Loading...
HomeMy WebLinkAbout1997-04-08 - AGENDA REPORTS - TITLE 18 SECTION 18 02 AMEND (2)AGENDA REPORT City Manager Approval /& Item to be presented Ruben M. Barrera UNFINISHED BUSINESS DATE: SUBJECT: DEPARTMENT: BACKGROUND April 8, 1997 ADOPTION OF AMENDMENTS TO TITLE 18 OF THE SANTA CLARITA MUNICIPAL CODE - BUILDING CODE, SECTION 18.02 AMENDMENTS TO CERTAIN SECTIONS - EARTHQUAKE PROVISIONS ORDINANCE NO. 97-4 Building and Engineering Services On March 25, 1997 the City Council introduced Ordinance No. 97-4 amending the City of Santa Clarita Municipal Code and passed the matter to a second reading at tonight's meeting. The Ordinance presents all of the Building Code amendments contained in the Municipal Code. RECOMMENDATION The City Council adopt Ordinance 97-4 amending the City of Santa Clarita Municipal Code. ATTACHMENT Agenda Report dated March 25, 1997 Ordinance No. 974 JB:ce a..&cq=2jb APPROUED Agenda Item:jQ4%. AGENDA REPORT City Manager Approval Item to be presented by: Ruben M. Barrera IzIWita6.11I..1121:1 M DATE: March 25, 1997 SUBJECT: ADOPTION OF AMENDMENTS TO TITLE 18 OF THE SANTA CLARITA MUNICIPAL CODE - BUILDING CODE, SECTION 18.02 AMENDMENTS TO CERTAIN SECTIONS - EARTHQUAKE PROVISIONS ORDINANCE NO. 97-4 DEPARTMENT: Building and Engineering Services On October 22, 1996, the Building and Safety Division presented to the City Council information on possible amendments to the Building Codes regarding earthquake design provisions to improve earthquake safety. At that time, staff presented several options for possible code amendments and recommended that the City Council direct staff to prepare earthquake amendments similar to those developed by the County of Los Angeles. The City Council concurred with staff s recommendation. Staff has since conducted two public participation meetings resulting in positive industry feedback and received no opposition to the proposed amendments. These earthquake amendments will result in added building strength in resisting earthquake forces for wood frame buildings. They will also provide for construction of stronger concrete and steel frame buildings. It is estimated that these changes will add approximately $1,200-$1,500 to the cost of a new home and less than 1 percent added cost for other types of construction. Ordinance 97-4 amends Section 18.02 dealing with soils engineering, fire safety and other local building safety requirements, by repealing the section in its current form and restructuring it for editorial purposes to include the proposed earthquake provisions. RECOMMENDATION The City Council introduce Ordinance 97-4 amending the City of Santa Clarita Municipal Code, waive further reading, and pass to second reading. Ordinance No. 97-4 cwMlMq.m .d9.jhc. PUBLIC NOTICE NOTICE IS HEREBY GIVEN that on March 25, 1997, the City Council of the City of Santa Clarita introduced an ordinance entitled: AN ORDINANCE OF THE CITY OF SANTA CLARITA, CALIFORNIA, AMENDING THE MUNICIPAL CODE AT SECTION 18.02 OF TITLE 18 RELATING TO THE BUILDING CODE This ordinance relates to amendments to the Uniform Building Code and will result in added building strength in resisting earthquake forces for wood frame buildings and to provide for construction of stronger concrete and steel frame buildings. A certified copy of the complete text of the ordinance is posted and may be read in the City Clerk's Office, 23920 Valencia Boulevard, Suite 301, Santa Clarita, and/or a copy may be obtained from that office. Dated this 1st day of April, 1997. ..�. ' Sharon L. Dawson, CMC, City Clerk City of Santa Clarita STATE OF CALIFORNIA ) COUNTY OF LOS ANGELES ) CITY OF SANTA CLARITA ) Sharon L. Dawson, being first duly sworn, deposes and says that she is the duly appointed and qualified City Clerk of the City of Santa Clarita and that by Tuesday, April 1, 1997, she caused a certified copy of the subject ordinance to be posted and made available for public review in the City Clerk's office and a copy of the ordinance summary to be published as required by law. Sharon L. Dawson, CMC, City Clerk City of Santa Clarita ORDINANCE 97- 4 AN ORDINANCE OF THE CITY COUNCIL OF THE CITY OF SANTA CLARITA, CALIFORNIA, AMENDING THE MUNICIPAL CODE AT SECTION 18.02 OF TITLE 18 RELATING TO THE BUILDING CODE WHEREAS, the City of Santa Clarita is located in a region having unique geologic conditions, including known active seismic faults, and identified by the Uniform Building Code and by the State of California as a region having a high degree of seismic activity as evidenced by the 1994 Northridge Earthquake; and WHEREAS, the soil located in the region is unique in its high sulfate content and exhibits a high degree of expansivity; and WHEREAS, the climate is and in nature and the topography of the City consists of numerous canyons and hillsides thereby posing a high degree of fire hazard; and WHEREAS, the above factors justify that all of the attached amendments to the State Building Code are related to the topography, geology or climate of the City of Santa Clarita, and WHEREAS, this Ordinance repeals and re -adopts those technical local amendments dealing with specific unique conditions of this community. NOW, THEREFORE, THE CITY COUNCIL OF THE CITY OF SANTA CLARITA, CALIFORNIA, DOES ORDAIN AS FOLLOWS: SECTION 1. Section 18.02 of Title 18 of the Santa Clarita Municipal Code relating to the Building Code, is hereby repealed. SECTION 2. The Santa Clarita Municipal Code is hereby amended to add Section 18.02 - Amendments to Certain Sections, relating to the amendments to the Building Code, to read as follows: i IMMWKOAJPI AMENDMENTS TO CERTAIN SECTIONS 18.02.010 Amendments to Certain Sections The following sections of the Uniform Building Code, as adopted by Section 18.01.010 hereof, are hereby added, deleted, or amended as follows: A. Section 1503 amended. Roof covering requirements. Section 1503 of the Uniform Building Code is amended to read as follows: "Sec. 1503. The roof covering on any structure regulated by this code shall be a minimum Class - B, unless required to be Class - A per Table No. 15-A, and as classified in Section 1504. Wood shakes and shingles shall be fire retardant as defined in Section 1502. The roof -covering assembly includes the roof deck, underlayment, interlayment, insulation and covering which is assigned a roof -covering classification." B. Section 1611 amended. Anchorage of Concrete or Masonry Walls, Section 1611 of the Uniform Building Code is amended to read as follows: "Sec. 1611. Concrete or masonry walls shall be anchored to all floors, roofs and other structural elements which provide required lateral support for the wall. Such anchorage shall provide a positive direct connection capable of resisting the horizontal forces specified in this chapter or a minimum force of 300 pounds per lineal foot (4.38 kN/m) of wall, whichever is greater. Walls shall be designed to resist bending between anchors where the anchor spacing exceeds 4 feet (1220 mm). Required anchors in masonry walls of hollow units or cavity walls shall be embedded in a reinforced grouted structural element of the walls. See Sections 1630, 1631.2.8, and 1631.2.9." C. Subsection 1631.2.8 amended. Anchorage of concrete or masonry walls. Subsection 1631.2.8 of the Uniform Building Code is amended to read as follows including the addition of subsections 1631.2.8.1, 1631.2.8.2 and 1631.2.8.3: "1631.2.8. Anchorage of concrete or masonry walls. Concrete or masonry walls shall be anchored to all floors and roofs which provide lateral support for the wall. The anchorage shall provide a positive direct connection between the wall and floor or roof construction capable of resisting the horizontal forces specified in Section 1630 or Section 1610. Requirements for developing anchorage forces in diaphragms and for design of wall anchorages are given in Section 1631.2.9 below. Diaphragm deformation shall be considered in the design of the supported walls. When pilasters are present in the wall, pilasters shall be anchored to crossties. The anchorage force at the pilasters shall be computed with the assumption that the wall panels between the pilasters are supported on four sides. The following conditions shall be satisfied. 1631.2.8.1. Symmetry. Symmetry of anchorage systems is required. Non - symmetrical anchorage systems may be allowed when it can be shown that all components of forces are positively resisted as determined by calculations or tests. 1631.2.8.2. Minimum roof member size. Wood members used to develop anchorage forces to the diaphragm shall not be less than 3 -inch nominal thickness. All such members must be checked for earthquake loads as part of the wall anchorage system in addition to dead and live loads. 1631.2.8.3. Combination of anchor types. The maximum allowable combined load resisted by a combination of different types of anchors that exhibit different behavior or stiffness is not the sum of the allowable load for each anchor." D. Item 4 of subsection 1631.2 .9 amended Anchorage of concrete or masonry walls. Item 4 of subsection 1631.2.9 of the Uniform Building Code is amended to read as follows:. "4. Diaphragms supporting concrete or masonry walls shall have continuous ties or struts between diaphragm chords to distribute the anchorage forces specified in Section 1631.2.8. The spacing of the continuous ties shall not exceed 24 feet (7315 mm). Added chords may be used to form subdiaphragms to transmit the anchorage forces to the continuous crossties. The maximum diaphragm shear used to determine the depth of the subdiaphragm shall be 250 pounds per foot (3.65 Min)." E. Subsection 1631.2 .9 amended Anchorage of concrete or masonry walls Subsection 1631.2.9 of the Uniform Building Code is amended by adding Items 8 and 9 as follows: "8. The steel elements of the wall anchorage system shall be designed by the allowable stress design method using a load factor of 1.7. Strength design, using a load factor of 1.7 for earthquake loading, shall be used for design of embedments in concrete. 9. When designing the diaphragm to comply with the requirements stated above, the return walls and fins/canopies at entrances shall be considered. Seismic design of return walls and fins/canopies at entrances shall ensure deflection compatibility with the diaphragm by either seismically isolating the element or attaching the element and integrating its load into the diaphragm." F. Table 16-0 amended. Horizontal Force Factor, P. Note 3 of Table 16-0 of the Uniform Building Code is amended to read as follows: "3. Where flexible diaphragms, as defined in Section 1628.6, provide lateral support for walls and partitions of masonry and concrete, the value of CP for anchorage shall be increased 50 percent." G. Section 1803.3 added. Soils Containing Sulfates. Section 1803.3 added to the Uniform Building Code to read as follows: "1803.3 - Soils Containing Sulfates. Foundations for structures resting on soils containing sulfates shall require special design consideration. (See also Sections 1905.2, 1804.6 and 1806.11 )" H. Section 1804.6 added. Soils Containing Sulfates. Subsections 1804.6 and 1804.7 are renumbered to 1804.7 and 1804.8 and a new subsection 1804.6 is added to read: "1804.6 - Soils Containing Sulfates. In soils containing sulfates, the Building Official may require that special provisions be made in the foundation design and construction to safeguard against damage due to salt weathering. The Building Official may require a special investigation and report to provide this design and construction criteria." I. Section 180610 added Foundation on Expansive Soil Section 1806.10 is added to read as follows: "1806.10 -Foundations on Expansive Soil. Foundation systems on expansive soil shall be constructed in a manner that will minimize damage to the structure from movement of the soil. Slab -on -grade and mat -type footings for buildings located on expansive soils may be designed in accordance with the provisions of Division III or such other engineering design based upon geotechnical recommendation as approved by the Building Official. For residential -type buildings, where such an approved method of construction is not provided, foundations and floor slabs shall comply with the following requirements: 1. Depth of foundations below the natural and finish grades shall be not less than 24 inches for exterior and 18 inches for interior foundations. 2. Exterior walls and interior bearing walls shall be supported on continuous foundations. 3. Foundations shall be reinforced with at least two continuous one -half-inch diameter deformed reinforcing bars. One bar shall be placed within four inches of the bottom of the foundation and one within four inches of the top of the foundation. 4. Concrete floor slabs on grade shall be cast on a four -inch fill of coarse aggregate or on a moisture barrier membrane. The slabs shall be at least three and one-half inches thick and shall be reinforced with welded wire mesh or deformed reinforcing bars. Welded wire mesh shall have a cross-sectional area of not less than five -hundredths square inch per foot each way. Reinforcing bars shall have a diameter of not less than three-eighths (3/s) inch and be spaced at intervals not exceeding 24 inches each way. 5. The soil below an interior concrete slab shall be saturated with moisture to a depth of 18 inches prior to casting the concrete." J. Rection 180611 added Foundations on Soils Containing Sulfates. Section 1806.11 is added to read as follows: "1806.11- Foundations on Soils Containing Sulfates: Foundations systems on soils containing sulfates shall be constructed in a manner that will minimize damage to the structure from salt weathering. Slab -on -grade footings for buildings located on soils containing sulfates may be designed in accordance with engineering design based upon geotechnical recommendations as approved by the Building Official. For residential -type buildings, where such an approved method of construction is not provided, foundation and floor slabs shall comply with the requirements specified under Section 1806.10, items 1, 2, 3 and 4." K. Subsection 1909.3.4.2 deleted. Design Strength of Concrete: Subsection 1909.3.4.2 of the Uniform Building Code is deleted in its entirety. L. Subsection 1910.8.4 amended. Limits of Section: Subsection 1910.8.4 of the Uniform Building Code is amended to read as follows: "1910.8.4. Limits of section. For a compression member with a cross section larger than required by considerations of loading, it shall be permitted to base the minimum reinforcement and design strength on a reduced effective area Ag not less than one-half the total area. This provision shall not apply in Seismic Zones 3 and 4." M. Subsection 19217 amended Frame Members Not Part of the Lateral - Force Resisting System. Subsection 1921.7 of the Uniform Building Code is amended to read as follows: "1921.7. Frame Members Not Part of the Lateral -Force Resisting System. 1921.7.1. Frame members assumed not to contribute to lateral resistance shall be detailed according to Section 1921.7.2 or 1921.7.3 depending on the magnitude of moments induced in those members when subjected to 3 (Rw/8) times the displacements resulting from the specified lateral forces in conformance with the requirements of Section 1631.2.4. When induced moments under lateral displacements are not calculated, Section 1921.7.3 shall apply. 1921.7.2. When the induced moments and shears under lateral displacements of Section 1921.7.1 combined with the factored gravity moments and shear loads do not exceed the design moment and shear strength of the frame member, the following conditions shall be satisfied. For this purpose the load combinations (1.4D+1.4L) and 0.9D shall be used. 1921.7.2.1. Members with factored gravity axial forces not exceeding (Agf/10), shall satisfy Section 1921.3.2.1. Stirrups shall be placed at not more than d/2 throughout the length of the member. 1921.7.2.2. Members with factored gravity axial forces exceeding (Agf/10), but not exceeding 0.3P. shall satisfy Sections 1921.4.3, 1921.4.4.1 item 3, and 1921.4.4.3. Design shear strength shall not be less than the shear associated with the development of nominal moment strengths of the member at each end of the clear span. The maximum longitudinal spacing of ties shall be so for the full column height. The spacing S, shall not be more than (1) 6 diameters of the smallest longitudinal bar enclosed, (2) 16 tie -bar diameters, (3) one-half the least cross-sectional dimension of the column and (4) 6 inches (152 mm). 1921.7.2.3. Members with factored gravity axial forces exceeding 0.3P shall satisfy Sections 1921.4.4 and 1921.4.5. 1921.7.3. When the induced moments under lateral displacements of Section 1921.7.1 exceed the design moment strength of the frame member or where induced moments are not calculated, the following conditions in Sections 1921.7.3.1 through 1921.7.3.3 shall be satisfied. 1921.7.3.1. Materials shall satisfy Sections 1921.2.4, 1921.2.5 and 1921.2.6. 1921.7.3.2. Members with factored gravity axial forces not exceeding (Agf/10) shall satisfy Sections 1921.3.2.1 and 1921.3.4. Stirrups shall be placed at not more than d/2 throughout the length of the member. 1921.7.3.3. Members with factored gravity axial forces exceeding (Agf/10) shall satisfy Sections 1921.4.4, 1921.4.5 and 1921.5.2.1. 1921.7.4. Ties at anchor bolts. Additional ties which engage at least four vertical column bars shall be provided around anchor bolts which are set in the top of a column. Such ties shall be within 5 inches (127 nun) of the top of the column and shall consist of two No. 4 or three No. 3 bars." N. Subsection 2211.7.1.2 deleted. Connection Strength. Subsection 2211.7.1.2 of the Uniform Building Code is deleted in its entirety. O. Subsection 2211.7.1.3 amended. Alternate Connection, Subsection 2211.7.1.3 of the Uniform Building Code is amended to read as follows: "2211.7.1.3. Connection strength. Connection configurations utilizing welds or high- strength bolts may be used if they are shown by approved cyclic test results or calculation to develop the strength criteria in Section 2211.7.1.1 considering the effects of steel overstrength and strain hardening and to demonstrate an inelastic rotational capacity compatible with the type of moment frame structural system used in the design. FYb as used in Section 2211.7.5 shall include the effects of overstrength and strain hardening." P. Subsection 2314.1 amended. General. Subsection 2314.1 of the Uniform Building Code is amended to read as follows: "2314.1. General. Lumber, wood structural panel, and particle board diaphragms may be used to resist horizontal forces in horizontal and vertical distributing or resisting elements, provided the deflection in the plane of the diaphragm, as determined by calculations, tests or analogies drawn therefrom, does not exceed the permissible deflection of attached distributing or resisting elements. See U.B.C. Standard No. 23-2 for a method of calculating the deflection of a blocked wood structural panel diaphragm. Permissible deflection shall be that deflection up to which the diaphragm and any attached distributing or resisting element will maintain its structural integrity under assumed load conditions, i.e., continue to support assumed loads without danger to occupants of the structure. Connections and anchorages capable of resisting the design forces shall be provided between the diaphragms and the resisting elements. Openings in diaphragms which materially affect their strength shall be fully detailed on the plans and shall have their edges adequately reinforced to transfer all shearing stresses. Size and shape of diaphragms shall be limited as set forth in Table No. 23 -I -I. In the City of Santa Clarita, lumber, plywood and particle board diaphragms shall not be considered as transmitting lateral forces by rotation. EXCEPTION: One-story, attached or detached residential garages or similar non - habitable wood -framed structures with a maximum depth normal to the open side of 25 feet (7620 mm) and a maximum width of 25 feet (7620 mm). Diaphragm sheathing nails or other approved sheathing connectors shall be driven flush but shall not fracture the surface of the sheathing." Q. Section 2314 amended Wood Shear Walls and Diaphragms Section 2314 of the Uniform Building Code is amended by adding Subsections 2314.5.6 and 2314.5.7 to read as follows: "2314.5.6. Hold-down connectors. Hold-down connectors shall be designed to resist shear wall overturning moments using approved cyclic load values or 75 percent of the allowable earthquake load values that do not consider cyclic loading of the product. Connector bolts into wood framing require approved plate washers. Hold-downs shall be tightened just prior to covering the wall framing. 2314.5.7. Shear wall sill plates. Sill plates supporting shear walls with lateral loads greater than 300 pounds/foot (4.38 Min) require a 3 -inch nominal or greater thickness and shall be designed to transfer the loading to the framing or foundation below. Foundation anchor bolts in such walls shall have an approved plate washer under each nut. The nuts shall be tightened just prior to covering the wall framing." R. Subsection 2326.11.3 amended. Bracing. Subsection 2326.11.3 of the Uniform Building Code is amended to read as follows: "2326.11.3: Bracing. Braced wall lines shall consist of braced wall panels which meet the requirements for location, type, and amount of bracing specified in Table 23 -I -W and are in line or offset from each other by not more than 4 feet (1219 nun). Braced wall panels shall start at not more than 8 feet (2438 mm) from each end of a braced wall line. All braced wall panels shall be clearly indicated on the plans. Construction of braced wall panels shall be by one of the following methods: 1. Wood structural panel sheathing with a thickness not less than 3/8 inch (9.5 mm) in accordance with Tables 23 -I -M -I and 23 -I -N-1. 2. Portland cement plaster on studs spaced 16 inches (406 mm) on center installed in accordance with Table 25-I. For method 1, each braced wall panel must be at least 48 inches (1219 mm) in length, covering three stud spaced where studs are spaced 16 inches (406 mm) apart and covering two stud spaces where studs are spaced 24 inches (610 mm) apart. For method 2, the braced panel must be at last 96 inches (2438 mm) in length. All vertical joints of panel sheathing shall occur over studs. Horizontal joints shall occur over blocking equal in size to the studding except where waived by the installation requirements for the specific sheathing material. Braced wall panel sole plates shall be nailed to the floor framing and top plates shall be connected to the framing above in accordance with Table 23 -I -Q. Sills shall be bolted to the foundation or slab in accordance with Section 1806.6: Where joists are perpendicular to braced wall lines above, blocking shall be provided under and in line with the braced wall panels." S. Subsection 2326.11.4 deleted. Alternate Braced Wall Panels, Subsection 2326.11.4 of the Uniform Building Code is deleted in its entirety. T. Table 23-I-1 amended Maximum Diaphragm Dimension Ratios Table 234-I of the Uniform Building Code is amended to read as follows: TABLE 23-I-1— MAXIMtJM DIAPHRAGM DIMENSION RATIOS MATERIAL HORIZONTAL DIAPHRAGMS VERTICAL DIAPHRAGMS Maximum Maximum Span -Width Height -Width Ratios Ratios 1. Diagonal sheathing, conventional .3:1 --- 2. Diagonal sheathing, special 4:1 2:1 3. Wood structural panels nailed all edges 4:1 2:1 4. Wood structural panels blocking omitted at intermediate joints 4:1 --- Ill U. Table 23 -I -K-1 amended. Allowable shear for wind or seismic forces. Table 23 -I -K-1 of the Uniform Building Code is amended to read as follows: TABLE 23 -I -K-1 —ALLOWABLE SHEAR FOR WIND OR SEISMIC FORCES IN POUNDS PER FOOT FOR WOOD STRUCTURAL PANEL SHEAR WALLS WITH FRAMING OF DOUGLAS FIR -LARCH OR SOUTHERN PINE 1, 2, S PANEL GRADE 3,4INIMUM NOMINAL PANEL THICKNESS (Inches) MINIMUM NAIL PENETRATION IN FRAhIING (Inches) NAIL SIZE (Common or Galvanized Box) PANELS APPLIED DIRECT TO FRAMING X 25.4 for mm Nail Spacing at Plywood X 25.4 for mm 14 3 z 6 1 12 X 0.0146 for N/mm STRUCTURAL 1 6d 8d 3/8 1 Ys 8d 170 270 345 455 7/16 15'2 8d 190 295 375 500 15/32 1 Y2 8d 210 320 410 550 15/32 1518 10d 235 380 500 650 C -D, C -C 6d 8 STRUCTURAL Il, 3/8 1114 6d 150 225 290 380 8d plywood panel 3/8 1 V. 8d 165 240 305 395 siding and other covered in 7/16 I v2 sa Iso 260 335 435 grades U.B.C. Standard 23-2 or 23-3 15/32 I'h 8d 200 285 370 480 15/32 15/8 10d 230 345 450 580 --- --- --- --- --- 19/32 1518 10d 255 380 500 650 NAIL SIZE (Galvanized Casing) Plywood panel siding in grades covered in U.B.C. Standard 23- 2 3/8 1 t/2 Sd 120 180 230 305 I1 All panel edges backed with 2 -inch (51 mm) nominal or thicker framing. Panels installed either horizontally or vertically. Space nails at 6 inches (152 mm) on center along intermediate framing members for 3/8 -inch (9.5 nun) and 7/16 -inch (11 mm) panels installed on studs spaced 24 inches (610 mm) on center and 12 inches (305 nun) on center for other conditions and panel thicknesses. These values are for short -time loads due to wind or earthquake and must be reduced 25 percent for normal loading. Allowable shear values for nails in framing members of other species set forth in Table 23 -III -FF of Division III shall be calculated for all other grades by multiplying the shear capacities for nails in STRUCTURAL I by the following factors: 0.82 for species with specific gravity greater than or equal to 0.42 but less than 0.49, and 0.65 for species with a specific gravity of less than 0.42. 2. Where panels are applied on both faces of await and nail spacing is less than 6 inches (152 mm) on center on either side, panel joints shall be offset to fall on different framing members or framing shall be 3 -inch (76 mm) nominal or thicker and nails on each side shall be staggered. Framing at adjoining panel edges shall be 3 -inch (76 nun) nominal or thicker and nails shall be staggered where nails are spaced 2 inches (52 mm) on center. 4. Framing at adjoining panel edges shall be 3 -inch (76 mm) nominal or thicker and nails shall be staggered where 10d nails having penetration into framing of mor than 15/8 inches (41 mm) are spaced 3 inches (76 mm) or less on center. Shear panel assemblies designed to resist more than 300 pounds per foot (4.38 kn/m) shall have 3 -inch (76 mm) nominal or thicker sill plates and nails shall be placed not less than 1/2 -inch (13 mm) from the panel edges and not less than 3/8 -inch (9.5 mm) from the edge of the connecting members. V. Table 23-1-K-2 deleted. Allowable Shear for Wind or Seismic Forces in Pounds per Foot for Particle Board Shear Walls with Framing of Douglas Fir -Larch or Southern Pine. Table 23 -I -K-2 of the Uniform Building Code is deleted in its entirety. 12 W. Table 23 -I -W amended. Braced Wall Panels. Table 23 -I -W of the Uniform Building Code is amended to read as follows: TABLE 23 -I -W -- WALL BRACING 1. This table specifies minimumrequirements for braced panels which form interior or exterior braced wall lines. 2. See Section 2326.11.3 for full description. 3. Building length is the dimension parallel to the braced wall length X. Subsection 3102.4.3 amended. Reinforcing and Seismic Anchoraze. Subsection 3102.4.3 of the Uniform Building Code is amended to read as follows: 3102.4.3 Reinforcing and Seismic Anchorage. Every element of a masonry or concrete chimney, flue, fireplace or barbecue that extends 6 feet (1829 mm) or more above grade or that is part of a building shall be designed and constructed in accordance with Chapters 16, 18, 19, 21, and 22. Y. Subsection 2513.4 amended. Height -to -Length Ratio. Subsection 2513.4 of the Uniform Building Code is amended to read as follows: 2513.4. Height -to -Length Ratio. The maximum allowable height -to -length ratio for the construction in this Section shall be 2 to 1. Wall sections having height -to -length ratios in excess of 1 '/2 to 1 shall be blocked. All shear walls designed to resist seismic loads in the City of Santa Clarita shall have a maximum allowable height -to -length ratio of 1 to 1. 13 CONSTRUCTION METHOD BRACED PANEL CONDITION LOCATION 1 2 AND LENGTH (plywood) (stucco) One story, or Top of Two X Each end and not more than 25 feet Story (7620 mm) on center but not less than 25% of wall length One Story or Top of Two Story X Each end and not more than 25 feet (7620 mm) on center but not less than 50% of wall length First Story of Two Story X Each end and not more than 25 feet (7620 mm) on center but not less than 50% of wall length 1. This table specifies minimumrequirements for braced panels which form interior or exterior braced wall lines. 2. See Section 2326.11.3 for full description. 3. Building length is the dimension parallel to the braced wall length X. Subsection 3102.4.3 amended. Reinforcing and Seismic Anchoraze. Subsection 3102.4.3 of the Uniform Building Code is amended to read as follows: 3102.4.3 Reinforcing and Seismic Anchorage. Every element of a masonry or concrete chimney, flue, fireplace or barbecue that extends 6 feet (1829 mm) or more above grade or that is part of a building shall be designed and constructed in accordance with Chapters 16, 18, 19, 21, and 22. Y. Subsection 2513.4 amended. Height -to -Length Ratio. Subsection 2513.4 of the Uniform Building Code is amended to read as follows: 2513.4. Height -to -Length Ratio. The maximum allowable height -to -length ratio for the construction in this Section shall be 2 to 1. Wall sections having height -to -length ratios in excess of 1 '/2 to 1 shall be blocked. All shear walls designed to resist seismic loads in the City of Santa Clarita shall have a maximum allowable height -to -length ratio of 1 to 1. 13 Z. Table 25-I amended. Allowable Shear for Wind or Seismic Forces in Pounds tier Foot for Vertical Diaphragms of Lath and Plaster or Gypsum Board Frame Wall Assemblies. Table 25-I of the Uniform Building Code is amended to read as follows: TABLE 25-I — ALLOWABLE SI MAR FOR WIND OR SEISMIC FORCES IN POUNDS PER FOOT FOR VERTICAL DIAPHRAGMS OF LATH AND PLASTER OR GYPSUM BOARD FRAME WALL ASSEMBLIES ( 1,5,6) TYPE OF MATERIAL THICKNESS OF MATERIAL WALL CONSTRUCTION NAIL SPACING MAXIMUM SMEAR VALUE MINIMUM NAIL SIZE X 14.6 for N/m X 25.4 for mm x 25.4 for mm Seismic Wind X 25.4 for mm 1.. Expanded metal, or woven wire lath - and 7/8" Unblocked 6 90 180 No. 11 gage, l ''/z' long, 7/16" head, galvanized and be furred a minimum of 1/4" No. 16 gage 2. Gypsum lath 3/8" lath and 1/2" plaster Unblocked 5 30 100 No. 13 gage, 1 1/8" long, 19/64" head, plasterboard blued nail 3. Gypsum wallboard or veneer base 2/2" x 2'x 8' !4" x 4' Y2" x 4' Unblocked Blocked Unblocked 4 4 7 30 30 30 75 175 100 No. 11 gage, 13/4" long, 7/16" head, diamond - point, galvanized 4. Gypsum wallboard or veneer base Unblocked 7 30 100 5d cooler or wallboard 4 1 30 125 Blocked 7 30 125 4 30 150 5/8" Unblocked 7 30 115 6d cooler or wallboard 4 30 145 Blocked 7 30 145 4 30 175 Blocked Two ply Base ply: 9 Face ply: 7 30 250 Base ply - 6d cooler or wall board Face ply - 8d cooler or wallboard 14 1. These vertical diaphragms shall not be used to resist loads imposed by masonry or concrete construction. See Section 2513.2. Values shown are for short-term loading due to wind. Values shown must be reduced 25 percent for normal loading. 2. Applies to nailing at all studs, top and bottom plates and blocking, 3. Alternate nails may be used if their dimensions are not less than the specified dimensions. 4. For properties of cooler or wallboard nails, see Section 2340.1.2. 5. This construction shall not be used below the top level of wood construction in a multi -leveled building. 6. This maximum height to length ratio for shear walls constructed of these materials shall not exceed one to one (1:1). 7. Self -furring lath attached with staples may be permitted for non-structural application only. AA. Section 1022 added. 'Building Security." Section 1022 is hereby added to read as follows: Section 1022 -.Building Security 1022.1. Purpose. The purpose of this section is to provide a nominal level of resistance to unlawful entry. 1022.2. Scope. The provisions of this section shall apply to enclosed Group B, F, M and R Occupancies and enclosed private garages. 1022.3. Limitations. No provisions of this chapter shall require or be construed to require devices on exit doors or on sleeping room emergency exits contrary to the requirements specified in Chapter 10 and Section 310.4. 1022.4. Alternate Security Provisions. The provisions of this chapter are not intended to prevent the use of any device or method of construction not specifically prescribed by this code when such alternate provides equivalent security. 1022.5. Definitions. For the purpose of this section, certain terms are defined as follows: CYLINDER GUARD is a protective metal device of hardened steel or with a hardened steel insert that covers or surrounds the exposed portion of the lock cylinder for the purpose of protecting the cylinder from wrenching, prying, cutting, driving through, or pulling out by attack tools. DEAD BOLT is a bold which has no automatic spring action and which is operated by a key cylinder, thumbturn or lever, and is positively held fast when in the projected position. DEADLOCKING LATCH is a latch in which the latch bolt is positively held in the projected position by a guard bolt, plunger or auxiliary mechanism. LATCH is a device for automatically retaining the door in a closed position upon its closing. 15 1022.6. TESTS. 1022.6.1 Sliding Glass Doors. Panels shall be closed and locked. Tests shall be performed in the following order: 1. Test A. With the panels in the normal position, a concentrated load of 300 pounds shall be applied separately to each vertical pull stile incorporating a locking device, at a point on the stile within six inches of the locking device, in the direction parallel to the plane of glass that would tend to open the door. 2. Test B. Repeat Test A while simultaneously adding a concentrated load of 150 pounds to the same area of the same stile in a direction perpendicular to the plane of glass toward the interior side of the door. 3. Test C. Repeat Test B with the 150 -pound force in the reversed direction toward the exterior side of the door. 4. Test D, E, and F. Repeat Tests A, B and C with the movable panel lifted upwards to its full limit within the confines of the door frame. 5. Identification. Sliding glass door assemblages subject to the provisions of this section shall bear a label or other approved means of identification indicating compliance with these tests. The label shall be a type authorized through a recognized testing agency which provides periodic follow-up inspection service. 1022.6.2 Sliding Glass Windows. Sash shall be closed and locked. Tests shall be performed in the following order: 1. Test A. With the sliding sash in the normal position, a concentrated load of 150 pounds shall be applied separately to each sash member incorporating a locking device, at a point on the sash member within six inches of the locking device, in the direction parallel to the plane of glass that would tend to open the window. 2. Test B. Repeat Test A while simultaneously adding a concentrated load of 75 pounds to the same area of the same sash member in the direction perpendicular to the plan of glass toward the interior side of the window. 3. Test C. Repeat Test B with the 75 pounds of force in the reversed direction toward the exterior side of the window. 4. Test D, E and F. Repeat Tests A, B and C with the movable sash lifted upwards to its full limit within the confines of the window frame. 5. Identification. Sliding glass window assemblages subjects to the provisions of this section shall bear a label or other approved means of identification indicating compliance with these tests. The label shall be a type authorized through a recognized testing agency which provides periodic follow-up inspection service. 1022.7 DOORS 1022.7.1 General: A door forming a part of the enclosure of a dwelling unit or of an area occupied by one tenant of a building shall be constructed, installed, and secured as set forth in Sub -Sections 1022.7.2,1022.7.4, and 1022.7.5 when such door is directly reachable or capable of being reached from a street, highway, yard, court, passageway, corridor, balcony, patio, 16 breezeway, private garage, portion of the building which is available for use by the public or other tenants, or similar area. In residential occupancies, all entry doors to dwelling units or guest rooms shall be arranged so that the occupant has a view of the area immediately outside the door without opening the door. Such view may be provided by a door viewer, through windows located in the vicinity of the door, or through view ports in the door or adjoining wall. Such windows or view ports shall be constructed in compliance with the provisions of Section 1022.8. A door enclosing a private garage with an interior opening leading directly to a dwelling unit shall also comply with said Section 1022.7.2, 1022.7.3, 1022.7.4, 1022.7.5. 1022.7.2.1. Swinging Doors. Swinging wooden doors which are openable from the inside without the use of a key shall be one of the following constructions or shall be of a construction having equivalent forced -entry resistance: 1. Solid core doors not less than 13/8 inches in thickness. 2. Wood panel -type doors with panels fabricated of lumber not less than 9/16 inch thickness, provided shaped portions of the panels are not less than 1/4 inch thick. Individual panels shall not exceed 300 square inches in area. Stiles and rails shall be of solid lumber with overall dimensions of not less than 1 3/8 inches in thickness and 3 inches in width. Mullions shall be considered a part of adjacent panels unless sized as required herein for stiles and rails except mullions not over 18 inches long may have an overall width of not less than 2 inches. Carved areas shall have a thickness of not less than 3/8 inches. Dimensional tolerance published in recognized industry standards may be utilized. 3. Hollow -core doors or doors less than 13/8 inches in thickness either of which are covered on the side face with 16 -gauge sheet metal attached with screws at 6 inches maximum centers around the perimeter. Lights in doors shall be as set forth in Sections 1022.8. 1022.7.2.1 A single swinging door, the active leaf of a pair of doors, and the bottom leaf of Dutch doors shall be equipped with a dead bolt and a latch. If a key -locking feature is incorporated in the latching mechanism, a dead latch shall be used. The dead bolt and latch may be activated by one lock or by individual locks. Dead bolts shall contain hardened inserts, or equivalent, so as to repel cutting tool attack. The dead bolt lock or locks shall be key operated from the exterior side of the door and engaged or disengaged from the interior side of the door by a device not requiring a key, tool or excessive force. EXCEPTIONS: 1. The latch may be omitted from doors in Group B F, or M Occupancies. 2. In other than residential occupancies, locks may be key, or otherwise operated from the inside when not prohibited by Chapter 10 or other laws and regulations. 3. A swinging door of width greater than 5 feet may be secured as set forth in Section 1022.7.2.3. 4. In residential occupancies, doors not required by Section 310.4 or 1004 may be equipped with security -type hardware which requires a key to release from the interior side of the door if the sleeping rooms are protected with a fire -warning system as set forth in Section 310.9. A straight dead bolt shall have a minimum throw of 1 inch and the embedment shall be not less than 5/8 inch into the holding device receiving the projected bolt. A hook shape or expanding lug dead bolt shall have a minimum throw of 3/4 inch. All dead bolts or locks which 17 automatically activate two or more dead bolts shall embed at lease'/2 inch, but need not exceed 3/4 inch, into the holding devices receiving the projected bolts. 1022.7.2.3 The inactive leaf of a pair of doors and the upper leaf of Dutch doors shall be equipped with a dead bolt or dead bolts as set forth in Subsection 1022.7.2.2 EXCEPTIONS: 1. The bolt or bolts need not be key operated, but shall not be otherwise activated, from the exterior side of the door. 2. The bolt or bolts may be engaged or disengaged automatically with the dead bolt or by another device on the active leaf or lower leaf. 3. Manually -operated hardened bolts at the top and bottom of the leaf and which embed a minimum of 1/2 inch into the device receiving the projected bolt may be used when not prohibited by Chapter 10 or other laws and regulations. 1022.7.2.4 Door stops on wooden jambs for in -swinging doors shall be of one- piece construction with the jamb or joined by a rabbet. 1022.7.2.5 Nonremovable pins shall be used in pin -type hinges which are accessible from the outside when the door is closed. 1022.7.2.6 Cylinder guards shall be installed on cylinder locks for dead bolts whenever the cylinder projects beyond the outside face of the door or is otherwise accessible to attack tools. 1022.7.3. Sliding Glass Doors. Sliding glass doors shall be equipped with locking devices and shall be so installed that, when subjected to tests specified in Section 1022.6, remain intact and engaged. Movable panels shall not be rendered easily openable or removable from the frame during or after the test. Cylinder guards shall be installed on all mortise or rim -type cylinder locks installed in hollow -metal doors whenever the cylinder projects beyond the face of the door or is otherwise accessible to gripping tools. Locking devices installed on sliding glass doors providing the exit required by Section 1003 or providing for the emergency escape or rescue required by Section 310.4 shall be releasable from the inside without the use of a key, tool or excessive force. 1022.7.4. Overhead and Sliding Doors. Metal or wooden overhead and sliding doors shall be secured with a dead bolt lock, padlock with a hardened steel shackle,. or equivalent when not otherwise locked by electric power operation. Locking devices, when installed at the jamb of metal or wooden overhead doors, shall be installed on both jambs when such doors exceed 9 feet in width. Metal or wooden sliding doors exceeding 9 feet in width and provided with a jamb -locking device shall have the door side opposite the lock restrained by a guide or retainer. Cylinder guards shall be installed on all mortise or rim -type cylinder locks installed in hollow -metal doors whenever the cylinder projects beyond the face of the door or is otherwise accessible to gripping tools. fL 1022.7.5. Metal Accordion Grate or Grille -Type Doors. Metal accordion grate or grille -type doors shall be equipped with metal guides at top and bottom, and a cylinder lock or padlock and hardened steel shackle shall be provided. Cylinder guards shall be installed on all mortise or rim -type cylinder locks installed in hollow -metal doors whenever the cylinder projects beyond the face of the door or is otherwise accessible to gripping tools. 1022.8. LIGHTS 1022.8.1 General. A window, skylight or other light forming apart of the enclosure of a dwelling unit or of an area occupied by one tenant of a building shall be constructed, installed and secured as set forth in Sections 1022.8.3, when the bottom of such window, skylight or fight is not more than 16 feet above the grade of a street, highway, yard, court, passageway, corridor, balcony, patio, breezeway, private garage, portion of the building which is available for use by the public or other tenants, or similar area. A window enclosing a private garage with an exterior opening leading directly to a dwelling unit shall also comply with said Sections 1023.8.3. 1023.8.2. Material. Lights within 40 inches of a required locking device on a door when in the closed and locked position and openable from the inside without the use of a key, and lights with a least dimension greater than 6 inches but less than 48 inches in Group B, F or M Occupancies, shall be fully tempered glass, laminated glass of at least 1/4 inch thickness, approved burglary -resistant material, or guarded by metal bars, screens or grilles in an approved manner. 1022.8.3 Locking Devices 1022.8.3.1. Locking devices installed on windows providing the emergency egress required by Section 310.4 shall be releasable from the inside without the use of a key, tool or excessive force. 1022.8.3.2 Sliding glass windows shall be provided with locking devices that, when subject to the tests specified in Section 1023.6, remain intact and engaged. Movable panels shall not be rendered easily openable or removable from the frame during or after the tests. 1022.8.3.3 Other openable windows shall be provided with substantial locking devices which render the building as secure as the devices required by this section. In Group B, F, and M Occupancies, such devices shall be a glide bar, cross bar, and/or padlock with a hardened steel shackle. 1022.8.3.4 Special louvered windows, except those above the first story in Group R Occupancies which cannot be reached without a ladder, shall be of material or guarded as specified in Section 1022.14 and individual panes shall be securely fastened by mechanical fasteners requiring a tool for removal and not accessible from the outside when the window is in the closed position. 19 1022.9 Other Openings 1022.9.1. General. Openings, other than doors or lights, which form a part of the enclosure, or portion thereof, housing a single occupant and the bottom of which is not more than 16 feet above the grade of a street, highway, yard, court, passageway, corridor, balcony, patio, breezeway or similar area, or from a private garage, or from a portion of the building which is occupied, used or available for use by the public or other tenants, or an opening enclosing a private garage attached to a dwelling unit which openings therein shall be constructed, installed and secured as set forth in Section 1022.9.2. 1022.9.2 Hatchways, Scuttles and Similar Openings 1022.9.2.1. Wooden hatchways less than 1 3/4 -inch -thick solid wood shall be covered on the inside with 16 -gauge sheet metal attached with screws at 6 inch maximum centers around perimeter. 1022.9.2.2 The hatchway shall be secured from the inside with a slide bar, slide bolt, and/or padlock with a hardened steel shackle. 1022.9.2.3 Outside pin -type hinges shall be provided with nonremovable pins or a means by which the door cannot be opened through removal of hinge pins while the door is in the closed position. 1022.9.2.4 Other openings exceeding 96 square inches with a least dimension exceeding 8 inches shall be secured by metal bars, screens or grilles in an approved manner. BB. Section 3406.2 of Appendix Chapter 34, Division I amended. Effective Date. Section 3406.2 of the Appendix Chapter 34, Division I of the Uniform Building Code is hereby amended to read as follows: 113406.2 - Effective Date. Within six months of the effective date on an order issued by the Building Official or at the time work is performed on a building which requires a building permit, the building shall be brought into compliance with the provision of this Division." CC. Section 406.1 of Appendix Chapter 4, Division I amended. Outdoor Swimming Pool. Section 406.1 of the Appendix Chapter 4, Division I subparagraph 1 of the Uniform Building Code is amended to read as follows: "1. The top of the barrier shall be at least 60 inches above grade measured on the side of the barrier which faces away from the swimming pool. The maximum vertical clearance between grade and the bottom of the barrier shall be 2 inches measured on the side of the barrier which faces away from the swimming pool. This may be increased to 4.inches when the grade is of a solid surface such as concrete decking. 20 All required fencing shall be constructed so as to limit the climbability of the fencing. Any decorative design work on the side away from the swimming pool, such as protrusions, indentations or cutouts, which render the barrier easily climbable, is prohibited." DD. Chanter 98, Unoccupied Buildings and Structures, and Chapter 99, Building and Property Rehabilitation added. Chapters 98 and 99 of the Los Angeles County Building Code, most current edition, are hereby adopted in their entirety. k�egbwde.,b 21 SECTION 3. If any section, subsection, sentence, clause, phrase or word of this ordinance is for any reason held to be invalid by a court of competent jurisdiction, such a decision shall not affect the validity of the remaining portions of this ordinance. The City Council hereby declares that it would have passed and adopted this ordinance and all of the provisions thereof, irrespective of the fact that any one or more of said provisions may be declared invalid. SECTION 4. The City Clerk shall certify to the passage of this ordinance. PASSED AND APPROVED this day of 19 MAYOR ATTEST: CITY CLERK STATE OF CALIFORNIA ) COUNTY OF LOS ANGELES ) § CITY OF SANTA CLARITA ) I, Sharon L. Dawson, City Clerk of the City of Santa Clarita, do hereby certify that the foregoing Ordinance No. was regularly introduced and placed upon its first reading at a regular meeting of the City Council on the day of 19 That thereafter, said Ordinance was duly adopted and passed at a regular meeting of the City Council on the day of 19 by the following vote, to wit: AYES: COUNCILMEMBERS ABSENT: COUNCILMEMBERS CITY CLERK mmalle9�eod9jb.ce