway of 16 feet maximum width. • Parking Requirements: • Residential: 2 enclosed spaces per unit (plus /2 space guest parking per unit for multifamily developments). F1. COMMON OUTDOOR SPACE • Not applicable F2. PRIVATE RESIDENTIALOUTDOOR SPACE • Side yard: Not required • Rear yard: 15% of lot area • Front yard: Defined by setback per applicable Zone. F3. SHARED RESIDENTIAL AMENITIES • Not applicable 86 1 OLD TOWN NEWHALL SPECIFIC PLAN CHAPTER 4: THE CODE Packet Pg. 182 2.c Duplexes, triplexes, and quadplexes are multiple -dwelling structures that appear as large houses that are appropriately scaled in relation to adjacent residential buildings. Dwellings can be organized side -by -side or stacked, and accommodate 2, 3, or 4 residential units respectively. For standards related to Accessory Dwelling Units (ADU), refer to UDC 17.57.040. • Lot Width: 50' minimum C1. BUILDING HEIGHT 2-story volumes per height limits of the applicable Zone per Section 4.2. C2. BUILDING MASSING Structures shall be massed as large houses, composed principally of 2-story volumes, each designed to a house - like scale. Structures on corner lots shall have frontages that face and address each street. Attic space may be occupied and not counted as a story when applying the height limits of the applicable Zone. • Main entrance for all units: Accessed directly from and facing the primary street. For corner lots, entrances from both frontages are encouraged. • Upper -level units: Accessed by enclosed or open stairs accessible from street or shared central space, e.g., courtyard, lobby, etc. Access via primary street or alley (if present). When alley is not present, parking and services shall be accessed by a driveway of 10 feet maximum width. For corner lots without access to an alley, vehicular access from side street by a driveway of 16 feet maximum width. Tandem parking may be permitted subject to the issuance of an MUP. • Parking Requirements: • Residential: 2 covered spaces per unit (plus /2 space guest parking per unit for multifamily developments). F1. COMMON OUTDOORSPACE Not required F2. PRIVATE RESIDENTIAL OUTDOORSPACE • Ground floor unit: Private yard of at least 150 square feet per unit. • Upper floor units: Balconies subject to approval of Director of Community Development. • Front yard: Defined by setback per applicable Zone. F3. SHARED RESIDENTIAL AMENITIES • Not required CHAPTER 4: THE CODE OLD TOWN NEWHALL SPECIFIC PLAN 1 87 Packet Pg. 183 2.c An attached structure occupied by multiple dwelling units, each occupied by one primary residence, arrayed side -by - side, or a group of detached structures with minimal separations between structures. Each unit has private outdoor space. Parking may be accommodated at the ground level within each unit/structure (also known as "tuck -under parking") or can be located in a separate structure. This type is also synonymous with "Townhouse." • Lot Width: 25' minimum C1. BUILDING HEIGHT 2- to 3-story volumes per height limits of the applicable Zone per Section 4.2. C2. BUILDING MASSING Structures on corner lots shall have frontages that face and address each street. In a 3-story configuration, a 2-story unit may be stacked over a single -story ground floor unit or 'Tat." The flat shall be accessed by its own front door, and the upper -story unit shall be accessed by a separate front door and stair. F1. COMMON OUTDOOR SPACE • Not required • Main entrance for all units: Accessed directly from and facing the primary street. F2. PRIVATE RESIDENTIAL OUTDOOR SPACE Garages and services shall be accessed from an alley. This Building Type is not allowed on a lot without an alley Tandem parking may be permitted subject to the issuance of an MUP. • Parking Requirements: • Residential: 2 covered spaces per unit (plus /2 space guest parking per unit for multifamily developments). • Front yard: Defined by setback per applicable Zone. • Side yard: Not applicable. • Rear yard: 15% of each unit's lot area. • Upper floor units: Balconies subject to approval of Director of Community Development. F3. SHARED RESIDENTIAL AMENITIES • Not required 88 1 OLD TOWN NEWHALL SPECIFIC PLAN CHAPTER 4: THE CODE Packet Pg. 184 2.c A vertically -stacked structure of single -floor dwelling units of similar configuration, typically with one shared public entry, e.g., lobby. Stacked dwellings may contain structured parking, either as a podium or multiple -level subterranean structure, or as an above -grade structure that is screened behind active uses. A stacked dwellings structure may accommodate housing either on the ground and/or on upper floors, depending on the Zone. In the AE Zone, housing should be located above commercial uses. In the N Zone, housing could be located on both the ground and upper floors, subject to the issuance of an MUP. In the N Zone, Live/Work units and limited non-residential uses may also be located on the ground level, subject to the issuance of an MUP. • Lot Width: 125' minimum C1. BUILDING HEIGHT Per Zone requirements in Section 4.2. C2. BUILDING MASSING • First floor: Footprint per Section 4.2 Second floor: Up to 85% of first -floor footprint; 100% via CUP Third floor: Up to 75% of first -floor footprint; 100% via CUP • Additional floors: Up to 75% of first -floor footprint; 80% via CUP The total square -footage should not exceed 200% of the structure's first -floor footprint, unless allowed via a CUP. • Main entrance: Accessed directly from and facing the primary street. For corner lots, entrances from both frontages are encouraged. • Ground floor units: Accessed directly from and facing a street. • Upper floor units: Accessed via elevator or corridor. Where an alley is present, parking may be accessed through the alley. For corner lots without access to an alley, parking is accessed from the side street through the building. Where an alley is not present, parking is accessed from the street through the building. Required parking can be accommodated in a subterranean structure, above -grade parking structure, covered surface lot, or a combination. Tandem parking may be permitted subject to the issuance of an MUP. Parking Requirements: • Residential: 2 covered spaces per unit (plus /2 space guest parking per unit for multifamily developments). • Non -Residential: 1 space for first 1,500 square feet of new development. See UDC for parking requirements in excess of 1,500 square feet of new development. Parking shall be calculated for the entire property. F1. COMMON OUTDOOR SPACE Each stacked dwelling building shall have at least one common courtyard, forecourt, paseo, patio, roof -top garden, or some other form of outdoor space at ground, podium, or upper levels. F2. PRIVATE RESIDENTIAL OUTDOOR SPACE Each residential unit shall have a private balcony, yard, or other private space, per the following: • Studio: 50 square feet • One -bedroom: 75 square feet • Two- or more bedrooms: 100 square feet F3. SHARED RESIDENTIAL AMENITIES Each stacked dwelling building shall have shared recreational facility areas and other shared amenities (e.g., park, children's play area, fitness facility, swimming pool, patio, etc.) per each residential unit per the following: • Studio: 100 square feet • One -bedroom: 150 square feet • Two- or more bedrooms: 200 square feet CHAPTER 4: THE CODE OLD TOWN NEWHALL SPECIFIC PLAN 1 89 Packet Pg. 185 2.c An attached structure consisting of multiple live/work units arrayed side -by -side. One live/work unit consists of one dwelling unit above and/or behind flexible ground floor space that can be used for commercial uses, such as office, retail, or other type of workspace, as allowed by the zone. Each unit has private outdoor space. • Lot Width: 25' minimum C1. BUILDING HEIGHT 2- to 3-story volumes per height limits of the applicable Zone per Section 4.2. C2. BUILDING MASSING Structures on corner lots shall have frontages that face and address each street. Refer to UDC 17.66.080 (joint Living and Working Q u a rte rs). • Main entrance for flexible ground -floor space: Accessed directly from and facing the primary street. • Entrance for living space: Accessed through flexible ground -floor space when living space is located behind or above the flexible space. When living space is located above, the upper dwelling unit may be accessed by a separate entrance or stair. Garages and services shall be accessed from an alley. This Building Type is not allowed on a lot without an alley Required parking shall be in a garage, which may be attached to or detached from the dwelling. Tandem parking may be permitted subject to the issuance of an MUP. • Parking Requirements: • Live/Work: 2 spaces (1 of which shall be enclosed) per unit (plus required non-residential parking). • Non -Residential: 1 space for first 1,500 square feet of new development. See UDC for parking requirements in excess of 1,500 square feet of new development. Parking shall be calculated for the entire property. F1. COMMON OUTDOOR SPACE • Not required F2. PRIVATE RESIDENTIAL OUTDOOR SPACE • Front yard: Defined by setback per applicable Zone. • Side yard: Not applicable. • Rear yard: 15% of each unit's lot area. • Upper floor units: Balconies subject to approval of Director of Community Development. F3. SHARED RESIDENTIAL AMENITIES • Not required 90 1 OLD TOWN NEWHALL SPECIFIC PLAN CHAPTER 4: THE CODE Packet Pg. 186 2.c An attached structure consisting of multiple live/work units arrayed side -by -side. One live/work unit consists of one dwelling unit above and/or behind flexible ground floor space that can be used for commercial uses, such as office, retail, or other type of workspace, as allowed by the zone. Each unit has private outdoor space. • Lot Width: 25' minimum C1. BUILDING HEIGHT 2- to 3-story volumes per height limits of the applicable Zone per Section 4.2. C2. BUILDING MASSING Structures on corner lots shall have frontages that face and address each street. Refer to UDC 17.66.080 (joint Living and Working Q u a rte rs). • Main entrance for flexible ground -floor space: Accessed directly from and facing the primary street. • Entrance for living space: Accessed through flexible ground -floor space when living space is located behind or above the flexible space. When living space is located above, the upper dwelling unit may be accessed by a separate entrance or stair. Garages and services shall be accessed from an alley. This Building Type is not allowed on a lot without an alley Required parking shall be in a garage, which may be attached to or detached from the dwelling. Tandem parking may be permitted subject to the issuance of an MUP. • Parking Requirements: • Live/Work: 2 spaces (1 of which shall be enclosed) per unit (plus required non-residential parking). • Non -Residential: 1 space for first 1,500 square feet of new development. See UDC for parking requirements in excess of 1,500 square feet of new development. Parking shall be calculated for the entire property. F1. COMMON OUTDOOR SPACE • Not required F2. PRIVATE RESIDENTIAL OUTDOOR SPACE • Front yard: Defined by setback per applicable Zone. • Side yard: Not applicable. • Rear yard: 15% of each unit's lot area. • Upper floor units: Balconies subject to approval of Director of Community Development. F3. SHARED RESIDENTIAL AMENITIES • Not required 90 1 OLD TOWN NEWHALL SPECIFIC PLAN CHAPTER 4: THE CODE Packet Pg. 187 2.c A structure designed for occupancy by commercial uses on either the ground floor or upper floors. Residential uses may also occupy the upper floors. Along Main Street in the AE Zone, only retail, restaurant, entertainment, arts, and/ or similar uses allowed by Section 4.2 are permitted at the ground level fronting the street subject to the Director of Community Development. Office, service, residential, and other similar uses shall be located either on upper floors or at the ground level behind the primary use. Ground level office and service uses are permitted in the COR Zone. • Lot Width: 25' minimum C1. BUILDING HEIGHT 1- to 2-story volumes per height limits of the applicable Zone per Section 4.2. C2. BUILDING MASSING • First floor: Footprint per Section 4.2 • Second floor: Up to 85% of first -floor footprint; 100% via CUP. The total square -footage should not exceed 200% of the structure's first -floor footprint, unless allowed via a CUP. An MUP can allow up to 300% of the first -floor footprint. Modifications in excess of 300% of the first -floor footprint may be allowed subject to the issuance of a CUP. • Main entrance for all commercial units: Accessed directly from and facing the primary street. For corner lots, entrances from both frontages are encouraged. • Main entrance for upper -level residential units: Accessed through lobby directly from and facing a street. Access via primary street or alley (if present). For corner lots without access to an alley, parking is accessed from the side street through the building. Tandem parking may be permitted subject to the issuance of an MUP. Parking Requirements: • Residential: 2 covered spaces per unit (plus /2 space guest parking per unit for multifamily developments). • Non -Residential: 1 space for first 1,500 square feet of new development. See UDC for parking requirements in excess of 1,500 square feet of new development. In the AE zone, non-residential/commercial shall be calculated at 1:350. Parking shall be calculated for the entire property. F1. COMMON OUTDOOR SPACE Each commercial building shall have at least one common courtyard, forecourt, paseo, patio, roof -top garden, or some other form of outdoor space at ground, podium, or upper levels. F2. PRIVATE RESIDENTIAL OUTDOOR SPACE For commercial buildings with housing, each residential unit shall have a private balcony, yard, or other private space, per the following: • Studio: 50 square feet • One -bedroom: 75 square feet • Two- or more bedrooms: 100 square feet F3. SHARED RESIDENTIAL AMENITIES For commercial buildings with housing, shall have shared recreational facility areas and other shared amenities (e.g., park, children's play area, fitness facility, swimming pool, patio, etc.) per each residential unit per the following: • Studio: 100 square feet • One -bedroom: 150 square feet • Two- or more bedrooms: 200 square feet CHAPTER 4: THE CODE OLD TOWN NEWHALL SPECIFIC PLAN 1 91 Packet Pg. 188 2.c A detached or attached structure (either new or adaptively reused) intended for artisanal industrial activity and sale of products made on -site. Residential use is limited to no more than one dwelling unit for the business owner/operator or an on -site caretaker. The residential unit has private outdoor space. This Building Type provides an interior that is open- plan and supportive of a wide variety of fabrication and assembly activities, and often includes a mezzanine for supporting office area. • Lot Width: 25' minimum C1. BUILDING HEIGHT 1-story volume per height limits of the applicable Zone per Section 4.2. C2. BUILDING MASSING Designed as large, single -volume space which may contain a mezzanine space. • Main entrance for flexible ground -floor space: Accessed from any street or yard. • Entrance for living space: Accessed through flexible ground -floor space when living space is located behind or above the flexible space. When living space is located above, the upper dwelling unit may be accessed by a separate entrance or stair. Access via primary street or alley (if present). Parking Requirements: • Residential: 2 covered spaces per unit (plus /2 space guest parking per unit for multifamily developments).. • Non -Residential: 1 space for first 1,500 square feet of new development. See UDC for parking requirements in excess of 1,500 square feet of new development. In the AE zone, non-residential/commercial shall be calculated at 1:350. Parking shall be calculated for the entire property. F1. COMMON OUTDOOR SPACE Not required LO N F2. PRIVATE RESIDENTIAL OUTDOOR SPACE N Minimum 50 square feet at ground or upper level. c c� F3. SHARED RESIDENTIAL AMENITIES L Not required O c m E t r Q 92 1 OLD TOWN NEWHALL SPECIFIC PLAN CHAPTER 4: THE CODE Packet Pg. 189 2.c EXHIBIT E : LYONS CORRIDOR PLAN — REDLINE/STRIKETHROUGH Note that new proposed language is shown in red underline and current language proposed to be removed is shown in red strikethrough. U- Q Packet Pg. 190 2.c 4.1.010 The Lyons Urban 1 Zone (L--U1) 11 sde Diagram A: Building Placement A. Buimus PUKMExr. 1. PRIMARY BUILDINGS Apnmuy buildingelmll. be placed on slot in oompRancewlth the following requirements, within the hatched area as shown in the diagram above, unless spec f otherwise bytbe standards for an allowed building type in. Chapter 7 (Frontage Type Standards) or Chapter 8 (Building Type Standards). Mamma- MCL a. Front Setback 1' S' With outdoor Ddmr'vng 10. b. Setback 6mm Reddendal7.oneiV 1st story (Bear and Side) 15' 2nd story c. Side Setback 0' d. Side Street Setback 5' e. Pear Alley Setback O'lststory 5'2nd story 3. ARCHITECTURAL ENCROACHMENTS Patios, unouvuxd stoops, roof overhangs, and awnings may encroach 5' ma3dmum into the required front setback (Diagam B). Outdoor dining may encroach into the front setback mLyons Corridor Development Code �i �k 9�. yIlrtl�iosrtY 1I I 3 i g Diagram B: Building Profile B. BuIL01116 PROFILE Axo FA011ME. 1, HEIGHT Each structure sban comply with the following height limits. a. Maximum height: 2 stories shall be permitted. For Bat roof development, the maxmum height to parapet cannot exceed 35 feet from grxlq and for doping roofs, the mwumum height of the roof ridge carmot aeeed 4S feet from grade (Diagram B). b. Accessory structure 15' maximum in peak 2. ALLOWED FRONTAGE TYPES Only the following frontage types era dlmmd wttbin the L-171 zone. 'Ihe streetfidng facade of each primary building shall be designul as one of the fodlw&g frontage types, in compllanee with Chapter? (FrontageType Standards). a. Forecourt (100' minimum lot frontage requited) b. Lightcourt c Shopfront &Awning Should aspects of a certain lot in the L-171 acne preclude development in accordance with the standards listed above, alternative frontage designs may be permitted subject to section 2.1.030.B. At the discretion of the Director, architectural treatments for flat and sloping roofs may exceed 35 feet in height without a conditional use permit; provided, that (1) the addition does not exceed 10 feet in height (for a maximum height of 45 feet); (2) that the allowance would be compatible with the architectural design; and (3) that the allowance would provide additional articulation that could otherwise not be achieved within the heights specified above. as c ca d r L_ IL N d M M Q d O CU S U .E 7 Ley N O N d V C C L 0 r C d E L V M r Q Packet Pg. 191 2.c 4.1.020 The Lyons Urban 2 Ione (L-U2) %c Diagram A: Building Placement A. Buimus PLAiEARENr. 1. PRIMARY BUILDINGS Aprimarybuildnmgsball be placed on slot in oomplisncewdtb the following requirements, within the hatched area as shown in the diagram above, unless spe ified otherwise bytbe standards for an allowed building type in. Chapter 7 (Frontage Type Standards) or Chapter 8 (Building Type Standards). Mimnmm Mu. s. Front Setback 1' S' b. Setback fim Residential 7one10' 1st story (Rear and Side) 15' 2nd story c. Rear and Side Setback 0' d. Side Street Setback 5' e. Rear Alley Setback O'latstory 5'2nd story 3. ARCHITECTURAL ENCROACHMENTS Patios, uncovered stoops, roof overhangs, and awnings may encroach 5' matumum into the required front setback (Diagram B). Outdoor dining may encroach into the front setback ® Lyons Corridor Development Code d I w di Z 'F Diagram B: Building Profile B. BuILOIN6PROFILE ANRFRONME. 1, HEIGHT Each structure shall comply with the following height limits. a. Mmdmum height: 2 stories shall be permitted. For Bat roof development, the maxmum height to parapet cannot exceed 35 feet from grxlq and for doping roofs, the maximum height of the roof ridge cannot areeed 4S feet from grade (Diagram B). b. Accessory structure 15' maximum to peak 2. ALLOWED FRONTAGE TYPES Only the following frontage types era allowed within the L-U2 zone. 'Ihe streetfidng facade of each primary building shall be designed as one of the following frontage types, in compliance with Chapter 7 (FrontageType Standards). a. Forecourt (100' minimum lot frontage required) b. Lightcourt c Shopfront &Awning Should aspects of a certain lot in the L-U2 acne preclude development in accordance with the standards listed above, alternative frontage designs may be permitted subject to section 2.1.030.B. At the discretion of the Director, architectural treatments for flat and sloping roofs may exceed 35 feet in height without a conditional use permit; provided, that (1) the addition does not exceed 10 feet in height (for a maximum height of 45 feet); (2) that the allowance would be compatible with the architectural design; and (3) that the allowance would provide additional articulation that could otherwise not be achieved within the heights specified above. ca d r L_ IL N d M M r. d O CU ca U .E 7 Lt9 N O N d V C C L 0 r C d E L U M r Q Packet Pg. 192 2.c 4.1.030 The Lyons Urban 3 Ione (L-U3) %c Diagram A: Building Placement A. BuIWIR6 PIAiEIRERF. 1. PRIMARY BUILDINGS Apdroarybuildingshall be placed on slot in oompliancewlth the following requirements, within the Latched area as shown in the diagram above, unless specifiedotherwise. bytbe standards for an allowed building type in Chapter 7 (Frontage Type Standards) or Chapter 8 (Building Type Standards). Mimnmm Mac. a. Fiont Setback (]stand 2n(V 1' 5' 3rd Sony` is, Slope Overlay` 5' 15' •A reduced setback may be pemtitmd through the issuance of an A4ustruent for up to 20%, or over 20%with the approval ofa'Variance. b. Setback from Residential Zone Win mid 2nd story Rear and Side) 15' 3rd stay c. Rent and Side Setback 0' d. Side Street Setback 5' e.Rest Alley Setback O'lstswry 5'2nd story 10' 3rd story f. The 3rd Story shall not exceed 50% of the builsiing footprint. 2. ARCHITECTURALENCROACHMENTS Patios, uncovered stoops, roof overhangs, and awnings msy eucrmch S' maxmum into the requited front setback MLyons Corridor Development Code a E ge ed FI 'I Diagram B: Building Profile B. BuILMMGPROFILE AROFEMME. L HEIGHT Each structure shall comply with the following height limits. a. Mardmum height: 3 stories shall be permitted. For flat roof, the maximum height of the parapet cannot exceed 4S feet from grade and for dopLmg roof$, the maximmM height of the roof ridge cannot aced SO feet from grade Wisgram B). b. Accessory Structure: l5' maodmum to peak 2. ALLOWED FRONTAGE TYPES Only the following frontage types are allowed within the 1,U3 zone. Zhe straetfidng facade of each primary building shall be designed as one of the following frontage types, in compliance with Chapter? (FrontagsType Standuds). a. Forecourt (100' minimum lot frontage squire]) b. Stoop c. Shopfront &Awning Should aspects of a certain lot in the 1rU3 ate preclude development in aceordanca with the standards fisted above, ahernadw; frontage designs may be permitted subject to section 2.1.030.B. At the discretion of the Director, architectural treatments for flat and sloping roofs may exceed 45 feet in height without a conditional use permit; provided, that (1) the addition does not exceed five feet in height (for a maximum height of 50 feet); (2) that the allowance would be compatible with the architectural design; and (3) that the allowance would provide additional articulation that could otherwise not be achieved within the heights specified above. c :a ca d r L_ ILL N d M M M d M O CU .E 7 Ln N O N d V C C O r C d E L U r r Q Packet Pg. 193 2.c 4.1.040 The Lyons Urban tenter Zone (L-Uq sale Diagram A: Building Placement A. Bulwlx6 PLAiEAREirr. 1. PRIMARY BUILDINGS Apdma y bWldingdmU be placed on slot in ooMR=cewith the following requirements, within the hatched area as shown in the diagram above, unless specified otherwise bytbe standards for an allowed building type in Chip- 7 (Frontage Type Standards) or Chapter 8 (Building Type Standards). Mamma- Mac. a. Fkont Setback (]stand 2nd)' 1' 5' 3rd and 4th Story 10, A reduced setback may be permitted through the issuance of an Adjustment for up to 2096, or over 20% with the approval of a Variance. b. Setback from Re ddendal Zone 10 1at and 2nd story attar and Side) 15'3rd stony 20'4th story c. Rear and Side Setback 0' d. Side Street Setback 0' S' a. Rear Alley Setback O'lstswry 5'2nd story 10' 3rd and 4th awry f. The 4th Story shall not exceed 50% of the b'"R &g footprint. 2. ARCHITECTURAL ENCROACHMENTS Patios, uncovered stoops, roof ovnhangs, and awnings may encroach 5' maximum into the required front setback. aLyons Corridor Development Code E 4 dl - jle le Diagram B: Building Profile B. BuILRIIi6PROFILE ARoFROMME. 1, HEIGHT Each structure shall comply with the following height limits. 1. Maximum height: 4 stories shag be permitted. For flat roof, the maximum height of the parapet cannot exceed SS feet from grade and for doping roofs, the maoumum height of the roof ridge cannot oweed 60 feet from grade (Diagram B). 2. Accessory structum 15' mndmum to peak 2. ALLOWED FRONTAGE TYPES Only the following frontage types are allowed within the 1,UC zone. Zhe streetfidng facade of each primary buikbmg shall be designed as one of the following frontage types, in compliance with Chapter? (FrontageType Standards). a. Forecourt (100' minimum lot frontage required) b. Shopfront &Awning Should aspects of a certain lot in the 1r117C zone preclude development in accordance with the standards Rood above, alternative frontage designs may be permitted su4ect to section 2.1.030.5. At the discretion of the Director, architectural treatments for flat and sloping roofs may exceed 55 feet in height without a conditional use permit; provided, that (1) the addition does not exceed five feet in height (for a maximum height of 60 feet); (2) that the allowance would be compatible with the architectural design; and (3) that the allowance would provide additional articulation that could otherwise not be achieved within the heights specified above. Packet Pg. 194 6.1.040 Land Use Tables 2.c TABLE A: Specific Function. Allowed Land Uses and Permit Requirements for the Lyons Corridor Planning Area P Permitted Use AP Administrative Permit MUP Minor Use Permit required CUP Conditional Use Permit required X Prohibited PERMIT REQUIRED BY ZONE Land Use Types L.U1 L.U2 L.U3 L.UC Retail 25. General retail, except, with any of the following features P P P(2) P(2) Alcohol beverage sales (Over 10% shelf space) X X CUP CUP Drive -through CUP MUP MUP CUP Floor Area over 20,000 square feet X X P(2) P(2) Operating between 11:00 p.m. and 7:00 a.m. MUP MUP MUP(2) MUP(2) 26. Second Hand Stores G412 P G P P G P P G4P P 27. Thrift Stores G4p P G4p p Gljpf2) 2)G4p(2)p 28. Food Stores P P P P 29. Resturants Fast food/with drive -through CUP MUP MUP CUP Full or Limited Service or Takeout/delivery P P P P 30. Hookah Bar/Cigar Club X X CUP CUP Alcohol Consumption 31. BarandAlcohol Drinking Establishments X CUP CUP(2) CUP(2) 32. Wine Bar (Wine Sales and Wine Consumption Only) MUP MUP MUP(2) MUP(2) 33.As an accessoryto a restaurant (limited, full orfastfood) AP AP AP AP Transportation, Communications, Infrastructure 34. Parking facility, public or commercial CUP CUP MUP MUP 35. Wireless telecommunications facility Up to 35 feet high MUP MUP MUP MUP Above 35 feet high CUP CUP CUP CUP Co -located MUP MUP MUP MUP 36. Public Services, General P P P P 2) Notes: (1) Unless otherwise allowed through the issuance of a Minor Use Permit, these uses shall not be located on the first floor (2) Unless otherwise approved through the issuance of a Minor Use Permit, these uses shall be located on the first and/or second floors of structure (3) Subject to LCP development standards a) U c CU c =a L 0 c a� E U 2 Q ® Allowable Land Uses Packet Pg. 195 2.c 25. GENERAL RETAIL General Retail I Parkina Includes establishments primarily engaged in the sale of 1 space per 250 square feet goods and merchandise, but excludes those uses classified under "Retail Sales, Specific" and other use classifications in this chapter. Typical retail uses include, but are not limited to, apparel boutiques, appliance, antiques, auto parts, art supply, bakeries, butchers, bicycle, book, electronics, florists, hardware, hobby, jewelry, magazine, music, pet supply, pharmacies, sporting goods, stationary, tov. video rental, and vintage clothing stores. 26. SECOND HAND STORES Second Hand Stores I Parkina Includes establishments selling pre -owned or used items, 1 space per 250 square feet including, but not limited to, apparel, electronics, furniture and household goods, but does not include antique, coin, vintage clothing, or svortina Lyoods/memorabilia stores. Second Hand Stores are subject to the development standards in UDC Section 17.66.135. 27. THRIFT STORES Thrift Stores I Parkina Includes a shop selling secondhand goods, such as clothes, 1 space per 250 square feet, plus parking for merchandise often to benefit a charity; also called thrift shop. Thrift donation facilities stores may, but are not required to have, merchandise donation facilities. Thrift Stores are subject to the in UDC Section 17.66.135. 28. FOOD STORES Food Stores- The following are food store Parking uses: (a) Supermarket/Grocery - A retail establishment, 1 space per 250 square feet exceeding three thousand, five hundred (3,500) square feet, primarily selling food as well as other convenience and household goods and may include subordinate uses such as bakeries, delis, and take out restaurants. Alcohol sales (beer, wine, or other spirits) shall be limited to less than 10% of the shelf space for the sale of goods and shall be in accordance with the provisions of UDC Section 17.66.020 (Alcohol Sales). (b) Convenience Store - any retail establishment, up to three thousand five hundred (3,500) square feet in size, offering for sale pre -packaged food products, household items, newspapers and/or magazines, sandwiches and other pre -prepared foods for off -site consumption. Beer and wine sales shall be in accordance with the provisions of UDC Section 17.66.020 (Alcohol Sales). m Allowable Land Uses Packet Pg. 196 2.c LYONS CORRIDOR PLAN - PROPOSED AMENDMENTS Q Packet Pg. 197 4.1.010 The Lyons Urban 1 Zone (L-U1) 2.c Side Diagram A: Building Placement A. BUILDING PLACEMENT. Diagram B: Building Profile B. BUILDING PROFILE AND FRONTAGE. 1. PRIMARY BUILDINGS 1 A primary building shall be placed on a lot in compliance with the following requirements, within the hatched area as shown in the diagram above, unless specified otherwise by the standards for an allowed building type in Chapter 7 (Frontage Type Standards) or Chapter 8 (Building Type Standards). Minimum Max. a. Front Setback 1' 5' With outdoor Dinning 101, b. Setback from Residential Zone 10' 1st story (Rear and Side) 15'2nd story c. Side Setback 0' d. Side Street Setback 5' e. Rear Alley Setback 0' 1st story 5'2nd story 3. ARCHITECTURAL ENCROACHMENTS Patios, uncovered stoops, roof overhangs, and awnings may encroach 5' maximum into the required front setback (Diagram B). Outdoor dining may encroach into the front setback. 9oPng Ruch! Ard�i�cW ml Fnh.rixme�h HEIGHT Each structure shall comply with the following height limits. a. Maximum height: 2 stories shall be permitted. For flat roof development, the maximum height to parapet cannot exceed 35 feet from grade; and for sloping roofs, the maximum height of the roof ridge cannot exceed 45 feet from grade (Diagram B). At the discretion of the Director, architectural treatments for flat and sloping roofs may exceed 35 feet in height without a conditional use permit; provided, that (1) the addition does not exceed 10 feet in height (for a maximum height of 45 feet); (2) that the allowance would be compatible with the architectural design; and (3) that the allowance would provide additional articulation that could otherwise not be achieved within the heights specified above. b. Accessory structure: 15' maximum to peak. 2. ALLOWED FRONTAGE TYPES Only the following frontage types are allowed within the L-Ul zone. The streetfacing facade of each primary building shall be designed as one of the following frontage types, in compliance with Chapter 7 (Frontage Type Standards). a. Forecourt (100' minimum lot frontage required) b. Lightcourt c. Shopfront & Awning Should aspects of a certain lot in the L-Ul zone preclude development in accordance with the standards listed above, alternative frontage designs may be permitted subject to section 2.1.030.13. MLyons Corridor Development Code Packet Pg. 198 2.c 4.1.020 The Lyons Urban 2 Zone (L-U2) �1 IalL .�L JI JI �I �� RJR CI yl f all I b', 90P�19n�aa�i�cNml ce— IV I I a � Corner Lot Side Diagram A: Building Placement A. BUILDING PLACEMENT. 1. PRIMARY BUILDINGS A primary building shall be placed on a lot in compliance with the following requirements, within the hatched area as shown in the diagram above, unless specified otherwise by the standards for an allowed building type in Chapter 7 (Frontage Type Standards) or Chapter 8 (Building Type Standards). Minimum Max. a. Front Setback 1' 5' b. Setback from Residential Zone 10' 1st story (Rear and Side) 15'2nd story c. Rear and Side Setback 0' d. Side Street Setback 5' e. Rear Alley Setback 0' 1st story 5'2nd story 3. ARCHITECTURAL ENCROACHMENTS Patios, uncovered stoops, roof overhangs, and awnings may encroach 5' maximum into the required front setback (Diagram B). Outdoor dining may encroach into the front setback. Diagram B: Building Profile B. BUILDING PROFILE AND FRONTAGE. 1. HEIGHT Each structure shall comply with the following height limits. a. Maximum height: 2 stories shall be permitted. For flat roof development, the maximum height to parapet cannot exceed 35 feet from grade; and for sloping roofs, the maximum height of the roof ridge cannot exceed 45 feet from grade (Diagram B). At the discretion of the Director, architectural treatments for flat and sloping roofs may exceed 35 feet in height without a conditional use permit; provided, that (1) the addition does not exceed 10 feet in height (for a maximum height of 45 feet); (2) that the allowance would be compatible with the architectural design; and (3) that the allowance would provide additional articulation that could otherwise not be achieved within the heights specified above. b. Accessory structure: 15' maximum to peak. 2. ALLOWED FRONTAGE TYPES Only the following frontage types are allowed within the L-U2 zone. The streetfacing facade of each primary building shall be designed as one of the following frontage types, in compliance with Chapter 7 (Frontage Type Standards). a. Forecourt (100' minimum lot frontage required) b. Lightcourt c. Shopfront & Awning Should aspects of a certain lot in the L-U2 zone preclude development in accordance with the standards listed above, alternative frontage designs may be permitted subject to section 2.1.030.13. a� c =a ca d IL N d CL d O tU r- 7 2 tn N C N d c.> C ca C E O r C d E t c.> ca r Q ® Lyons Corridor Development Code Packet Pg. 199 2.c 4.1.030 The Lyons Urban 3 Zone (L-U3) I I Iwi I I I I I I I j c I I I I I I e� I I I Corner Lot Side Diagram A: Building Placement Diagram B: Building Profile 0 c A. BUILDING PLACEMENT. 1. PRIMARY BUILDINGS B. BUILDING PROFILE AND FRONTAGE. IX E A primary building shall be placed on a lot in compliance with the following 1. HEIGHT LL requirements, within the hatched area as shown in the diagram above, ' unless specified otherwise by the standards for an allowed building type Each structure shall comply with the following height limits. in Chapter 7 (Frontage Type Standards) or Chapter 8 (Building Type a. Maximum height: 3 stories shall be permitted. For flat roof, the '0 Standards). maximum height of the parapet cannot exceed 45 feet from M M Minimum Max. grade; and for sloping roofs, the maximum height of the roof a. Front Setback (1st and 2nd)* 1' 5' ridge cannot exceed 50 feet from grade (Diagram B). 0 At the discretion of the Director, architectural treatments for CU 3rd Story* 15, flat and sloping roofs may exceed 45 feet in height without a R conditional use permit; provided, that (1) the addition does sZ Slope Overlay* 5' 15' not exceed five feet in height (for a maximum height of 50 v *A reduced setback may be permitted through the issuance of an feet); (2) that the allowance would be compatible with the 0 2 Adjustment for up to 20%, or over 20% with the approval of a Variance. architectural design; and (3) that the allowance would provide additional articulation that could otherwise not be achieved L0 b. Setback from Residential Zone 10' 1st and 2nd story within the heights specified above. pv (Rear and Side) 15' 3rd story C. Rear and Side Setback 0' b. Accessory Structure: 15' maximum to peak. v 0 cC d. Side Street Setback 5' 2• ALLOWED FRONTAGE TYPES C e. Rear Alley Setback 0' 1st story i 0 5'2nd story Only the following frontage types are allowed within the L-U3 10' 3rd story zone. The streetfacing facade of each primary building shall be designed as one of the following frontage types, in compliance f. The 3rd Story shall not exceed 50°/0 of the building footprint. with Chapter 7 (Frontage Type Standards). 2. ARCHITECTURAL ENCROACHMENTS b. Forecourt (100' minimum lot frontage C.> ca Q Patios, uncovered stoops, roof overhangs, and awnings may encroach 5' required) maximum into the required front setback. C. Stoop c. Shopfront & Awning Should aspects of a certain lot in the L-U3 zone preclude development in accordance with the standards listed above, alternative frontage designs may be permitted subject to section 2.1.030.13. ® Lyons Corridor Development Code Packet Pg. 200 4.1.040 The Lyons Urban Center Zone (L-UQ 2.c j I j I I I I e� I I Corner Lot Side Diagram A: Building Placement A. BUILDING PLACEMENT. 1. PRIMARY BUILDINGS A primary building shall be placed on a lot in compliance with the following requirements, within the hatched area as shown in the diagram above, unless specified otherwise by the standards for an allowed building type in Chapter 7 (Frontage Type Standards) or Chapter 8 (Building Type Standards). Minimum Max. a. Front Setback (1st and 2nd)* 1' 5' 3rd and 4th Story 10, *A reduced setback may be permitted through the issuance of an Adjustment for up to 20%, or over 20% with the approval of a Variance. b. Setback from Residential Zone 10' 1st and 2nd story (Rear and Side) 15' 3rd story 20' 4th story c. Rear and Side Setback d. Side Street Setback 0' 0' 5' e. Rear Alley Setback 0' 1st story 5'2nd story 10' 3rd and 4th story f. The 4th Story shall not exceed 50% of the building footprint. 2. ARCHITECTURAL ENCROACHMENTS Patios, uncovered stoops, roof overhangs, and awnings may encroach 5' maximum into the required front setback. s� -%WM aa"Archrkd" Enhan—ft I Diagram B: Building Profile B. BUILDING PROFILE AND FRONTAGE. 1. HEIGHT Each structure shall comply with the following height limits. 1. Maximum height: 4 stories shall be permitted. For flat roof, the maximum height of the parapet cannot exceed 55 feet from grade; and for sloping roofs, the maximum height of the roof ridge cannot exceed 60 feet from grade (Diagram B). At the discretion of the Director, architectural treatments for flat and sloping roofs may exceed 55 feet in height without a conditional use permit; provided, that (1) the addition does not exceed five feet in height (for a maximum height of 60 feet); (2) that the allowance would be compatible with the architectural design; and (3) that the allowance would provide additional articulation that could otherwise not be achieved within the heights specified above. 2. Accessory structure: 15' maximum to peak. 2. ALLOWED FRONTAGE TYPES Only the following frontage types are allowed within the L-UC zone. The streetfacing facade of each primary building shall be designed as one of the following frontage types, in compliance with Chapter 7 (Frontage Type Standards). a. Forecourt (100' minimum lot frontage required) b. Shopfront & Awning Should aspects of a certain lot in the L-UC zone preclude development in accordance with the standards listed above, alternative frontage designs may be permitted subject to section 2.1.030.13. a� c =a ca d IL N d M d O U O L0 N C N d U C ca C Ei O r C d E t 0 cC Q MLyons Corridor Development Code Packet Pg. 201 2.c 6.1.040 Land Use Tables TABLE A: Specific Function. Allowed Land Uses and Permit Requirements for the Lyons Corridor Planning Area P Permitted Use AP Administrative Permit MUP Minor Use Permit required CUP Conditional Use Permit required X Prohibited PERMIT REQUIRED BY ZONE Land Use Types L.U1 L.U2 L.U3 L.UC Retail 25. General retail, except, with any of the following features P P P(2) P(2) Alcohol beverage sales (Over 10% shelf space) X X CUP CUP Drive -through CUP MUP MUP CUP Floor Area over 20,000 square feet X X P(2) P(2) Operating between 11:00 p.m. and 7:00 a.m. MUP MUP MUP(2) MUP(2) 26. Second Hand Stores P P P(2) P 27. Thrift Stores P P P(2) P(2) 28. Food Stores P P P P 29. Resturants Fast food/with drive -through CUP MUP MUP CUP Full or Limited Service or Takeout/delivery P P P P 30. Hookah Bar/Cigar Club X X CUP CUP Alcohol Consumption 31. BarandAlcohol Drinking Establishments X CUP CUP(2) CUP(2) 32. Wine Bar (Wine Sales and Wine Consumption Only) MUP MUP MUP(2) MUP(2) 33.As an accessoryto a restaurant (limited, full orfastfood) AP AP AP AP Transportation, Communications, Infrastructure 34. Parking facility, public or commercial CUP CUP MUP MUP 35. Wireless telecommunications facility Up to 35 feet high MUP MUP MUP MUP Above 35 feet high CUP CUP CUP CUP Co -located MUP MUP MUP MUP 36. Public Services, General P P P P Notes: (1) Unless otherwise allowed through the issuance of a Minor Use Permit, these uses shall not be located on the first floor (2) Unless otherwise approved through the issuance of a Minor Use Permit, these uses shall be located on the first and/or second floors of structure (3) Subject to LCP development standards ii a� CU a a� 0 U a .2 LO N 0 N 0 U c CU c =a L 0 c a� E U 2 Q ® Allowable Land Uses Packet Pg. 202 2.c 25. GENERAL RETAIL General Retail I Parkina Includes establishments primarily engaged in the sale of 1 space per 250 square feet goods and merchandise, but excludes those uses classified under "Retail Sales, Specific" and other use classifications in this chapter. Typical retail uses include, but are not limited to, apparel boutiques, appliance, antiques, auto parts, art supply, bakeries, butchers, bicycle, book, electronics, florists, hardware, hobby, jewelry, magazine, music, pet supply, pharmacies, sporting goods, stationary, tov. video rental. and vintage clothing stores. 26. SECOND HAND STORES Second Hand Stores I Parkina Includes establishments selling pre -owned or used items, 1 space per 250 square feet including, but not limited to, apparel, electronics, furniture and household goods, but does not include antique, coin, vintage clothing, or sporting goods/memorabilia stores. Second Hand Stores are subject to the development standards in UDC Section 17.66.135. 27. THRIFT STORES Thrift Stores I Parkina Includes a shop selling secondhand goods, such as clothes, 1 space per 250 square feet, plus parking for merchandise often to benefit a charity; also called thrift shop. Thrift donation facilities stores may, but are not required to have, merchandise donation facilities. Thrift Stores are subject to the development standards in UDC Section 17.66.135. 28. FOOD STORES Food Stores- The following are food store Parking uses: (a) Supermarket/Grocery - A retail establishment, 1 space per 250 square feet exceeding three thousand, five hundred (3,500) square feet, primarily selling food as well as other convenience and household goods and may include subordinate uses such as bakeries, delis, and take out restaurants. Alcohol sales (beer, wine, or other spirits) shall be limited to less than 10% of the shelf space for the sale of goods and shall be in accordance with the provisions of UDC Section 17.66.020 (Alcohol Sales). (b) Convenience Store - any retail establishment, up to three thousand five hundred (3,500) square feet in size, offering for sale pre -packaged food products, household items, newspapers and/or magazines, sandwiches and other pre -prepared foods for off -site consumption. Beer and wine sales shall be in accordance with the provisions of UDC Section 17.66.020 (Alcohol Sales). m Allowable Land Uses Packet Pg. 203 2.c SOLEDAD CANYON ROAD CORRIDOR PLAN — REDLINE/STRIKETHROUGH Note that new proposed language is shown in red underline and current language proposed to be removed is shown in red strikethrough. U- Q Packet Pg. 204 2.c r——— — — — — — — I a i i I L I I I I I - I I Comer Lot Side -, Diagram C: Parking Placement B. DEVELOPMENT STANDARDS dl Jyyyyyyl W e ai raj Ce 4J Maximum floor area ratio (FAR) of nonresidential uses 0.75 Maximum lot coverage 80% Maximum density (units per gross acre) 18 Minimum density (units per gross acre) N/A Maximum height of a structure without a CUP 135' Diagram B: Building Profle At the discretion of the Director, architectural treatments may exceed 35 feet in height without a CUP; provided, that (1) the addition does not exceed 10 feet in height (for a maximum height of 45 feet); (2) that the allowance would be compatible with the architectural design; and (3) that the allowance would provide additional articulation that could otherwise not be achieved within 35 feet. C. PARKING AND SERVICES 1. PARKING, SERVICES & ACCESSORY STRUCTURE PLACEMENT Off-street parking, services and accessory structures shall be placed on a lot in compliance with the following requirements, within the hatched area shown on the GENERAL P L A N diagram above. a. Street Setback: 10' minimum b. Side Street Setback: 5' minimum c. Side Yard Setback: 5' minimum d. Rear Setback: 5' minimum Policy C 7.1.6: Encourage placement of building entries in locations accessible to public sidewalks and transit. Subterranean parking may extend beyond building footprint, and may extend to a height of 3' maximum above finished grade, provided that the garage perimeter wall aligns with the face of the building. 2. PARKING REQUIREMENTS Each site shall provide off-street parking in compliance with Sections 17.41-17.49 of the UDC. D. BUILDING TYPES 1. Unless otherwise permitted through the issuance of a Minor Use Permit, only the following building types are allowed in the SC-Ul zone. Each allowed building type shall be designed in compliance with Chapter 6 (Building Type Standards). a. Commercial Pad b. Shopfront Commercial c. Commerical Block -Commercial E. ALLOWED LAND USES 1. Only a land use identified as permitted or conditionally permitted within the Community Commercial (CC) zone in Sections 17.41-17.49 of the UDC shall be established on a lot in the SC-Ul zone. W Zones and Development Sta Packet Pg. 205 2.c B. DEVELOPMENT STANDARDS Maximum density (units per gross acre) 30 Minimum density (units per gross acre) 11 Maximum floor area ratio (FAR) of nonresidential component 1.0 Minimum floor area ratio (FAR) of nonresidential component 0.25 Surface -level parking setback from major/secondary highway (in feet) 1015 Structure setback from neighboring residential zones or uses (in feet) 25 Maximum height of building/structure without a CUP (in feet) 1 50 1 At the discretion of the Director, architectural treatments may exceed 50 feet in heightwithout a CUP provided, that (1) the addition does not exceed 10 feet in height (for a maximum height of 60 feet); (2) that the allowance would be compatible with the architectural design; and (3) that the allowance would provide additional articulation that could otherwise not be achieved within 50 feet Non-residential floor area ratios and residential densities less than the minimum shall require a Minor Use Permit (UDC 17.35.010.A). Residential projects not complying with the standards above are subject to the City's regular multifamily development and parking standards and are not subject to mixed use development incentives. C. PARKING AND SERVICES 1. PARKING, SERVICES & ACCESSORY STRUCTURE PLACEMENT Off-street parking, services and accessory structures shall be placed on a lot in compliance with the following requirements, within the hatched area shown on the diagram above. a. Street Setback: 10' minimum b. Side Street Setback: 5' minimum c. Side Yard Setback: 5' minimum d. Rear Setback: 5' minimum Subterranean parking may extend beyond building footprint, and may extend to a height of 3' maximum above finished grade, provided that the garage perimeter wall aligns with the face of the building. 2. PARKING REQUIREMENTS Each site shall provide off-street parking in Diagram C: Parking Placement compliance with UDC Section 17.55.050 (for mixed use projects) or with Sections 17.41-17.49 of the UDC if the project does not qualify for mixed use incentives. D. BUILDING TYPES 1. Unless otherwise permitted through the issuance of a Minor Use Permit, only the following building types are allowed in the SC-UC zone. Each allowed building type shall be designed in compliance with Chapter 6 (Building Type Standards). a. Commercial Block Mixed Use E. ALLOWED LAND USES 1. Only a land use identified as permitted or conditionally permitted within the Mixed Use Corridor (MXC) zone in Section 17.35.010(B) of the UDC shall be established on a lot in the SC-UC zone. W Zones and Development Sta Packet Pg. 206 2.c EXHIBIT H: SOLEDAD CANYON ROAD CORRIDOR PLAN — PROPOSED AMENDMENTS Packet Pg. 207 2.c r——— — — — — — — I a i i I L I I I I I - I I Comer Lot Side -, Diagram C: Parking Placement B. DEVELOPMENT STANDARDS dl Jyyyyyyl W e ai raj Ce 4J Maximum floor area ratio (FAR) of nonresidential uses 0.75 Maximum lot coverage 80% Maximum density (units per gross acre) 18 Minimum density (units per gross acre) N/A Maximum height of a structure without a CUP 135' Diagram B: Building Profle ' At the discretion of the Director, architectural treatments may exceed 35 feet in height without a CUP; provided, that (1) the addition does not exceed 10 feet in height (for a maximum height of 45 feet); (2) that the allowance would be compatible with the architectural design; and (3) that the allowance would provide additional articulation that could otherwise not be achieved within 35 feet. C. PARKING AND SERVICES 1. PARKING, SERVICES & ACCESSORY STRUCTURE PLACEMENT Off-street parking, services and accessory structures shall be placed on a lot in compliance with the following requirements, within the hatched area shown on the GENERAL P L A N diagram above. a. Street Setback: 10' minimum b. Side Street Setback: 5' minimum c. Side Yard Setback: 5' minimum d. Rear Setback: 5' minimum Policy C 7.1.6: Encourage placement of building entries in locations accessible to public sidewalks and transit. Subterranean parking may extend beyond building footprint, and may extend to a height of 3' maximum above finished grade, provided that the garage perimeter wall aligns with the face of the building. 2. PARKING REQUIREMENTS Each site shall provide off-street parking in compliance with Sections 17.41-17.49 of the UDC. D. BUILDING TYPES 1. Unless otherwise permitted through the issuance of a Minor Use Permit, only the following building types are allowed in the SC-Ul zone. Each allowed building type shall be designed in compliance with Chapter 6 (Building Type Standards). a. Commercial Pad b. Shopfront Commercial c. Commerical Block -Commercial E. ALLOWED LAND USES 1. Only a land use identified as permitted or conditionally permitted within the Community Commercial (CC) zone in Sections 17.41-17.49 of the UDC shall be established on a lot in the SC-Ul zone. Zones and Development Sta Packet Pg. 208 2.c B. DEVELOPMENT STANDARDS Maximum density (units per gross acre) 30 Minimum density (units per gross acre) 11 Maximum floor area ratio (FAR) of nonresidential component 1.0 Minimum floor area ratio (FAR) of nonresidential component 0.25 Surface -level parking setback from major/secondary highway (in feet) 1015 Structure setback from neighboring residential zones or uses (in feet) 25 Maximum height of building/structure without a CUP (in feet) 1 50 'At the discretion of the Director, architectural treatments mayexceed 50 feet in height without a CUP provided, that (1) the addition does not exceed 10 feet in height (for a maximum height of 60 feet); (2) that the allowance would be compatible with the architectural design; and (3) that the allowance would provide additional articulation that could otherwise not be achieved within 50 feet. Non-residential floor area ratios and residential densities less than the minimum shall require a Minor Use Permit (UDC 17.35.010.A). Residential projects not complying with the standards above are subject to the City's regular multifamily development and parking standards and are not subject to mixed use development incentives. C. PARKING AND SERVICES 1. PARKING, SERVICES & ACCESSORY STRUCTURE PLACEMENT Off-street parking, services and accessory structures shall be placed on a lot in compliance with the following requirements, within the hatched area shown on the diagram above. a. Street Setback: 10' minimum b. Side Street Setback: 5' minimum c. Side Yard Setback: 5' minimum d. Rear Setback: 5' minimum Subterranean parking may extend beyond building footprint, and may extend to a height of 3' maximum above finished grade, provided that the garage perimeter wall aligns with the face of the building. 2. PARKING REQUIREMENTS Each site shall provide off-street parking in Diagram C: Parking Placement compliance with UDC Section 17.55.050 (for mixed use projects) or with Sections 17.41-17.49 of the UDC if the project does not qualify for mixed use incentives. D. BUILDING TYPES 1. Unless otherwise permitted through the issuance of a Minor Use Permit, only the following building types are allowed in the SC-UC zone. Each allowed building type shall be designed in compliance with Chapter 6 (Building Type Standards). a. Commercial Block Mixed Use E. ALLOWED LAND USES 1. Only a land use identified as permitted or conditionally permitted within the Mixed Use Corridor (MXC) zone in Section 17.35.010(B) of the UDC shall be established on a lot in the SC-UC zone. W Zones and Development Sta Packet Pg. 209