Agenda Item: 9
CITY OF SANTA CLARITA
AGENDA REPORT
City Manager Approval:
Item to be presented by:
November 26, 2013
Damon Letz
SECOND READING AND ADOPTION OF AN ORDINANCE TO
ADOPT THE 2013 CALIFORNIA BUILDING STANDARDS
CODE WITH LOCAL AMENDMENTS, AMENDING TITLES 18,
19, 20, 21, 22, 24, AND 25 OF THE SANTA CLARITA
MUNICIPAL CODE
Public Works
RECOMMENDED ACTION
City Council:
Conduct a public hearing for the adoption of the 2013 California Building Standards Code
with local amendments.
2. Adopt an ordinance entitled "AN ORDINANCE OF THE CITY COUNCIL OF THE CITY
OF SANTA CLARITA, CALIFORNIA, REPEALING AND REPLACING TITLES 18
THROUGH 22, AND TITLES 24 AND 25 OF THE SANTA CLARITA MUNICIPAL
CODE AND ADOPTING BY REFERENCE THE 2013 CALIFORNIA
ADMINISTRATIVE, BUILDING, RESIDENTIAL, ELECTRICAL, MECHANICAL,
PLUMBING, ENERGY, EXISTING BUILDING, HISTORICAL BUILDING, FIRE,
GREEN BUILDING STANDARDS, AND REFERENCED STANDARDS CODES WITH
CERTAIN APPENDICES AND LOCAL AMENDMENTS."
BACKGROUND
At the November 12, 2013, City Council meeting an ordinance was introduced and passed to
second reading to adopt the 2013 California Building Standards Code (building code) along with
local amendments. At the meeting, a public hearing was set, in accordance with Government
Code Section 50022.3, to consider adoption of the ordinance. Public notice was duly given for
the public hearing in compliance with the State of California (State) law, and a copy of the
proposed codes and local amendments was made available for public view in the City Clerk's
office.
Adoption of this ordinance will ensure the City of Santa Clarita (City) continues to enforce the
latest adopted building codes along with updated local amendments, thus providing for the safety
and welfare of all citizens through the implementation of the latest technology, materials,
engineering, construction, and sustainability methods, as regulated by the latest adopted building
codes.
The ordinance establishes an effective date of January 1, 2014, to commence enforcement of
building codes and local amendments. This date conforms to the effective date established by the
State for mandatory enforcement of the new codes.
ALTERNATIVE ACTIONS
Should City Council elect not to adopt the proposed State codes and local amendments, the City
would still be required to enforce the new State codes as set forth in Health & Safety Code 17922
and 17958 et al. Additionally, the updated local amendments, if not adopted, would not be
enforceable. Failure to adopt the ordinance could also result in a downgrading of the City's
Insurance Services Office rating, thereby negatively affecting the insurance rates for new
construction.
FISCAL IMPACT
This ordinance does not increase permit -related fees nor does it modify any fees charged to the
public for Building & Safety provided services.
ATTACHMENTS
Ordinance -
Title 18 City Building Code - adoption and local amendments
Title 19 City Electrical Code - adoption and local amendments
Title 20 City Plumbing Code - adoption and local amendments
Title 21 City Mechanical Code - adoption and local amendments
Title 22 City Fire Code - adoption
Title 24 City Energy Conservation Code - adoption
Title 25 City Green Building Standards Code - adoption
Public Notice
ORDINANCE NO. 13 -
AN ORDINANCE OF THE CITY COUNCIL OF THE CITY OF
SANTA CLARITA, CALIFORNIA, REPEALING AND REPLACING TITLES 18 THROUGH
22, AND TITLES 24 AND 25 OF THE SANTA CLARITA MUNICIPAL CODE AND
ADOPTING BY REFERENCE THE 2013 CALIFORNIA ADMINISTRATIVE, BUILDING,
RESIDENTIAL, ELECTRICAL, MECHANICAL, PLUMBING, ENERGY, EXISTING
BUILDING, HISTORICAL BUILDING, FIRE, GREEN BUILDING STANDARDS, AND
REFERENCED STANDARDS CODES WITH CERTAIN APPENDICES AND LOCAL
AMENDMENTS
WHEREAS, the State of California (State) requires by its Government Code that
local jurisdictions adopt the latest State Building Standards Code; and
WHEREAS, the State has adopted and published the 2013 California Administrative,
Building, Residential, Electrical, Mechanical, Plumbing, Energy, Existing Building, Historical
Building, Fire, Green Building Standards, and Referenced Standards Codes comprising Title 24
of the California Code of Regulations, Parts 1 through 12, with each becoming effective on
January 1, 2014; and
WHEREAS, the State allows local jurisdictions to amend said codes in accordance
with Health and Safety Code Section 18941.5 (b) where necessary to reasonably address adverse
local conditions related to climate, geology, and/or topography; and
WHEREAS, the City Council finds the local topography consists of natural hillsides,
canyons, and rugged terrain that can contribute to accelerated spread of wildfires, and the local
climate consists of hot, dry, and wind conditions during the summer and fall creating severe fire
hazard that warrants enhanced construction provisions for fire safety; and
WHEREAS, the City Council also finds the local geology consists of an active Class
B earthquake fault, geologic formations, and areas subject to liquefaction presenting a significant
earthquake risk that warrants enhanced design and construction provisions for structural safety;
and
WHEREAS, the City Council also finds the need to modify and/or add certain
administrative provisions to effectively enforce the regulations contained in the 2013 California
Building Standards Code; and
WHEREAS, this Ordinance repeals the current City Building, Electrical, Plumbing,
Mechanical, Fire, Energy Conservation, and Green Building Standards Codes and amendments
thereto and adopts the new 2013 California Administrative, Building, Residential, Electrical,
Mechanical, Plumbing, Energy, Existing Building, Historical Building, Fire, Green Building
Standards, and Referenced Standards Codes with local amendments; and
WHEREAS, enforcement of the 2013 California Building Standards Code are
mandated by the State to commence on January 1, 2014.
3
NOW THEREFORE, THE CITY COUNCIL OF THE CITY OF SANTA CLARITA,
CALIFORNIA, DOES HEREBY ORDAIN AS FOLLOWS:
SECTION 1. That current Titles 18 through 22, Title 24, and Title 25 of the Santa
Clarita Municipal Code are hereby repealed.
SECTION 2. Titles 18 through 22, Title 24, and Title 25 of the Santa Clarita
Municipal Code are replaced with the revised editions consisting of the adoption of the 2013
State codes with local amendments, outlined as follows and to read as attached:
TITLE 18, CITY BUILDING CODE
TITLE 19, CITY ELECTRICAL CODE
TITLE 20, CITY PLUMBING CODE
TITLE 21, CITY MECHANICAL CODE
TITLE 22, CITY FIRE CODE
TITLE 24, CITY ENERGY CONSERVATION CODE
TITLE 25, CITY GREEN BUILDING STANDARDS CODE
SECTION 3. This Ordinance shall become effective and in full force on
January 1, 2014.
SECTION 4. The City Clerk shall certify to the passage of this Ordinance and shall
cause the same to be published as required by law.
PASSED, APPROVED, AND ADOPTED this day of 2013.
MAYOR
ATTEST:
INTERIM CITY CLERK
"Al
STATE OF CALIFORNIA )
COUNTY OF LOS ANGELES ) ss.
CITY OF SANTA CLARITA )
I, Arming Chaparyan, Interim City Clerk of the City of Santa Clarita, do hereby certify
that the foregoing Ordinance 13- was regularly introduced and placed upon its first reading at
a regular meeting of the City Council on the day of 2013. That thereafter, said
Ordinance was duly passed and adopted at a regular meeting of the City Council on the day
of 2013, by the following vote, to wit:
AYES: COUNCILMEMBERS:
NOES: COUNCILMEMBERS:
ABSENT: COUNCILMEMBERS:
AND I FURTHER CERTIFY that the foregoing is the original of Ordinance and
was published in The Signal newspaper in accordance with State Law (G.C. 40806).
INTERIM CITY CLERK
til
Title 18
CITY BUILDING CODE
Chapters:
18.01 Adoption of the City Building Code
18.02 Amendments to CBC Chapter 1 Division II; Scope and Administration
18.03 Amendments to CBC Chapter 15; Roof Assemblies and Rooftop Structures
18.04 Amendments to CBC Chapter 16; Structural Design
18.05 Amendments to CBC Chapter 17; Structural Tests and Special Inspections
18.06 Amendments to CBC Chapter 18; Soils and Foundations
18.07 Amendments to CBC Chapter 19; Concrete
18.08 Amendments to CBC Chapter 23; Wood
18.09 Amendments to CBC Chapter 25; Gypsum Board and Plaster
18.10 Amendments to CBC Appendix G; Flood Resistant Construction
18.11 Amendments to CRC Chapter 1; Division II; Administration
18.12 Amendments to CRC Chapter 3; Building Planning
18.13 Amendments to CRC Chapter 4; Foundations
18.14 Amendments to CRC Chapter 5; Floors
18.15 Amendments to CRC Chapter 6; Wall Construction
18.16 Amendments to CRC Chapter 8; Roof -Ceiling Construction
18.17 Amendments to CRC Chapter 10; Chimneys and Fireplaces
I
Chapter 18.01
ADOPTION OF THE CITY BUILDING CODE
Sections:
18.01.010 Adoption of the City Building Code
18.01.010 Adoption of the City Building Code
There is hereby adopted by reference that certain code known and designated as the California Code of
Regulations, Title 24, Parts 1, 2, 2.5, 6, 8,10, and 12 as published by the California Building Standards
Commission as further described and including the following:
2013 California Administrative Code (California Code of Regulations Title 24, Part 1)
2013 California Building Code (California Code of Regulations Title 24, Part 2) based on the 2012
International Building Code® as prepared by the Intemational Code Council, and as amended by the
State of California
2013 California Residential Code (California Code of Regulations Title 24, Part 2.5) based on the
2012 International Residential Code® as prepared by the International Code Council, and as amended
by the State of California
2013 California Historical Building Code (California Code of Regulations Title 24, Part 8)
2013 California Existing Building Code (California Code of Regulations Title 24, Part 10) based on
the 2012 International Existing Building Cale® as prepared by the International Code Council, and as
amended by the State of California
2013 California Referenced Standards Code (California Code of Regulations Title 24, Part 12)
Such code shall include those sections requiring enforcement by the local building department, and as further
amended by the City of Santa Clarita with provisions intended to address local climatic, geologic, and
topographic conditions, as permitted by State law. Adoption of said code shall include the adoption of
Appendix C Group U -Agricultural Buildings, Appendix G Flood Resistant Construction, and Appendix J
Grading, contained in the 2013 California Building Code and Appendix H Patio Covers, contained in the 2013
California Residential Code.
Such Code shall be and become the City of Santa Clarita Building Code, regulating the erection, construction,
alteration, repair, relocation, demolition, occupancy, use, height, area, and maintenance of all buildings and
structures, and certain equipment therein specifically regulated. The provisions of said code shall provide for
the issuance of permits and certificates of occupancy, and collection of fees thereof, and providing penalties
for violation of such Code.
The City of Santa Clarita Building Code shall become effective for all new building permit applications
received by the City on or after January 1, 2014.
At least one copy of the City of Santa Clarita Building Code shall be maintained and kept available for
reference and examination by the public at the City's Permit Center public counter.
Chapter 18.02
AMENDMENTS TO CHAPTER 1 DIVISION II; SCOPE AND ADMINISTRATION,
OF THE CALIFORNIA BUILDING CODE
Sections:
18.02.005
Chapter 1 Division II is Amended
18.02.010
Subsection 101.1 is Amended
18.02.020
Subsection 103.1 is Amended
18.02.030
Subsection 104.10.1 is Amended
18.02.040
Subsection 105.2 is Amended
18.02.050
Subsection 105.2.2 is Amended
18.02.060
Subsection 105.3.2 is Amended
18.02.070
Subsection 105.5 is Amended
18.02.080
Subsections 105.5.1 and 105.5.2 are Added
18.02.090
Subsection 105.8 is Amended
18.02.100
Subsection 107.1 is Amended
18.02.110
Subsection 107.2.1 is Amended
18.02.120
Subsection 109.2 is Amended
18.02.130
Subsection 109.2.1 is Added
18.02.140
Subsection 109.4 is Amended
18.02.150
Subsection 109.6 is Amended
18.02.160
Subsection 110.3.5 is Amended
18.02.170
Subsection 110.3.11 is Added
18.02.180
Subsection 110.7 is Amended
18.02.190
Subsection 110.8 is Added
18.02.200
Subsection 110.9 is Added
18.02.210
Subsection 113.3 is Amended
18.02.220
Subsection 113.4 is Added
18.02.230
Subsections 114.2.1 and 114.2.2 are Added
18.02.240
Subsection 114.4 is Amended
18.02.250
Section 117 is Added
18.02.260
Section 118 is Added
18.02.005 Chapter 1 Division II is Amended.
The following sections of Chapter 1 Division H of the California Building Code, as adopted by Chapter
18.01 hereof, are added, deleted or amended as follows:
18.02.010 Subsection 101.1 is Amended
Subsection 101.1 is amended to read as follows:
101.1 Title. These regulations, including all duly adopted local amendments, shall be known as the
Santa Clarita Building Code and shall be used in conjunction with the provisions of Title 24, California
Code of Regulations, mandated by the State of California to be enforced by the local Building
Department, and shall hereinafter be referred to as "this code."
18.02.020 Subsection 103.1 is Amended
Subsection 103.1 is amended to read as follows:
103.1 Creation of enforcement agency. There is established within the City of Santa Clarita, a
division in the Public Works Department to be known as the `Building & Safety Division' under the
administrative and operational control of the City Building Official hereafter referred to as the Building
Official.
no
18.02.030 Subsection 104.10.1 is Amended
Subsection 104.10.1 is amended to read as follows:
104.10.1 Flood hazard areas. The Building Official shall not grant modifications to any provision
required in flood hazard areas as established by Section 1612.3 of this code unless a determination has
been made in accordance with the Floodplain Management portion of the Santa Clarita Municipal
Code, Title 10, Chapter 10.06. Refer to Appendix G of this code for Flood -resistant construction
requirements
18.02.040 Subsection 105.2 is Amended
Subsection 105.2 is amended to read as follows:
105.2 Work Exempted from Permit. Exemptions from permit requirements of this code shall not be
deemed to grant authorization for any work to be done in any manner in violation of the provisions of
this code or any other laws or ordinances of the City of Santa Clarita including such requirements as
may be established by any City department or division or the requirements of any other governing
agency. Unless otherwise exempted, separate plumbing, electrical, and mechanical permits will be
required for any such items exempted herein.
Permits shall not be required for the following:
Building:
1. One-story detached light -framed accessory structures used as tool and storage sheds, playhouses,
trellis structures, gazebos, arbors, greenhouses and similar uses where the gross floor area does
not exceed 120 square feet as measured to the outside walls or support posts and the structure
complies with all of the following conditions:
a. The floor is not more than 30 inches above the adjoining grade,
b. The overall height is not more than 14 feet as measured from adjacent grade,
c. The structure is not constructed on a slope steeper than 3:1,
d. The structure is not within a flood hazard or floodplain,
e. The structure has no permanent heating or air-conditioning,
f. The location of the structure is approved by the City's Planning Division.
Note: Storage or tool sheds over 120 square feet but not exceeding 250 square feet in area that
meet the above conditions may be constructed under a 'foundation only' permit. Such permit may
include the installation of one 20 Amp branch circuit, (1) light fixture and one (1) 110/115 V.
GFCI outlet.
2. Where allowed by the City's Planning Division, chain link or wire fences not over 12 feet in
height, wood, vinyl, or open wrought iron fences not over 6 feet in height, and block walls or
pilasters not over 42 inches in height where not constructed within a flood hazard or floodplain.
3. Sidewalks and driveways which are not more than 30 inches above adjacent grade and not over
any basement or story below, and are not part of an accessible route as required per Chapter I IA
or I IB of this code.
4. Decks or platforms accessory to a Group R-3 or U occupancy that are not more than 30 inches
above adjacent grade or constructed over a slope or in a flood hazard or floodplain.
5. Exterior hardscape features such as patios, seating walls, walkways, stepped walks or stairs
integrated in a slope, koi ponds, fountains or similar water features not over 18 inches in depth,
raised planters and similar hardscape features that are accessory to a Group R-3 or U occupancy.
6. Canopies, awnings, or open trellises that do no extend more than 36 inches from the exterior wall
of a building or, if attached to a Group R, Division 3, or Group U occupancy, do not extend more
than 54 inches and are not within 3 feet of the property line.
7. Retaining walls that are not over 4 feet in height measured from the bottom of the footing to the
top of the wall, or where supporting a slope or surcharge, not more than 30 inches in height
measured from bottom of footing to the top of the wall. For 'dry stacked' interlocking retaining
wall systems such as 'keystone walls' the maximum exempt height is 36 inches above the lowest
adjacent grade or 18 inches where supporting a slope or surcharge. This exemption does not apply
1541
to retaining walls constructed on a slope steeper than 3:1, located in a floodplain, or impounding
Class I, II or IIIA liquids.
8. Fixed or moveable cases, racks, shelving, and partitions not exceeding 6 feet in height. The
installation of such elements shall not reduce aisle widths, clearances or means of egress to less
than that required by this Code.
9. The installation of decorative moldings, trim, window treatments, wall coverings, painting,
papering, tiling, carpeting, hardwood or tile flooring, counters or countertops, tub or shower
surrounds and similar interior finish work. Notwithstanding, all such materials and work shall
comply with applicable provisions of Chapter 8 of this Code for allowable materials,
combustibility and fire performance.
10. Garage and closet organizers, cabinets, or shelving not exceeding 8 feet in height within a Group
R-3 or U occupancy.
It. Drywall within Group U occupancies not required to be part of a fire rated assembly.
12. The installation of replacement window units where installed within existing frames and where no
stucco or siding is removed, provided the following conditions are met:
a. The net opening area of the existing window(s) is not reduced to less than that required
by Sections 1203, 1205, and R303 of this code for light and ventilation
b. Any required egress (emergency escape) window, is replaced with an egress (emergency
escape) window complying with Section 1029.1 or R310
c. The provisions of Section 2406 herein for safety glazing are met.
13. Satellite dishes not exceeding 30 inches in diameter where attached to a structure, or 36 inches in
diameter where ground mounted and not exceeding 15 feet in height.
14. Radio or television antennae towers where ground mounted and not exceeding 30 feet in height.
15. Light standards which do not exceed 20 feet in height (electrical permits are required).
16. Flagpoles not exceeding 20 feet in height where not attached to or erected on any building or
structure.
17. Prefabricated swimming pools or spas accessory to a Group R-3 occupancy provided that:
a. The capacity does not exceed 5,000 gallons
b. The pool or spa is not constructed on a slope greater than 3:1
c. The lowest point of the bottom of the pool or spa is not more than 24 inches below
adjacent grade
d. The pool or spa is provided with a safety barrier as required in the California Health &
Safety Code
An electrical permit is required for any permanently connected pumps or motors.
18. Structures or equipment accessory to a Group R occupancy which are intended solely for play or
amusement, and which are clearly identifiable as such. These structures may include, but are not
limited to: swings, slides, climbing structures and similar playground equipment, skateboard or
bike ramps, pool slides whether built-in or free standing, basketball standards, tennis or sports
courts (not including fencing or lighting), and similar structures. Notwithstanding, such structures
must comply with all applicable zoning standards for use and location. Where a permanently
constructed pool slide or other landscape feature also serves as part of a retaining wall, such
portions of the construction that act as a retaining wall require a permit unless specifically
exempted here in. An electrical permit is required for any permanently connected lighting or other
electrical equipment.
19. Tree houses provided that:
a. The floor area does not exceed 64 square feet;
b. The ceiling height does not exceed 6 feet;
c. It is not constructed in an oak tree.
20. Temporary sheds, construction trailers, and other structures incidental to work authorized by a
valid grading or building permit. Electrical and plumbing permits are required when there are any
such connections associated with the temporary shed or construction trailer. Any such structure
shall be removed upon completion of the work covered by the permit or expiration of the permit.
21. Tents, inflatable structures, and similar canopy structures, where used in conjunction with a
special event, that are open on at least three sides and do not exceed 500 square feet in projected
area, or where enclosed on two or more sides, that do not exceed 300 square feet in enclosed area.
Notwithstanding, all such structures shall be adequately anchored to resist local wind forces.
to
22. Temporary stages or platforms that do not exceed 30 inches in height that are used in conjunction
with a special event.
23. Shade cloth structures constructed solely for nursery or agricultural purposes, not including
service systems within such structures.
24. Temporary motion picture, television, and theater stage sets and scenery.
25. Gantry cranes and similar equipment.
26. Prefabricated water tanks supported directly on grade where the capacity does not exceed 5,000
gallons and the ratio of height to the diameter or width does not exceed one and one-half to one
(1'h:1).
27. The following work when conducted in association with an operating oil field:
a. Oil derricks;
b. Installation and relocation of process vessels and tanks;
c. Construction, installation and relocation of process piping and pipe supports;
d. Construction, installation and relocation of ladders, stairs, and catwalks;
e. Installation of foundations for process vessels, pipe supports, generators, tanks, pumps,
and uninhabited buildings located more than 20 feet from any property line;
f. Construction, installation, and relocation of uninhabited buildings;
g. Road maintenance;
h. Grading of new and existing well pads, provided the grading does not affect an adjoining
property;
i. Grading and construction for erosion control, provided it does not effect an adjoining
property;
j. Debris basin maintenance;
(Note: The waiver of a building permit shall not be deemed as a waiver from the oil field
operator from obtaining the required clearances from other public agencies.)
Electrical:
Note: refer to the 2013 California Electrical Code with local amendments for additional exemptions
1. low -voltage wiring for security systems, telephone or other communication systems, door bells,
intercom or sound systems, television cable, and similar installations within a Group R-3 or U
occupancy.
2. Electrical equipment used for commercial radio and television transmitting stations, excluding
any equipment or wiring for the power supply to any such station.
Mechanical
Note: refer to the 2013 California Mechanical Code with local amendments for additional exemptions
1. Portable equipment including heating appliances, ventilation equipment, air-conditioning or
evaporative cooling units.
2. Self-contained refrigeration systems containing 10 pounds or less of refrigerant and actuated by
motors of 1 horsepower or less.
15.02.050 Subsection 105.2.2 is Amended
Subsection 105.2.2 is amended to read as follows:
105.2.2 Repairs and Maintenance. Application or notice to the Building Official is not required for
ordinary maintenance or repairs to structures. In no case shall the repair or maintenance work create
an unsafe condition or violate any provision of State or codes. Such repairs shall not include the
cutting away of any wall, partition or portion thereof, the removal or cutting of any structural beam or
load-bearing support, or the removal or change of any required means of egress, or rearrangement of
parts of a structure affecting the egress requirements.
Permits shall not be required for the following repair or maintenance work:
1. General building maintenance.
2. Painting, papering, carpeting and similar work.
3. Repair of minor portions of a building or structure damaged by dry -rot, termites, or deterioration
provided the elements being replaced do not reduce the integrity of the building or structure.
4. Repairs to a roof on a building or structure not exceeding 10 percent of the total roof area or 200
square feet, whichever is less, provided such exempt limits are not exceeded within any one-year
period of time.
5. Drywall repairs not exceeding 200 square feet when not part of a fire rated assembly.
6. Replacement of panes of glass within existing frames provided the provisions of Section 2406 of
this Code for safety glazing are met. Note: refer to exemption 12 under Section 105.2 `Work
Exempted from Permit; Building", herein, for additional requirements that may apply.
7. Replacement of any component part of mechanical or electrical equipment provided it does not
alter approval of such equipment or make such equipment unsafe.
8. Replacement of any faucet, sink, water closet, shower head or similar plumbing fixture with a
fixture of like type. Notwithstanding, the replacement of such fixtures shall comply with
applicable provisions of the California Plumbing Code and California Green Building Standards
Code for water -conserving fixtures.
9. Replacement of any kitchen appliance, non-commercial hood, exhaust or ceiling fan, lighting
fixture, lamp or bulb, or similar item with a fixture, appliance, or other item of like type.
10. The clearing of stoppages or the repairing of leaks in drains, water, soil, waste or vent pipe,
provided, however, that if any concealed trap, drainpipe, water, soil, waste or vent pipe or valve
becomes necessary to remove and replace the same with new material, such work shall be
considered as new work and a permit shall be obtained and inspection made as provided in this
code.
Ordinary repairs shall not include addition to, alteration of, replacement or relocation of any
standpipe, water supply, sewer, drainage, drain leader, gas, soil, waste, vent or similar piping, electric
wiring or mechanical or other work affecting public health or general safety.
18.02.060 Subsection 105.3.2 is Amended
Subsection 105.3.2 is amended to read as follows:
105.3.2 Time limitation of application. An application for which no permit is issued within 180
days following the date of application shall expire by limitation, and plans and other data submitted
for review may thereafter be returned to the applicant or destroyed by the Building Official. The
building official is authorized to extend the time for action by the applicant for a period not to exceed
180 days upon request by the applicant. A second extension not exceeding 180 days may be granted
by the building official under all of the following conditions:
1. The applicant submits a written request for such extension showing justifiable cause;
2. There have been no changes to any of the governing codes under which the plans were
originally submitted since the original date of application;
3. An administrative fee as established must be paid at the time the second extension is granted.
Where there have been changes to governing codes under which the plans were originally submitted,
the Building Official may grant a second extension provided the plans are revised to reflect any such
changes as a condition of the extension. Additional plan review fees will apply in such cases. No
further application extensions will be granted after a second extension.
18.02.070 Subsection 105.5 is amended
Subsection 105.5 is amended to read as follows:
105.5 Expiration. Every permit issued shall become invalid unless the work on the site authorized by
such permit is commenced within 180 days after its issuance as evidenced by a valid inspection of work by the
building department. In such cases where the work authorized on the site by such permit has commenced and
is then suspended or abandoned for a period of 180 days after the time the work is commenced the permit shall
become in -active. The Building Official is authorized to grant one or more extensions of time for periods of
time not to exceed 180 days each, or to re -activate a permit as provided for in subsection 105.5.1 and 105.5.2
18.02.080 Subsections 105.5.1 and 105.5.2 are Added
I2-
Subsections 105.5.1 and 105.5.2 are added to read as follows:
105.5.1 Re -activation of an Expired Permit. The Building Official may approve the reactivation of
a permit that has become invalid (either expired or inactive), upon written request by the permittee,
under the following conditions:
1. The suspension or abandonment of work has not exceeded two years.
2. There have been no changes to any of the governing codes under which the permit was
originally issued since the original date of application.
3. Where there have been changes to the governing codes under which the permit was originally
issued, the Building Official may require any work that has not been installed or completed to
meet the provisions of the most current governing codes as a condition of re -activation.
105.5.2 Fees. In order to renew action on a permit after it has become invalid, the permittee shall pay
a fee as determined by the Building Official not to exceed 50 percent of the original permit fee. Any
permit extensions subsequent to an initial extension require the payment of an administrative fee as
determined.
18.02.090 Subsection 105.8 is Added
Subsection 105.8 is added to read as follows:
105.8 Combined Building Permits. A combination permit may be issued for a single project when it
is determined that the same contractor is licensed so as to perform all of the proposed. work associated
with the project and it is reasonable to combine the permits into a single permit.
The following permits may be combined:
1. A combined building permit may be issued for new one -family or two-family dwellings
including additions or alterations thereto. Such permits will include all building, electrical,
plumbing, heating, ventilating and air-conditioning work but will not include fire sprinkler
installations, sewer connections in the public right-of-way, or grading work requiring a permit
as specified in the Unified Development Code.
2. A combined permit may be issued for multi -family residential or non-residential construction
projects under similar conditions as listed under number one (1) above when prior approval
has been granted by the Building Official.
3. A combined building permit may be issued for a swimming pool and shall include excavation
and finish grading for construction of the pool and related landscaping, construction of the
pool structure, decking, pool equipment enclosure walls, and all such plumbing and electrical
work as required for the pool.
4. A combined permit may be issued for a commercial sign and shall include all structural and
electrical work required to install the sign.
Combined permits shall not be issued for separate work which is entirely unrelated and under separate
trades such as building and electrical.
The combined building permit shall be subject to the requirements of this code, the Electrical Code, the
Plumbing Code, the Mechanical Code, the Energy Code and the Green Building Standards Code. The
fee for the combined building permit shall be as provided for in Section 109 herein including
amendments.
18.02.100 Subsection 107.1 is Amended
Subsection 107.1 is amended to read as follows:
107.1 General. Submittal documents consisting of construction documents, statement of special
inspections, geotechnical report and other data shall be submitted with each permit application.
Submittal documents may be submitted in electronic format as determined by the Building Official.
15
The construction documents shall be prepared by a registered design professional as outlined in the
California Business and Professions Code or as determined by the Building Official. Where special
conditions exist, the Building Official is authorized to require additional construction documents to be
prepared by a registered design professional.
Exception: (no change)
18.02.110 Subsection 107.2.1 is Amended
Subsection 107.2.1 is amended to read as follows:
107.2.1 Information on construction documents. Construction documents shall be dimensioned and
drawn to scale upon suitable material. Labeling, lettering, dimensioning, and numbering shall be of a
size and style to be easily read and shall be in conformance with accepted professional practices and
standards for architectural and engineering documents. Electronic media documents may be
submitted as determined by the Building Official. Construction documents shall be of sufficient
clarity and completeness to indicate the location, nature, use and occupancy, and extent of the work
proposed and show in detail that it will conform to the provisions of this code and relevant laws,
ordinances, rules and regulations, as determined by the Building Official. Submitted plans and
specifications, which are deemed incomplete or incorrect, shall be returned to the architect or
registered engineer or other individual in general responsible charge with a request for compliance
with these regulations before checking is begun or resumed by Building & Safety Division staff.
18.02.120 Subsection 109.2 is Amended
Subsection 109.2 is amended to read as follows:
109.2 Schedule of permit fees. On buildings, structures, alterations, additions, electrical, gas,
mechanical and plumbing systems, or any other work requiring a permit, a fee for each permit shall be
paid as established by the City Council. Where a combined permit is issued, the permit fee shall
include the combined fees for applicable building, electrical, mechanical, plumbing, and sewer work.
18.02.130 Subsection 109.2.1 is Added
Subsection 109.2.1 is added to read as follows:
109.2.1 Plans Examination Fees. When submittal documents are required by Section 107.1 a plans
examination review fee shall be paid at the time of submittal of the construction documents to the
building department. Said fee shall be as established by the City Council. When submittal documents
are incomplete or changed by the applicant so as to require additional plan review or when the project
involves deferred submittal items as defined in Section 107.3.4.2, an additional plans examination fee
shall be charged for such additional time as may be required to review all such additional work.
18.02.140 Subsection 109.4 is Amended
Subsection 109.4 is amended to read as follows:
109.4 Work commencing before permit issuance. Any person who commences any work on a
building, structure, electrical, gas, mechanical, or plumbing system for which a permit is required by
this code before obtaining the necessary permits shall be subject to an investigation fee whether or not
a permit is then or subsequently issued. The investigation fee shall be equal to twice the amount of the
permit fee. Payment of such fee shall not exempt any person from compliance with all other
provisions of this code nor from any other penalty prescribed by law.
18.02.150 Subsection 109.6 is Amended
Subsection 109.6 is amended to read as follows:
14
109.6 Retands. The Building Official may authorize refunding of any fee paid hereunder which was
erroneously paid or collected.
The Building Official may authorize refunding of not more than 80 percent of the permit fee paid,
excluding issuance fees or plan review fees, when no work has been done under a permit issued in
accordance with this code and the applicant has submitted a written request to cancel said permit
along with the original signed permit, inspection record card, and construction placard.
The Building Official may authorize refunding of not more than 80 percent of the plans examination
fee paid, excluding any application fee, when an application for a permit for which a plan review fee
has been paid is withdrawn or canceled prior to commencing any plan review.
The Building Official shall not authorize refunding of any fee paid except on written application filed
by the original applicant or permittee not later than 90 days after the date the permit or application for
a permit has expired.
18.02.160 Subsection 110.3.5 is Amended
Subsection 110.3.5 is amended to delete the exception allowed under this subsection which excludes
the need for an inspection of gypsum board that is not part of a fire -resistance -rated assembly or a shear
assembly.
18.02.170 Subsection 110.3.11 is Added
Subsection 110.3.11 is added to read as follows:
110.3.11 Reinspection. A reinspection fee may be assessed for each inspection or reinspection under
any of the following conditions:
1. When such portion of work for which inspection is called is not complete and ready.
2. When corrections previously called for by the inspector have not been made.
3. When the approved plans are not readily available to the inspector at the time of the requested
inspection.
4. When access to the jobsite is not available at the time the inspection was scheduled.
5. When there is a deviation from the approved plans related to the work to be inspected and such
deviation was not previously reviewed and approved by Building & Safety staff.
In instances where a reinspection fee has been assessed, no additional inspection of the work will be
performed until the required fee has been paid.
18.02.180 Subsection 110.7 is Added
Subsection 110.7 is added to read as follows:
110.7 Construction Placard and Inspection Record Card. Work requiring a building permit shall
not be commenced until the permit holder or the permit holder's agent have posted in a conspicuous
location at the construction site, a construction placard provided by the Building Official at the time of
permit issuance. Said placard shall not be removed until final approval of the work by the building
department. The inspection record card shall also be made available so as to allow the Building
Official or his designated representative to conveniently make the required entries thereon regarding
inspection of the work.
The Inspection Record Card shall serve as temporary approval to occupy and/or use the described
project for up to ten (10) working days following the Final Approval date, when signed with a Final
Approval by the Building Official or his designated representative.
10
15
18.02.190 Subsection 110.8 is Added
Subsection 110.8 is added to read as follows:
110.8 Inspections During Declared Emergencies. The Building Official may authorize the
performance of inspections required under this section to be performed by registered design
professionals or by registered deputy inspectors, for repair work during a declared emergency. The
persons performing the inspections shall submit a report, to the satisfaction of the Building Official,
demonstrating that the work they inspected conformed to the requirements of all applicable codes.
The report will be similar to those required by Section 1704.1.2 of this code.
18.02.200 Subsection 110.9 is Added
Subsection 110.9 is added to read as follows:
110.9 Special Inspector registration. Any person who acts in the capacity of a special inspector as
defined in Section 1704.1 of this code for any project within the City of Santa Clarita requiring special
inspections as outlined in Chapter 17 must be registered with the City of Santa Clarita to act in such
capacity. In order to be registered, a person must pay a registration fee as established by the City
Council and demonstrate to the satisfaction of the Building Official that he or she is qualified to
perform those types of special inspections for which he or she is registered. Upon registration, a
registration card will be issued to the individual by the Building Official.
18.02.210 Subsection 113.3 is Amended
Subsection 113.3 is amended to read as follows:
113.3 Qualifications. The Board of Appeals shall consist of those persons currently serving on the
Planning Commission as appointed by the City Council.
18.02.220 Subsection 113.4 is Added
Subsection 113.4 is added to read as follows:
113.4 Filing of Appeals. All appeals shall be made in writing and shall state specifically the order,
decision, or determination made by the Building Official which is being appealed and wherein the
Building Official erred in making the order, decision, or determination. The appeal shall be
accompanied with a fee as established by the City Council. If, after reviewing the information
submitted, the Building Official determines that the appeal does not merit a change in his or her order,
decision, or determination, then the Building Official shall schedule a hearing by the Board of Appeals
and the appellant shall be notified of the date and time of the hearing.
18.02.230 Subsections 114.2.1 and 114.2.2 are Added
Subsection 114.2.1 and 114.2.2 are added to read as follows:
114.2.1 Recordation of Notice of Violation. The Building Official may record a notice with the
County Recorder's Office that a property, building or structure, or any part thereof, is in violation of
any provision of this code provided the provisions of this section are followed. The provisions of this
section are cumulative with other provisions of this code and any other enforcement actions permitted
by this code. A notice of violation may be placed upon the title of a property when violation of the
building codes have been verified and documented to exist on the site.
The following procedures are established for recordation of Notice of Violation:
a. If (1) the Building Official determines that any property, building or structure, or any part
thereof is in violation of any provision of this code; and if (2) the Building Official gives written
notice as specified below of said violation; and if (3) within 45 days of said notice, the property,
buildings, or structures thereon are not brought into compliance with this code, then the Building
Official may, in his sole discretion, at any time thereafter record with the County Recorder's
11
F4
Office a notice that the property and/or any building or structure located thereon is in violation of
this code.
b. Notice shall be provided in writing in accordance with the following:
1. The notice shall be mailed registered, certified or first-class mail, or may be posted at the
site if the site is occupied;
2. The notice shall be addressed to the owner as indicated on the latest county roll;
3. The notice shall specify what violations are being investigated or have been observed or
verified;
4. The notice shall indicate what mitigation action is required by the property owner and the
time frame in which to commence and complete such mitigation;
5. The notice shall indicate that a notice of violation may be recorded with the County
Recorder's Office by the Building Official should said violation(s) not be mitigated
within 45 days of the date of the notice.
114.2.2 Termination of Notice. When the property owner has demonstrated to the Building Official
that violations of the building code no longer exist, and all fees to cover the cost of the investigation of
the violations have been paid to the City, as established by the City Council, the Building Official
shall terminate the notice of violation.
18.02.240 Subsection 114.4 is Amended
Subsection 114.4 is amended to read as follows:
114A Violation penalties. Any person who violates a provision of this code or fails to comply with
any of the requirements thereof or who erects, constructs, alters, or repairs a building or structure in
violation of the approved construction documents or directive of the Building Official, or of a permit
or certificate issued under the provisions of this code, is guilty of a misdemeanor punishable by a fine
not exceeding $1,000.00 or by imprisonment not exceeding six months, or by both such fine and
imprisonment (see Section 17995 of the State Health and Safety Code). Such person shall be guilty of
a separate offense for each and every day or portion thereof during which any violation of any of the
provisions of this code is committed, continued, or permitted to remain.
Further, violators of this code may be subject to administrative citation and general penalties as
provided for in Title 23 of the Santa Clarita Municipal Code.
18.02.250 Section 117 is Added
Section 117 is added to read as follows:
Section 117 prohibited Uses of Building Sites
117.1 Flood and Debris Hazard Sites. Buildings, other structures or appurtenances (including but
not limited to walls and fences of any height) and fill are not permitted in an area determined by the
City to be subject to flood hazard by reason of inundation, overflow, other special flood and debris
hazards or erosion except as discussed in this section.
117.2 Geologic Hazard Sites. Any site or property determined or suspected to have a geologically
hazardous condition or pose a potential threat to nearby properties shall be subject to the provisions of
this subsection.
117.2.1 No building permit shall be issued when the Building Official finds that property outside
the site of the proposed work could be damaged by activation or acceleration of a geologically
hazardous condition, and such activation or acceleration could be attributed to the proposed work
for which the permit is requested. For the purpose of this subsection, geologically hazardous
condition does not include surface displacement due to earthquake faults.
12
V�
117.2.2 Work requiring a building permit by this code is not permitted in an area determined by
the Building Official to be subject to hazard from landslide, settlement or slippage. These hazards
include those from loose debris, slopewash, and the potential for mudflows from natural slopes or
graded slopes. For the purpose of this subsection, landslide, settlement or slippage does not
include surface displacement due to the earthquake faults.
117.2.3 Subject to the conditions of subsection 117.2.1 permits may be issued in the following
cases:
a. When the applicant has submitted a geological and/or engineering report or reports which
show that the hazard will be eliminated prior to the use of occupancy of the land or
structures by modification of topography, reduction of subsurface water, buttressing, a
combination of these methods, or by other means.
b. When the applicant has submitted a geological and/or engineering report or reports which
contain sufficient data to show that the site appears to be in no danger for the intended
use.
c. When the applicant has submitted a geological report which indicates that the site appears
to be geologically safe for the proposed use but is located in an area subject to a hazard of
a geological nature. However, before a permit is issued, the owner first shall record in
the Department of Registrar -Recorder the findings of such report or reports, together with
an agreement relieving the City and all officers and employees thereof of any liability for
any damage or loss which may result from the issuance of such permit. This agreement
shall provide that it is binding on all successors in interest of the owner and shall continue
in effect until the Building Official records in the Department of Registrar -Recorder a
statement that he finds such hazard no longer exists.
d. When the work involves the alteration or minor repair of existing structures and the cost
of such alteration or repair does not exceed 25 percent of the value of the existing
structure, such value to be based on assumed continuation of the established legal use.
Before a permit is issued, the owner shall record in the office of the Department of
Registrar -Recorder (1) a statement that he is aware that the records of the building
official indicate that the property is subject to a physical hazard of a geological nature
and (2) an agreement relieving the City and all officers and employees thereof of any
ability for any damage or loss which may result from issuance of such a permit. This
agreement shall provide that it is binding on all successors in interest of the owner and
shall continue in effect until the Building Official records in the office of the Department
of Registrar -Recorder a statement that he finds such hazard no longer exists. The repair
work shall consist of restoring the original construction. Provision may be made for
adjustment of the floor in anticipation of future settlement. For the purposes of this
subsection "alteration" does not include an addition or additions.
e. When the work involves an addition or additions to an existing structure but is not a
change in use or occupancy and such work does not increase the area of the structure by
more than 25 percent of the area of the structure. Before a permit is issued, the applicant
shall submit a geological and/or engineering report or reports complying with the
provisions of subsection (f) of this section which report or reports contain a finding that
the proposed increased use of the site will not be geologically unsafe, and the owner shall
record in the office of the Department of Registrar -Recorder (1) the finding of such report
or reports and (2) an agreement relieving the City and all officers and employees thereof
of any liability for any damage or loss which may result from the issuance of such a
permit. This agreement shall provide that it is binding on all successors in interest of the
owner and shall continue in effect until the Building Official records in the office of the
Department of Registrar -Recorder a statement that he finds a hazard no longer exists.
f. When the work involves a one-story, light -frame accessory structure not intended or used
13
for human occupancy and not exceeding four hundred (400) square feet in area nor
greater than 12 feet in height.
When the work involves the repair of single-family residences and accessory buildings
where the cost of such repair exceeds 25 percent of the value of the existing building or
involves the replacement of such structures where the loss to be replaced was due to
causes other than landslide, settlement or slippage. Before a permit is issued the owner
shall:
1) Record in the office of the Department of Registrar -Recorder (1) a statement that he
is the owner and that he is aware that the records of the Building Official indicate
that the property is subject to a physical hazard of a geological nature and (2) an
agreement relieving the City and all officers and employees thereof of any liability
for any damage or loss which may result from issuance of such a permit. This
agreement shall provide that it is binding on all successors in interest of the owner
and shall continue in effect until the Building Official records in the office of the
Department of Registrar -Recorder a statement that he finds such hazard no longer
exists.
2) Submit calculations and plans for the proposed reconstruction prepared by a
registered civil engineer and designed to minimize damage while accommodating the
amount of vertical and horizontal displacements which he determines are probable or
which have occurred since the original structure was built, whichever is the greater.
g. Notwithstanding any other provisions of this subsection, the Building Official may, at his
discretion, deny a permit for any building, structure or grading subject to a hazard of a
geological nature which cannot be mitigated and may endanger the health or safety of the
occupants, adjoining property, or the public.
117.3 Fills Containing Decomposable Material. Permits shall not be issued for buildings or
structures regulated by this code within 1,000 feet of fills containing rubbish or other decomposable
material unless the fill is isolated by approved natural or man-made protective systems or unless
designed according to the recommendation contained in a report prepared by a licensed civil engineer.
Such report shall contain a description of the investigation, study and recommendation to minimize
the possible intrusion, and to prevent the accumulation of explosive concentrations of decomposition
gases within or under enclosed portions of such building or structure. At the time of the final
inspection, the civil engineer shall furnish a signed statement attesting that the building or structure
has been constructed in accordance with his recommendations to decomposition gases required herein.
117.4 Conditional Use. Work required by this section as a condition for the use of the site shall be
performed prior to the connection of the utilities or occupancy of the building.
117.5 Methane Gas Hazard Sites. Permits shall not be issued for buildings or structures regulated
by this code on, adjacent to, or within 200 feet of active, abandoned or idle oil or gas well(s) unless
designed according to recommendations contained in a report prepared by a licensed civil engineer
and approved by the Building Official. As used in this section, "well" shall mean any well as defined
by Section 3008, subdivisions (a) and (b) of the California Public Resources Code.
117.6 Geology and Engineering Reports. The Building Official may require an engineering geology
or geotechnical engineering report, or both, where in his opinion such reports are essential for the
evaluation of the safety of the site. The engineering geology or geotechnical engineering report or
both shall contain a finding regarding the safety of the building site for the proposed structure against
hazard from landslide, settlement, or slippage and a finding regarding the effect that the proposed
building or grading construction will have on the geologic stability of the property in question and
properties immediately adjacent. Any engineering geology report shall be prepared by a certified
engineering geologist licensed by the State of California. Any geotechnical engineering report shall be
prepared by a civil engineer qualified to perform this work, such as a geotechnical engineer
experienced in soil mechanics. When both an engineering geology and geotechnical engineering
report are required for the evaluation of the safety of a building site, the two reports shall be
14
I
coordinated before submission to the Building Official.
117.7 Earthquake Faults.
1. General. The construction of a building or structure near a known active earthquake fault and
regulated by this code shall be permitted as set forth in this section.
2. Scope. The provisions of this section shall apply only to permits for buildings or structures on
individual lots or parcels and are not intended to be supplementary to geologic investigations
required to qualify divisions of land as set forth in the Uniform Development Code of the City of
Santa Clarita.
3. Definition. For the purpose of this section, a "geologist" shall be a registered geologist, licensed
by the California State Board of Registration for Geologists and Geophysicists to practice geology
in California.
4. Known Active Earthquake Faults. For the purpose of this section, known active earthquake
faults are those faults which have had displacement within Holocene time (approximately the last
11,000 years) as defined in the most current issue of Special Publication 42 of the California
Division of Mines and Geology.
5. Earthquake Fault Maps. Special studies zone maps within the City of Santa Clarita prepared
under Sections 2622 and 2623 of the California Resources Code which show traces of earthquake
faults are declared to be, on the date of official issues, a part of this code. Special studies zones
maps revised under the above sections of the California Resources Code shall, on the date of their
official issue, supersede previously issued maps. Copies of each of the above maps shall be
available for examination by the public at the City. The City shall maintain maps available to the
public showing the location of known active earthquake faults. In the absence of additional
information, the location of known active earthquake faults shall be as shown on special studies
zones maps.
6. Construction Limitations. No building or structure shall be constructed over or upon the trace of
a known active earthquake fault in the following cases:
a. When the proposed building is within 50 feet of that line designated as the location of a
known active earthquake fault on the aforementioned maps.
b. When the proposed building is within 50 feet of the most probable ground location of the
trace of a known active earthquake fault shown on the aforementioned maps.
In cases when a geologist has not made such a determination, the City may require the excavation
of a trench, as a subsurface exploration for the purpose of determining the absence of a known
active earthquake fault. Such a trench will be required if a lack of distinguishable fault features in
the vicinity prevents the City from determining by a site examination, review of available aerial
photographs, or by other means that the fault trace does not underlie the proposed building. The
trench shall be approximately perpendicular to the most probable direction of the fault trace, at
least 18 inches wide, and at least five feet in depth measured from natural grade, or to a depth
satisfactory to the City.
The trench must be accessible for mapping and inspection by the City, when requested, and meet
the requirements of Title 8 of the California Code of Regulations, Construction Safety Orders.
The trench need not extend further than the full width of the proposed structure plus five feet
beyond the traversed exterior walls. A known active earthquake fault shall be presumed
nonexistent if an exposure is not found in the walls or floor of the trench. The City may require a
more extensive investigation by a geologist as evidence to the absence of a known active
earthquake fault prior to the issuance of a building permit.
EXCEPTION: The provisions of this subsection do not apply to:
1. One-story, light -frame buildings classified as R-3 and U occupancies and not exceeding 1,000
square feet in area or 12 feet in height.
2. Alterations or repairs to an existing building provided that the aggregate value of such work
within any 12 month period does not exceed 50 percent of the value of the existing building.
15
20
3. Swimming pools, retaining walls, fences and minor work of a similar nature.
Special Studies Zones. Work within the special studies zones established under Sections 2622 and
2623 of the California Public Resources Code shall comply with State laws, policies, criteria, rules and
regulations applicable to such work. Fees established by Chapter 7.5 of Division 2 of the California
Public Resources Code shall be collected and disbursed as required by State law. In addition to the
State regulations, the provisions of this section shall apply when geologic investigations, mapping,
aerial photographs, other acceptable data or Special Studies Zones Maps show the location of a known
active earthquake fault as described in this subsection.
18.02.260 Section 118 is Added
Section 118 is added to read as follows:
Section 118 Fire Hazard Zones ("Very High Fire Hazard Severity Zones")
118.1 General. For the purpose of this Code, Fire Hazard Zones are those areas in the City of Santa
Clarita that have been designated as Very High Fire Hazard Severity Zones (VHFHSZ) by the
Director of the California Department of Forestry and Fire Prevention and as shown on a map titled
"City of Santa Clarita Fire Zone Map" retained on file by the City's Building & Safety division. Such
map is declared to be, on the date of issue, a part of this Code. Should revisions be made to the map at
the recommendation of the Director of the California Department of Forestry and Fire Prevention, the
revised map, at the date of issue, shall supersede the previously issued map. A copy of the most
current Fire Zone Map shall be available for examination by the public at the City Hall.
118.2 Scope. The provisions of this section shall apply to new buildings or structures on individual
lots or parcels that are located in a Fire Hazard Zone as determined from the City of Santa Clarita Fire
Zone Map for which an application for a permit is submitted.
118.3 Construction requirements for buildings or structures in the Fire Hazard Zone
118.3.1 General. Any building or structure hereafter erected, constructed, altered, added onto, or
moved within or into a Fire Hazard Zone shall comply with all applicable provisions of Chapter 7A or
Section R327 of this Code.
118.3.2 Roof covering repair or replacement. Roof covering on an existing building or structure that
is being repaired or replaced shall comply with Section 1505.1.1 of this Code.
118.3.3 Exterior wall covering of existing buildings. Where the exterior wall covering of an existing
building or structure is being repaired or replaced and the cumulative area being repaired or replaced
is greater than 50 percent of the total existing wall area, both the new and existing wall covering shall
comply with the provisions of Section 707A or Section R327.7 of this Code in their entirety. The
provisions of this subsection shall be cumulative over any one-year period.
118.3.4 Exterior windows and doors of existing buildings. Where exterior windows and/or doors of
an existing building are being replaced with new windows and/or doors, and where the number of
windows and/or doors being replaced is greater than 50 percent of the total number of windows and/or
doors on the building, all windows and/or doors on the building shall comply with Section 708A or
Section R327.8 of this Code. The provisions of this subsection shall be cumulative over any one-year
period.
16
ZI
Chapter 18.03
AMENDMENTS TO CHAPTER 15; ROOF ASSEMBLIES AND ROOFTOP
STRUCTURES, OF THE CALIFORNIA BUILDING CODE
Sections:
18.03.005
Chapter 15 is Amended
18.03.010
Table 1505.1 is Amended
18.03.020
Subsection 1505.1.3 is Amended
18.03.030
Subsection 1505.6.1 is Added
18.03.040
Subsection 1507.3.1 is Amended
18.03.050
Subsection 1507.8.1 is Amended
18.03.060
Subsection 1507.9.1 is Amended
18.03.070
Subsection 1510.3.1 is Added
18.03.080
Subsection 1510.4 is Amended
18.03.005 Chapter 15 is Amended.
The following sections of Chapter 15 of the California Building Code, as adopted by Chapter 18.01 hereof, are
added, deleted, or amended as follows:
18.03.010 Table 1505.1 is Amended.
Table 1505.1 is amended as follows:
TABLE 1505.1a
MINIMUM ROOF COVERING CLASSIFICATION
FOR TYPES OF CONSTRUCTION
For SI: 1 foot = 304.8 mm, 1 square foot = 0.0929 mZ
a. Unless otherwise required in accordance with Chapter 7A.
18.03.020 Subsection 1505.1.3 is Amended
Subsection 1505.1.3 is amended to read as follows:
1505.1.3 Roof coverings within all other areas. The entire roof covering of every existing structure
where more than 50 percent of the total roof area is replaced within any one-year period, the entire
roof covering of every new structure, and any roof covering applied in the alteration, repair, or
replacement of the roof of every existing structure, shall be fire -retardant roof covering that is at least
Class B.
18.03.030 Subsection 1505.6.1 is Added
Subsection 1505.6.1 is added to read as follows:
1505.6.1 City of Santa Clarita Fire Hazard Zone. Wood shingles and wood shakes are not
permitted to be used in any area that is within the City of Santa Clarita's Fire Hazard Zone (very high
fire hazard severity zone) as shown on the City's Fire Zone Map.
18.03.040 Subsection 1507.3.1 is Amended
17
22
Subsection 1507.3.1 is amended to read as follows:
1507.3.1 Deck Requirements. Concrete and clay file shall be installed only over solid structural
sheathing. Such sheathing shall have a minimum nominal thickness of 15/32".
18.03.050 Subsection 1507.8.1 is amended
Subsection 1507.8.1 is amended to read as follows:
1507.8.1 Deck requirements. Wood shingles shall be installed only over solid structural sheathing.
Such sheathing shall have a minimum nominal thickness of 15/32".
18.03.060 Subsection 1507.9.1 is amended
Subsection 1507.9.1 is amended to read as follows:
1507.9.1 Deck requirements. Wood shakes shall be installed only over solid structural sheathing.
Such sheathing shall have a minimum nominal thickness of 15/32".
18.03.070 Subsection 1510.3.1 is Added
Subsection 1510.3.1 is added to read as follows:
1510.3.1 Inspections, An inspection shall be required for all reroofing installations upon removal of
all existing layers of roof coverings or, where the existing roof covering is to be recovered, prior to the
installation of the new roofing material. Prior to such inspection, any damaged areas of the roof deck
or structural framing members shall be repaired or replaced with new material.
18.03.080 Subsection 1510.4 is Amended
Subsection 1510.4 is amended to read as follows:
1510.4 Roof recovering. Where the application of a new roof covering is proposed over wood
shingle or shake roofs, the entire existing surface roofing material including all layers of wood shingle
or shake shall first be removed. Where spaced sheathing was originally installed as the supporting
material, new solid sheathing shall be added prior to the installation of the new roofing material.
23
Chapter 18.04
AMENDMENTS TO CHAPTER 16; STRUCTURAL DESIGN, OF THE CALIFORNIA
BUILDING CODE
Sections:
18.04.005
Chapter 16 is Amended
18.04.010
Section 1612.3 is Amended
18.04.020
Section 1613.6 is Added
18.04.030
Section 1613.7 is Added
18.04.040
Section 1613.8 is Added
18.04.050
Section 1613.9 is Added
18.04.060
Section 1613.10 is Added
18.04.070
Section 1613.11 is Added
18.04.080
Section 1613.12 is Added
18.04.005 Chapter 16 is Amended.
The following sections of Chapter 16 of the California Building Code, as adopted by Chapter 18.01 hereof, are
added, deleted, or amended as follows:
18.04.010 Section 1612.3 is Amended
Section 1612.3 is amended to read as follows:
1612.3 Establishment of flood hazard areas. There is a map along with supporting data adopted by the
City of Santa Clarita that designates areas of special flood hazard as identified by the Federal Emergency
Management Agency (FEMA) in an engineering report entitled "The Flood Insurance Study for the City of
Santa Clarita", dated September 29, 1989, as amended or revised with the accompanying Flood Insurance
Rate Map (FIRM) and Flood Boundary and FloWway Map (FBFM) and related supporting data along with
any revisions thereto. The most current amended or revised version of the flood hazard map and supporting
data are hereby adopted by reference and declared to be part of this section.
18.04.020 Section 1613.6 is Added
Section 1613.6 is added to read as follows:
1613.6 ASCE 7,12.12.3. Modify ASCE 7 Equation 12.12-1 of Section 12.12.3 to read as follows:
SM = Cd Sax (Equation 12.2-1)
18.04.030 Section 1613.7 is Added
Section 1613.7 is added to read as follows:
1613.7 ASCE 7,12.2.3.1, Exception 3. Modify ASCE 7 Section 12.2.3.1 Exception 3 to read as follows:
3. Detached one- and two-family dwellings up to two stories in height of light frame construction.
18.04.040 Section 1613.8 is Added
Section 1613.8 is added to read as follows:
1613.8 ASCE 7, Section 12.11.2.2.3. Modify ASCE 7, Section 12.11.2.2.3 to read as follows:
12.11.2.2.3 Wood Diaphragms. In wood diaphragms, the continuous ties shall be in addition to the
diaphragm sheathing. Anchorage shall not be accomplished by use of toe nails or nails subject to
19
�
*
withdrawal nor shall wood ledgers or framing be used in cross -grain bending or cross -grain tension.
The diaphragm sheathing shall not be considered effective as providing ties or struts required by this
section.
Wood diaphragms supporting concrete or masonry walls shall comply with the following:
1. The spacing of continuous ties shall not exceed 40 feet. Added chords of diaphragms may be
used to form sub -diaphragms to transmit the anchorage forces to the main continuous crossties.
2. The maximum diaphragm shear used to determine the depth of the sub -diaphragm shall not
exceed 75% of the allowable diaphragm shear.
19.04.050 Section 1613.9 is Added
Section 1613.9 is added to read as follows:
1613.9 Seismic Design Provisions for Hillside Buildings.
1613.9.1 Purpose. The purpose of this section is to establish minimum regulations for the design and
construction of new buildings and additions to existing buildings when constructing such buildings on
or into slopes steeper than one unit vertical in three units horizontal (33.3%). These regulations
establish minimum standards for seismic force resistance to reduce the risk of injury or loss of life in
the event of earthquakes.
1613.9.2 Scope. The provisions of this section shall apply to the design of the lateral -force -resisting
system for hillside buildings at and below the base level diaphragm. The design of the lateral -force
resisting system above the base level diaphragm shall be in accordance with the provisions for seismic
and wind design as required elsewhere in this division.
Exception: Non -habitable accessory buildings and decks not supporting or supported from the
main building are exempt from these regulations.
1613.9.3 Definitions. For the purposes of this section certain terms are defined as follows:
BASE LEVEL DIAPHRAGM is the floor at, or closest to, the top of the highest level of the
foundation.
DIAPHRAGM ANCHORS are assemblies that connect a diaphragm to the adjacent foundation at
the uphill diaphragm edge.
DOWNHILL DIRECTION is the descending direction of the slope approximately perpendicular to
the slope contours.
FOUNDATION is concrete or masonry which supports a building, including footings, stem walls,
retaining walls, and grade beams.
FOUNDATION EXTENDING IN THE DOWNHILL DIRECTION is a foundation running
downhill and approximately perpendicular to the uphill foundation.
HILLSIDE BUILDING is any building or portion thereof constructed on or into a slope steeper
than one unit vertical in three units horizontal (33.3%). If only a portion of the building is
supported on or into the slope, these regulations apply to the entire building.
PRIIv ARY ANCHORS are diaphragm anchors designed for and providing a direct connection as
described in Sections 1613.9.5 and 1613.9.7.3 between the diaphragm and the uphill foundation.
SECONDARY ANCHORS are diaphragm anchors designed for and providing a redundant
20
25
diaphragm to foundation connection, as described in Sections 1613.9.6 and 1613.9.7.4.
UPHILL DIAPHRAGM EDGE is the edge of the diaphragm adjacent and closest to the highest
ground level at the perimeter of the diaphragm.
UPHILL FOUNDATION is the foundation parallel and closest to the uphill diaphragm edge
1613.9.4 Analysis and Design.
1613.9.4.1 General. Every hillside building within the scope of this section shall be analyzed,
designed, and constructed in accordance with the provisions of this division. When the code
prescribed wind design produces greater effects, the wind design shall govern, but detailing
requirements and limitations prescribed in this and referenced sections shall be followed.
1613.9.4.2 Base Level Diaphragm -Downhill Direction. The following provisions shall apply to
the seismic analysis and design of the connections for the base level diaphragm in the downhill
direction.
1613.9.4.2.1 Base for Lateral Force Design Defined. For seismic forces acting in the downhill
direction, the base of the building shall be the floor at or closest to the top of the highest level of the
foundation.
1613.9.4.2.2 Base Shear. In developing the base shear for seismic design, the response
modification coefficient (R) shall not exceed 5 for bearing wall and building frame systems. The
total base shear shall include the fomes tributary to the base level diaphragm including forces from
the base level diaphragm.
1613.9.5 Base Shear Resistance -Primary Anchors.
1613.9.5.1 General. The base shear in the downhill direction shall be resisted through primary
anchors from diaphragm struts provided in the base level diaphragm to the foundation.
1613.9.5.2 Location of Primary Anchors. A primary anchor and diaphragm strut shall be
provided in line with each foundation extending in the downhill direction. Primary anchors and
diaphragm struts shall also be provided where interior vertical lateral -force -resisting elements
occur above and in contact with the base level diaphragm. The spacing of primary anchors and
diaphragm struts or collectors shall in no case exceed 30 feet (9144 mm).
1613.9.5.3 Design of Primary Anchors and Diaphragm Struts. Primary anchors and diaphragm
struts shall be designed in accordance with the requirements of Section 1613.9.5.
1613.9.5.4 Limitations. The following lateral -force -resisting elements shall not be designed to
resist seismic forces below the base level diaphragm in the downhill direction:
1. Wood structural panel wall sheathing,
2. Cement plaster and lath,
3. Gypsum wallboard, and
4. Tension only braced frames.
Braced frames designed in accordance with the requirements of Section 2205.2.2 may be used
to transfer forces from the primary anchors and diaphragm struts to the foundation provided
lateral forces do not induce flexural stresses in any member of the frame or in the diaphragm
struts. Deflections of frames shall account for the variation in slope of diagonal members when
the frame is not rectangular.
1613.9.6. Base Shear Resistance -Secondary Anchors.
21
Z l�
1613.9.6.1 General. In addition to the primary anchors required by Section 1613.9.5, the base
shear in the downhill direction shall be resisted through secondary anchors in the uphill foundation
connected to diaphragm struts in the base level diaphragm.
Exception: Secondary anchors are not required where foundations extending in the downhill
direction spaced at not more than 30 feet (9144 mm) on center extend up to and are directly
connected to the base level diaphragm for at least 70% of the diaphragm depth.
1613.9.6.2 Secondary Anchor Capacity and Spacing. Secondary anchors at the base level
diaphragm shall be designed for a minimum force equal to the base shear, including forces
tributary to the base level diaphragm, but not less than 600 pounds per lineal foot (ASD) (8.76
kN/m). The secondary anchors shall be uniformly distributed along the uphill diaphragm edge and
shall he spaced a maximum of four feet (1219 mm) on center.
1613.9.6.3 Design. Secondary anchors and diaphragm struts shall be designed in accordance with
Section 1613.9.8.
1613.9.7 Diaphragms Below the Base Level -Downhill Direction. The following provisions shall
apply to the lateral analysis and design of the connections for all diaphragms below the base level
diaphragm in the downhill direction.
1613.9.7.1 Diaphragm Defined. Every floor level below the base level diaphragm shall be
designed as a diaphragm.
1613.9.7.2 Design Force. Each diaphragm below the base level diaphragm shall be designed for all
tributary loads at that level using a minimum seismic force factor not less than the base shear
coefficient.
1613.9.7.3 Design Force Resistance -Primary Anchors. The design force described in Section
1613.9.7.2 shall be resisted through primary anchors from diaphragm struts provided in each
diaphragm to the foundation. Primary anchors shall be provided and designed in accordance with
the requirements and limitations of Section 1613.9.5.
1613.9.7.4 Design Force Resistance -Secondary Anchors.
1613.9.7.4.1 General. In addition to the primary anchors required in Section 1613.9.7.3, the
design force in the downhill direction shall be resisted through secondary anchors in the uphill
foundation connected to diaphragm struts in each diaphragm below the base level.
Exception: Secondary anchors are not required where foundations extending in the
downhill direction, spaced at not more than 30 feet (9144 mm) on center, extend up to and
are directly connected to each diaphragm below the base level for at least 70% of the
diaphragm depth.
1613.9.7.4.2 Secondary Anchor Capacity. Secondary anchors at each diaphragm below the
base level diaphragm shall be designed for a minimum force equal to the design force but not
less than 300 pounds per lineal foot (ASD) (4.38 kN/m). The secondary anchors shall be
uniformly distributed along the uphill diaphragm edge and shall be spaced a maximum of four
feet (1219 mm) on center.
1613.9.7.4.3 Design. Secondary anchors and diaphragm struts shall be designed in accordance
with Section 1613.9.8.
1613.9.5 Primary and Secondary Anchorage and Diaphragm Strut Design. Primary and secondary
anchors and diaphragm struts shall be designed in accordance with the following provisions:
1. Fasteners. All bolted fasteners used to develop connections to wood members shall be provided
22
21
with square plate washers at all bolt heads and nuts. Washers shall be minimum 0.229 inch by 3
inches by 3 inches (5.82 mm by 76 mm by 76 mm) in size. Nuts shall be tightened to finger tight
plus one half (1/2) wrench turn prior to covering the framing.
2. Fastening. The diaphragm to foundation anchorage shall not be accomplished by the use of toe -
nailing, nails subject to withdrawal, or wood in cross -grain bending or cross -grain tension.
3. Size of Wood Members. Wood diaphragm struts collectors, and other wood members connected
to primary anchors shall not be less than three-inch (76 mm) nominal width. The effects of
eccentricity on wood members shall be evaluated as required per Item 9.
4. Design. Primary and secondary anchorage, including diaphragm struts, splices, and collectors
shall be designed for 125% of the tributary force.
5. Allowable Stress Increase. The one-third allowable stress increase permitted under Section
1605.3.2 shall not be taken when the working (allowable) stress design method is used.
6. Steel Element of Structural Wall Anchorage System. The strength design forces for steel
elements of the structural wall anchorage system, with the exception of anchor bolts and
reinforcing steel, shall be increased by 1.4 times the forces otherwise required.
7. Primary Anchors. The load path for primary anchors and diaphragm struts shall be fully
developed into the diaphragm and into the foundation. The foundation must be shown to be
adequate to resist the concentrated loads from the primary anchors.
8. Secondary Anchors. The load path for secondary anchors and diaphragm struts shall be fully
developed in the diaphragm but need not be developed beyond the connection to the foundation
9. Symmetry. All lateral force foundation anchorage and diaphragm strut connections shall be
symmetrical. Eccentric connections may be permitted when demonstrated by calculation or tests
that all components of force have been provided for in the structural analysis or tests.
10. Wood Ledgers. Wood ledgers shall not be used to resist cross -grain bending or cross -grain
tension.
1613.9.9 Lateral -Force -Resisting Elements Normal to the Downhill Direction.
1613.9.9.1 General. In the direction normal to the downhill direction, lateral -force -resisting
elements shall be designed in accordance with the requirements of this section.
1613.9.9.2 Base Shear. In developing the base shear for seismic design, the response
modification coefficient (R) shall not exceed 5 for bearing wall and building frame systems.
1613.9.9.3 Vertical Distribution of Seismic Forces. For seismic forces acting normal to the
downhill direction the distribution of seismic forces over the height of the building using Section
12.8.3 of ASCE 7 shall be determined using the height measured from the top of the lowest level
of the building foundation.
1613.9.9.4 Drift Limitations. The story drift below the base level diaphragm shall not exceed
0.007 times the story height at strength design force level. The total drift from the base level
diaphragm to the top of the foundation shall not exceed 3/4 inch (19 mm). Where the story height
or the height from the base level diaphragm to the top of the foundation varies because of a
stepped footing or story offset, the height shall be measured from the average height of the top of
the foundation. The story drift shall not be reduced by the effect of horizontal diaphragm stiffness
1613.9.9.5 Distribution of Lateral Forces.
23
1613.9.9.5.1 General. The design lateral force shall be distributed to lateral -force -resisting
elements of varying heights in accordance with the stiffness of each individual element.
1613.9.9.5.2 Wood Structural Panel Sheathed Walls. The stiffness of a stepped wood
structural panel shear wall may be determined by dividing the wall into adjacent rectangular
elements, subject to the same top of wall deflection. Deflections of shear walls may be
estimated by AF&PA SDPWS Section 4.3.2. Sheathing and fastening requirements for the
stiffest section shall be used for the entire wall. Each section of wall shall be anchored for
shear and uplift at each step. The minimum horizontal length of a step shall be 8 feet (2438
mm) and the maximum vertical height of a step shall be 2 feet, 8 inches (813 mm).
1613.9.9.5.3 Reinforced Concrete or Masonry Shear Walls. Reinforced concrete or
masonry shear walls shall have forces distributed in proportion to the rigidity of each section
of the wall.
1613.9.9.6 Limitations. The following lateral force -resisting -elements shall not be designed to
resist lateral forces below the base level diaphragm in the direction normal to the downhill
direction:
1. Cement plaster and lath,
2. Gypsum wallboard, and
3. Tension -only braced frames.
Braced frames designed in accordance with the requirements of Section 2205.2.2 of this Code
may be designed as lateral -force -resisting elements in the direction normal to the downhill
direction, provided lateral forces do not induce flexural stresses in any member of the frame.
Deflections of frames shall account for the variation in slope of diagonal members when the
frame is not rectangular.
1613.9. 10 Specific Design Provisions.
1613.9.10.1 Footings and Grade Beams. All footings and grade beams shall comply with the
following:
1. Grade beams shall extend at least 12 inches (305 mm) below the lowest adjacent grade and
provide a minimum 24 -inch (610 mm) distance horizontally from the bottom outside face of
the grade beam to the face of the descending slope.
2. Continuous footings shall be reinforced with at least two No. 4 reinforcing bars at the top
and two No. 4 reinforcing bars at the bottom.
3. All main footing and grade beam reinforcement steel shall be bent into the intersecting
footing and fully developed around each comer and intersection.
4. All concrete stem walls shall extend from the foundation and reinforced as required for
concrete or masonry walls.
1613.9.10.2 Protection Against Decay and Termites. All wood to earth separations shall
comply with the following:
1. Where a footing or grade beam extends across a descending slope, the stem wall, grade
beam, or footing shall extend up to a minimum 18 inches (457 mm) above the highest
adjacent grade.
Exception: At paved garage and doorway entrances to the building, the stem wall need
only extend to the finished concrete slab, provided the wood framing is protected with a
moisture proof barrier.
24
2q
2. Wood ledgers supporting a vertical load of more than 100 pounds per lineal foot (ASD)
(1.46 kN/m) and located within 48 inches (1219 mm) of adjacent grade are prohibited.
Galvanized steel ledgers and anchor bolts, with or without wood nailers, or treated or decay
resistant sill plates supported on a concrete or masonry seat, may be used.
1613.9.10.3 Sill Plates. All sill plates and anchorage shall comply with the following:
1. All wood framed walls, including nonbearing walls, when resting on a footing, foundation,
or grade beam stem wall, shall be supported on wood sill plates bearing on a level surface.
2. Power -driven fasteners shall not be used to anchor sill plates except at interior non-bearing
walls not designed as shear walls.
1613.9.10.4 Column Base Plate Anchorage. The base of isolated wood posts (not framed into a
stud wall) supporting a vertical load of 4,000 pounds (ASD) (17.8 kN) or more and the base plate
for a steel column shall comply with the following:
1. When the post or column is supported on a pedestal extending above the top of a footing or
grade beam, the pedestal shall be designed and reinforced as required for concrete or masonry
columns. The pedestal shall be reinforced with a minimum of four No. 4 bars extending to the
bottom of the footing or grade beam. The top of exterior pedestals shall be sloped for positive
drainage.
2. The base plate anchor bolts or the embedded portion of the post base, and the vertical
reinforcing bars for the pedestal, shall be confined with two No. 4 or three No. 3 ties within
the top five inches (127 nun) of the concrete or masonry pedestal. The base plate anchor bolts
shall be embedded a minimum of 20 bolt diameters into the concrete or masonry pedestal.
The base plate anchor bolts and post bases shall be galvanized and each anchor bolt shall have
at least two galvanized nuts above the base plate.
1613.9.10.5 Steel Beam to Column Supports. All steel beam to column supports shall be
positively braced in each direction. Steel beams shall have stiffener plates installed on each side
of the beam web at the column. The stiffener plates shall be welded to each beam flange and the
beam web. Each brace connection or structural member shall consist of at least two 5/8 inch (15.9
mm) diameter machine bolts.
18.04.060 Section 1613.10 is Added
Section 1613.10 is added to read as follows:
1613.10 Suspended Ceilings. Minimum design and installation standards for suspended ceilings shall be
determined in accordance with the requirements of Section 2506.2.1 of this Code and this section.
1613.10.1 Scope. This part contains special requirements for suspended ceilings and lighting systems.
Provisions of Section 13.5.6 of ASCE 7-10 shall apply except as modified herein.
1613.10.2 General. The suspended ceilings and lighting systems shall be limited to 6 feet (1828 mm)
below the structural deck unless the lateral bracing is designed by a licensed engineer or architect.
1613.10.3 Sprinkler Heads. All sprinkler heads (drops) except fire -resistance -rated floor/ceiling or
roof/ceiling assemblies, shall be designed to allow for free movement of the sprinkler pipes with oversize
rings, sleeves or adaptors through the ceiling tile. Sprinkler heads and other penetrations shall have a 2 in.
(50mm) oversize ring, sleeve, or adapter through the ceiling tile to allow for free movement of at least 1
in. (25mm) in all horizontal directions. Alternatively, a swing joint that can accommodate 1 in. (25 mm)
of ceiling movement in all horizontal directions is permitted to be provided at the top of the sprinkler head
extension.
25
30
Sprinkler heads penetrating fire -resistance -rated floor/ceiling or roof/ceiling assemblies shall comply with
Section 714 of this Code.
18.04.070 Section 1613.11 is Added
Section 1613.11 is added to read as follows:
1613.11 Power Actuated Fasteners. The provisions of Section 13.4.5 of ASCE 7 shall apply to the design
of power actuated fasteners. Power actuated fasteners shall not be used to anchor sill plates or tracks except
at interior non-bearing walls not designed as shear walls.
18.04.080 Section 1613.12 is Added
Section 1613.12 is added as follows:
1613.12 Light -gage mudsill anchors. Light -gage mudsill anchors which are intended to be bent upon
installation shall not be used to anchor shear walls. Where light -gage anchors are used at exterior walls
not designed as shear walls, they shall be fully protected by the exterior weather barrier assembly or by an
approved corrosion -resistant coating.
26
3I
Chapter 18.05
AMENDMENTS TO CHAPTER 17; STRUCTURAL TESTS AND SPECIAL
INSPECTIONS, OF THE CALIFORNIA BUILDING CODE
Sections:
18.05.005
Chapter 17 is Amended
18.05.010
Section 1705.3 is Amended
18.05.020
Table 1705.3 is Amended
18.05.030
Section 1705.11 is Amended
18.05.005 Chapter 17 is Amended.
The following sections of Chapter 17 of the California Building Code, as adopted by Chapter 18.01 hereof, are
added, deleted, or amended as follows:
18.05.010 Section 1705.3 is Amended
Section 1705.3 is amended to read as follows:
1705.3 Concrete Construction. The special inspections and verifications for concrete construction shall
be as required by this section and Table 1705.3.
Exceptions: Special inspection shall not be required for:
1. Isolated spread concrete footings of buildings three stories or less above grade plane that are
fully supported on earth or rock, where the structural design of the footing is based on a specified
compressive strength, fc, no greater than 2,500 pounds per square inch (psi) (17.2 Wa).
2. Continuous concrete footings supporting walls of buildings three stories or less in height that
are fully supported on earth or rock where:
2.1. The footings support walls of light -frame construction;
2.2. The footings are designed in accordance with Table 1809.7; or
2.3. The structural design of the footing is based on a specified compressive strength, f c, no
greater than 2,500 pounds per square inch (psi) (17.2 Wit), regardless of the compressive
strength specified in the construction documents or used in the footing construction.
3. Nonstructural concrete slabs supported directly on the ground, including prestressed slabs on
grade, where the effective prestress in the concrete is less than 150 psi (1.03 Wa).
4. Concrete patios, driveways and sidewalks, on grade.
27
32
18.05.020 Table 1705.3 is Amended
Table 1705.3, item 4 is amended as follows:
Amend item `4' and add note 'b' to Table 1705.3. Portions of Table 1705.3 not shown remain unchanged.
TABLE 1705.3
RFnTIIRFrI VFRIFICATION AND INSPECTION OF CONCRETE CONSTRUCTION
VERIFICATION AND
INSPECTION
CONTINUOUS
PERIODIC
REFERENCE
STANDARD
IBC
REFERENCE
4. Inspection of anchors post -
installed in hardened
concrete members.
a. Adhesive anchors
installed in horizontally
ACI 318
or upwardly inclined
X
D.9.2.4
orientations to resist
sustained tension loads.
b. Mechanical anchors and
ACI 318
adhesive anchors not
X
D.9.2
defined in 4a.
b. Specific requirements for special inspection shall be included in the research report for the anchor issued by an
approved source in accordance with ACI 355.2 D.9.2 in ACI 318, or other qualification procedures. Where
specific requirements are not provided, special inspection requirements shall be specified by the registered design
professional and shall be approved by the building official prior to the commencement of the work.
18.05.030 Section 1705.11 is Amended
Subsection 1705.11 is amended to read as follows:
1705.11 Special inspections for seismic resistance. Special inspections itemized in Sections 1705.11 .1
through 1705.11.8, unless exempted by the exceptions of Section 1704.2, are required for the following:
1. The seismic force -resisting systems in structures assigned to Seismic Design Category C, D, E or F
in accordance with Sections 1705.11.1 through 1705.11.3, as applicable.
2. Designated seismic systems and associated seismic structural separations in structures assigned to
Seismic Design Category C, D, E or F in accordance with Section 1705.11.4.
3. Architectural, mechanical and electrical components in accordance with Sections 1705.11.5 and
1705.11.6.
4. Storage racks in structures assigned to Seismic Design Category D, E or F in accordance with
Section 1705.11.7.
5. Seismic isolation systems in accordance with Section 1705.11.8.
Exception: Special inspections itemized in Sections 1705.11.1 through 1705.11.8 are not required for
structures designed and constructed in accordance with one of the following:
1. The structure consists of light -frame construction; the design spectral response acceleration at
short periods, SDS, as determined in Section 1613.3.4, does not exceed 0.5; and the building height
of the structure does not exceed 35 feet (10 668 mm)
2. The seismic force -resisting system of the structure consists of reinforced masonry or reinforced
concrete; the design spectral response acceleration at short periods, SDS, as determined in Section
1613.3.4, does not exceed 0.5; and the building height of the structure does not exceed 25 feet
(7620 rum)
W
3�
3. The structure is a detached one- or two-family dwelling not exceeding two stories above grade
plane, is not assigned to Seismic Design Category D, E or F and does not have any of the following
horizontal or vertical irregularities in accordance with Section 12.3 of ASCE 7:
3.1 Torsional or extreme torsional irregularity.
3.2 Nonparallel systems irregularity.
3.3 Stiffness -soft story or stiffness -extreme soft story irregularity.
3.4 Discontinuity in lateral strength -weak story irregularity.
29
3�
Chapter 18.06
AMENDMENTS TO CHAPTER 18; SOILS AND FOUNDATIONS, OF THE
CALIFORNIA BUILDING CODE
Sections:
18.06.005
Chapter 18 is Amended
18.06.010
Subsection 1807.1.4 is Amended
18.06.020
Subsection 1807.1.6 is Amended
18.06.030
Subsection 1808.7.2 is Amended
18.06.040
Section 1809.3 is Amended
18.06.050
Section 1809.4 is Amended
18.06.060
Section 1809.7 and Table 1809.7 are Amended
18.06.070
Section 1809.12 is Amended
18.06.080
Subsection 1810.3.2.4 is Amended
18.06.005 Chapter 18 is Amended.
The following sections of Chapter 18 of the California Building Code, as adopted by Chapter 18.01 hereof, are
added, deleted, or amended as follows:
18.06.010 Subsection 1807.1.4 is Amended
Subsection 1807.1.4 is amended to read as follows:
1807.1.4 Permanent wood foundation systems. Permanent wood foundation systems shall not be
permitted.
18.06.020 Subsection 1807.1.6 is Amended
Subsection 1807.1.6 is amended to read as follows:
1807.1.6 Prescriptive design of concrete and masonry foundation walls. Concrete and masonry
foundation walls that are laterally supported at the top and bottom shall be permitted to be designed and
constructed in accordance with this section. Prescriptive design of foundation walls shall not be used for
structures assigned to Seismic Design Category D, E or F.
18.06.030 Subsection 1808.7.2 is Amended
Subsection 1808.7.2 is amended to read as follows:
1808.7.2 Foundation setback from descending slope surface. Foundations on or adjacent to slope
surfaces shall be founded in firm material with an embedment and set back from the slope surface
sufficient to provide vertical and lateral support for the foundation without detrimental settlement. Except
as provided for in Section 1808.7.5 and Figure 1808.7.1, the following setback is deemed adequate to meet
the criteria. Where the slope is steeper than 1 unit vertical in 1 unit horizontal (100 -percent slope), the
required setback shall be measured from an imaginary plane 45 degrees (0.79 rad) to the horizontal,
projected upward from the toe of the slope. The setback shall be that determined using Figure 1808.7.1 or
5 feet, whichever is larger.
18.06.040 Section 1809.3 is Amended
Subsection 1809.3 is amended to read as follows:
1809.3 Stepped footings. The top surface of footings shall be level. The bottom surface of footings shall be
permitted to have a slope not exceeding one unit vertical in 10 units horizontal (10 -percent slope). Footings
C
35
shall be stepped where it is necessary to change the elevation of the top surface of the footing or where the
surface of the ground slopes more than one unit vertical in 10 units horizontal (10 -percent slope).
For structures assigned to Seismic Design Category D, E or F, the stepping requirement shall also apply to
the top surface of grade beams supporting walls. Footings shall be reinforced with four #4 rebar. Two bars
shall be place at the top and bottom of the footings as shown in Figure 1809.3.
RECONSIEND: a > b
b s 2,01
a
b
STEPPED FOUNDATIONS
Figure 1809.3
18.06.050 Section 1809.4 is Amended
Subsection 1809.4 is amended to read as follows:
1-14IMBAR ROT A BUM
PLATE (PYP.)
- GRADE
1809.4 Depth and width of footings. Where a geotechnical report is not provided and the presence of
expansive soils is unknown, the minimum depth of footings shall be 24 inches (610 mm) for exterior walls
and 18 inches (458 tum) for interior hearing walls. Such footings shall be reinforced with two #4 rebar at
the top and two #4 rebar at the bottom.
Exception: The minimum footing depth for unoccupied group U structures or patio structures
associated with an R-3 occupancy shall be 12 inches (305 mm).
Otherwise, the minimum depth of footings below the undisturbed ground surface shall be 12 inches (305
mm). Where applicable, the requirements of section 1809.5 shall also be satisfied. The minimum width of
footings shall be 12 inches (305 mm).
18.06.060 Section 1809.7 and Table 1809.7 are Amended
Section 1809.7 and Table 1809.7 are amended to read as follows:
1809.7 Prescriptive footings for light -frame construction. Where a specific design is not provided,
concrete or masonry -unit footings supporting walls of light -frame construction shall be permitted to be
designed in accordance with Table 1809.7. Prescriptive footings in Table 1809.7 shall not exceed two
stories above grade plane for structures assigned to Seismic Design Category D, E or F.
31
ala
TABLE 1809.7
PRESCRIPTIVE FOOTINGS SUPPORTING WALLS OF
NUMBER OF FLOORS
SUPPORTED BY THE WIDTH OF FOOTING THICKNESS OF
FOOTING (inches) FOOTING (inches)
Sl: 1 inch = 25.4 mm. I
mm
a. Depth of footings shall be in accordance with Section 1809.4.
b. The ground under the floor shall be permitted to be excavated to the elevation of the top of the
footing.
c. See Section 1908 for additional requirements for concrete footings of structures assigned to Seismic
Design Category C, D, E or F.
d. For thickness of foundation walls, see Section 1807.1.6.
e. Footings shall be permitted to support a roof addition to the stipulated number of floors. Footings
supporting roof only shall be as required for supporting one floor.
18.06.070 Section 1809.12 is Amended
Subsection 1809.12 is amended to read as follows:
1809.12 Timber footings. Timber footings shall not be permitted.
18.06.080 Subsection 1810.3.2.4 is Amended
Subsection 1810.3.2.4 is amended to read as follows:
1810.3.2.4 Timber. Timber deep foundation elements shall not be permitted.
32
3'I
Chapter 18.07
AMENDMENTS TO CHAPTER 19; CONCRETE, OF THE CALIFORNIA BUILDING
CODE
Sections:
18.07.005
Chapter 19 is Amended
18.07.010
Subsection 1905.1.3 is Amended
18.07.020
Subsection 1905.1.8 is Amended
18.07.030
Section 1906.1 is Amended
18.07.005 Chapter 19 is Amended.
The following sections of Chapter 19 of the California Building Code, as adopted by Chapter 18.01 hereof, are
added, deleted, or amended as follows:
18.07.010 Subsection 1905.1.3 is Amended
Subsection 1905.1.3 is amended to read as follows:
1905.1.3 ACI 318, Section 21.4. Modify ACI 318, Section 21.4, by renumbering Section 21.4.3 to
become 21.4.4 and adding new Sections 21.4.3, 21.4.5, 21.4.6 and 21.4.7 to read as follows:
21.4.3 — Connections that are designed to yield shall be capable of maintaining 80 percent of their
design strength at the deformation induced by the design displacement or shall use Type 2 mechanical
splices.
21.4.4 — Elements of the connection that are not designed to yield shall develop at least 1.5 Sy.
21.4.5 — In structures assigned to Seismic Design Category D, E or F, intermediate precast wall panels
and wall piers shall be designed in accordance with Section 21.9 or 21.13.
21.4.6 — Wall piers not designed as part of a moment frame in buildings assigned to Seismic Design
Category C shall have transverse reinforcement designed to resist the shear forces determined from
21.3.3. Spacing of transverse reinforcement shall not exceed 8 inches (203 mm). Transverse
reinforcement shall be extended beyond the pier clear height for at least 12 inches (305 mm).
Exceptions:
1. Wall piers that satisfy 21.13.
2. Wall piers along a wall line within a story where other shear wall segments provide lateral
support to the wall piers and such segments have a total stiffness of at least six times the sum of
the stiffnesses of all the wall piers.
21.4.7 — Wall segments with a horizontal length -to -thickness ratio less than 2.5 shall be designed as
columns.
18.07.020 Subsection 1905.1.8 is Amended
Subsection 1905.1.8 is amended to read as follows:
1905.1.8 ACI 318, Section 22.10. Delete ACI 318, Section 22.10, and replace with the following:
22.10 — Plain concrete in structures assigned to Seismic Design Category C, D, E or F.
22. 10.1 — Structures assigned to Seismic Design Category C, D, E or F shall not have elements of
33
structural plain concrete, except as follows:
(a) Concrete used for fill with a minimum cement content of two (2) sacks of Portland cement
per cubic yard.
(b) Isolated footings of plain concrete supporting pedestals or columns are permitted for
buildings of light frame construction, provided the projection of the footing beyond the face
of the supported member does not exceed the footing thickness and the footing supports a
single roof or floor.
(c) Plain concrete footings supporting walls are permitted provided the footings have at least
two continuous longitudinal reinforcing bars. Bars shall not be smaller than No. 4 and shall
have a total area of not less than 0.002 times the gross cross-sectional area of the footing. A
minimum of one bar shall be provided at the top and bottom of the footing. Continuity of
reinforcement shall be provided at corners and intersections.
In detached one- and two-family dwellings three stories or less in height and constructed with
stud -bearing walls, plain concrete footings with at least two continuous longitudinal
reinforcing bars not smaller than No. 4 are permitted to have a total area of less than 0.002
times the gross cross-sectional area of the footing.
18.07.030 Section 1906.1 is Amended
Section 1906.1 is amended to read as follows:
1906.1 Design. Structural plain concrete walls, footings and pedestals shall be designed for adequate
strength in accordance with ACI 318, Section 22.4 through 22.8.
Exception: For Group R-3 occupancies and buildings or other occupancies less than two stories above
grade plane of light -frame construction, the required footing thickness of ACI 318 is permitted to be
reduced to 6 inches (152 mm), provided that the footing does not extend more than 4 inches (102 mm)
on either side of the supported wall. This exception shall not apply to structural elements designed to
resist seismic lateral forces for structures assigned to Seismic Design Category D, E or F.
34
3°i
Chapter 18.08
AMENDMENTS TO CHAPTER 23; WOOD, OF THE CALIFORNIA BUILDING CODE
Sections:
18.08.005
Chapter 23 is Amended
18.08.010
Subsection 2304.9.1 is Amended
18.08.020
Subsection 2304.9.7 is Amended
18.08.030
Subsection 2304.9.8 is Added
18.08.040
Subsection 2304.11.7 is Amended
18.08.050
Section 2305.4 is Added
18.08.060
Section 2305.5 is Added
18.08.070
Section 2306.2 is Amended
18.08.080
Tables 2306.2(3), 2306.2(4), and 2306.2(5) are Added
18.08.090
Section 2306.3 is Amended
18.08.100
Section 2307.2 is Added
18.08.110
Table 2306.3(4) is Added
18.08.120
Subsection 2308.3.4 is Amended
18.08.130
Subsection 2308.9.3.1 is Amended
18.08.140
Subsection 2308.9.3.2, and Figure 2308.9.3.2 are Amended
18.08.150
Table 2308.12.4 is Amended
18.08.160
Subsection 2308.12.5 is Amended
18.08.005 Chapter 23 is Amended.
The following sections of Chapter 18 of the California Building Code, as adopted by Chapter 18.01 hereof, are
added, deleted, or amended as follows:
18.08.010 Subsection 2304.9.1 is Amended
Subsection 2304.9.1 is amended to read as follows:
2304.9.1 Fastener requirements. Connections for wood members shall be designed in accordance with
the appropriate methodology in Section 2301.2. The number and size of fasteners connecting wood
members shall not be less than that set forth in Table 2304.9.1. Staple fasteners in Table 2304.9.1 shall not
be used to resist or transfer seismic forces in structures assigned to Seismic Design Category D, E or F.
Exception: Staples may be used to resist or transfer seismic forces when the allowable shear values
are substantiated by cyclic testing and approved by the building official.
18.08.020 Subsection 2304.9.7 is Amended
Subsection 2304.9.7 is amended to read as follows:
2304.9.7 Framing requirements. Wood columns and posts shall be framed to provide full end bearing.
Alternatively, column -and -post end connections shall be designed to resist the full compressive loads,
neglecting end -bearing capacity. Column -and -post end connections shall be fastened to resist lateral and
net induced uplift forces. The minimum lateral design force for column and post end connections shall be
2% of the total axial compressive force acting on the column or post, but shall not be less than the force
determined by analysis. The minimum lateral design force shall be assumed to act in any direction.
18.08.030 Subsection 2304.9.8 is Added
Subsection 2304.9.8 is added to read as follows:
35
Irl
2304.9.8 Nails, staples, or spikes in withdrawal. Nails, staples, or spikes shall not be used in withdrawal
to resist the loads prescribed by this code.
Exceptions:
1. Fasteners connecting finish materials weighing 10 psf or less.
2. Fasteners connecting sheathing may be used to resist wind uplift loads.
3. Fasteners connecting roofing or cladding, when specifically approved by this code or by an approved
listing or testing authority.
4. Fasteners connecting mechanical or electrical components weighing 20 lb or less, or in the case of a
distributed system, 5 Ib/ft or less.
18.08.040 Subsection 2304.11.7 is Amended
Subsection 2304.11.7 is amended to read as follows:
2304.11.7 Wood used in retaining walls and cribs. Wood installed in retaining or crib walls shall be
preservative treated in accordance with AWPA U (Commodity Specifications A or F) for soil and fresh
water use. Wood shall not be used in retaining or crib walls for structures assigned to Seismic Design
Category D, E or F.
18.08.050 Section 2305.4 is Added
Section 2305.4 is added to read as follows:
2305.4 Quality of Nails. Mechanically driven nails used in wood structural panel shear walls shall meet
the same dimensions as that required for hand -driven nails, including diameter, minimum length and
minimum head diameter. Clipped head or box nails are not permitted in new construction. The allowable
design value for clipped head nails in existing construction may be taken at no more than the nail -head -
area ratio of that of the same size hand -driven nails.
18.08.060 Section 2305.5 is Added
Section 2305.5 is added to read as follows:
2305.5 Open -front structures. Open front structures utilizing wood -frame rigid diaphragms shall only be
permitted for one-story buildings of occupancy group U.
18.08.070 Section 2306.2 is Amended
Section 2306.2 is amended to read as follows:
2306.2.1 Wood structural panel diaphragms. Wood -frame diaphragms shall be designed and
constructed in accordance with AF&PA SDPWS. Where panels are fastened to framing members with
staples, requirements and limitations of AF&PA SDPWS shall be met and the allowable shear values set
forth in Table 2306.2(1) or 2306.2(2) shall only be permitted for structures assigned to Seismic Design
Category A, B, or C.
Exception: Allowable shear values where panels are fastened to framing members with staples may
be used if such values are substantiated by cyclic testing and approved by the building official.
The allowable shear values in Tables 2306.2(1) and 2306.2(2) are permitted to be increased 40 percent for
wind design.
Wood structural panel diaphragms used to resist seismic forces in structures assigned to Seismic Design
Category D, E or F shall be applied directly to the framing members.
Exception: Wood structural panel diaphragms are permitted to be fastened over solid lumber planking
W.
41
or laminated decking, provided the panel joints and lumber planking or laminated decking joints do
not coincide.
18.08.080 Tables 2306.2(3), 2306.2(4), and 2306.2(5) are Added
Tables 2306.2(3), 2306.2(4), and 2306.2(5) are added as follows:
37
-4�
Table 2306.2(3)
UNBLOCKED Wood Structural Panel DIAPHRAGMS with Framing of Douglas -Fir Larch or Southern Pine
Allowable (ASD) Unit Shear Capacities (pounds per foot)
a. See AF&PA SDPWS for the following: For general construction requirements see 4.2.6. For specific requirements see 4.2.7.1 for wood structural panel
diaphragms. See Appendix A for common nail dimensions.
b. For species and grades of framing other than Douglas -Fir -Larch or Southern Pine, reduced nominal unit shear capacities shall be determined by
multiplying the tabulated nominal unit shear capacity by the Specific Gravity Adjustment Factor = [I -(0.5-G)], where G = Specific Gravity of the framing
lumber from the NDS (Table 11.3.2A). The Specific Gravity Adjustment Factor shall not be greater than 1.
c. See AF&PA SDPWS Table 4.213 for Case definitions.
d. See AF&PA SDPWS Table 4.2C for the apparent shear stiffness values G.-
0
Minimum
Minimum
Minimum
SEISMIC
WIND
6 in. Nail Spacing at diaphragm
6 in. Nail Spacing at diaphragm
Fastener
Nominal
Nominal Width of
Sheathing
Common
Penetration
Panel
Nailed Face at
boundaries and supporting
boundaries and supporting
Grade
Nail Size
in Framing
Thickness
Supported Edges
members
members
and Boundaries
(in.)
(in.)
(in)
Case I
Cases 2,3,4,5,6
Case 1
Cases 2,3,4,5,6
2
240
180
335
252
Sd
1-3/8
3/8
3
265
200
370
280
Structural
2
285
215
400
300
IOil
1-1/2
15/32
3
320
240
447
335
2
165
125
230
175
6d
1-1/4
3/8
3
185
140
260
195
3/8
2
215
160
300
225
3
240
180
335
252
Sheathing and
8d
1-3/8
7/16
2
230
170
322
237
Single -Floor
3
255
190
357
265
2
240
180
335
252
(DOC PSI and
PS2)
IS/32
3
265
200
370
280
2
255
190
357
265
15/32
13
290
215
405
300
]Oil
1-1/2
2
285
215
400
300
19/32
3
320
240
447
335
a. See AF&PA SDPWS for the following: For general construction requirements see 4.2.6. For specific requirements see 4.2.7.1 for wood structural panel
diaphragms. See Appendix A for common nail dimensions.
b. For species and grades of framing other than Douglas -Fir -Larch or Southern Pine, reduced nominal unit shear capacities shall be determined by
multiplying the tabulated nominal unit shear capacity by the Specific Gravity Adjustment Factor = [I -(0.5-G)], where G = Specific Gravity of the framing
lumber from the NDS (Table 11.3.2A). The Specific Gravity Adjustment Factor shall not be greater than 1.
c. See AF&PA SDPWS Table 4.213 for Case definitions.
d. See AF&PA SDPWS Table 4.2C for the apparent shear stiffness values G.-
0
Table 2306.2(4)
BLOCKED Wood Structural Panel DIAPHRAGMS with Framing of Douglas -Fir Larcb or Southern Pine
Allowable (ASD) Unit Shear Capacities (pounds per foot)
a. See AF&PA SDPWS for the following: For general construction requirements see 4.2.6. For specific requirements see 4.2.7.1 for wood structural panel
diaphragms. See Appendix A for common nail dimensions.
b. For species and grades of framing other than Douglas -Fu -Larch or Southern Pine, reduced nominal unit shear capacities shall be determined by multiplying
the tabulated nominal unit shear capacity by the Specific Gravity Adjustment Factor = [1-(0.5-G)], where G = Specific Gravity of the framing lumber from the
NDS (Table 11.3.2A). The Specific Gravity Adjustment Factor shall not be greater than 1.
c. See AF&PA SDPWS Table 4.2B for Case definitions.
d. See AF&PA SDPWS Table 4.2A for the apparent shear stiffness values Ge.
39
SEISMIC
WIND
Nail Spacing (in.) at diaphragm
Nail Spacing (in.) at diaphragm
Minimum
Minimum
Fastener
Minimum
Nominal Width
boundaries (all cases), at continuous
boundaries (all cases), at continuous
Penetration
Nominal
of Nailed Face
panel edges parallel to load (Cases 3 &
panel edges parallel to load (Cases 3 &
Sheathing
Common
in Framing
Panel
at Adjoining
4), and all edges Cases 5 & 6)
an
4), and at all el edges (Cases 1& 6)
Grade
Nail Size
Member or
Thickness
Panel Edges
anel
4
6 2-1/2 2
1
6 4 2-1/2 r 2
Blocking
(in.)
and Boundaries
Nail Spacing (in.) at other panel edges
Nail Spacing (in.) at other panel edges
(in.)
(in.)
(Cases 1, 2, 3, & 4)
(Cases 1, 2, 3, & 4)
6
6
4
3
6
6
4
3
2
270
360
530
600
372
505
742
840
3d
1-3/83/g
3
300
400
600
675
420
560
840
945
SIFUCILrall
2
320
425
640
730
447
595
895
1022
10d
1-1/2
15/32
3
360
480
720
820
505
672
1007
1147
2
185
250
375
420
260
350
525
587
6d
I-1/4
3/8
3
210
280
420
475
295
392
587
665
2
240
320
480
545
335
447
672
762
3/8
3
270
360
540
610
377
505
755
855
Sheathing
2
255
340
505
575
357
475
707
805
and Single-
8d
3/8
7/16
3
285
380
570
645
400
532
797
902
2
270
360
530
600
372
505
742
840
Floor (DOC
PS and PS2)
15/32
3
300
400
600
675
420
560
840
945
2
290
385
575E735
655
405
540
805
917
ISl32
3
325
430
650
455
602
910
1030
lOd
1-1/2
2
320
425
640730
497
595
895
1022
19/32
3
360480
720820
505
1 672
1007
1147
a. See AF&PA SDPWS for the following: For general construction requirements see 4.2.6. For specific requirements see 4.2.7.1 for wood structural panel
diaphragms. See Appendix A for common nail dimensions.
b. For species and grades of framing other than Douglas -Fu -Larch or Southern Pine, reduced nominal unit shear capacities shall be determined by multiplying
the tabulated nominal unit shear capacity by the Specific Gravity Adjustment Factor = [1-(0.5-G)], where G = Specific Gravity of the framing lumber from the
NDS (Table 11.3.2A). The Specific Gravity Adjustment Factor shall not be greater than 1.
c. See AF&PA SDPWS Table 4.2B for Case definitions.
d. See AF&PA SDPWS Table 4.2A for the apparent shear stiffness values Ge.
39
Table 2306.2(5)
Blocked Wood Structural Panel DIAPHRAGMS with Framing of Douglas -Fir Larch or Southern Pine
UTILIZING MULTIPLE ROWS OF FASTENERS (HIGH -LOAD DIAPHRAGMS)
Allowable (ASD) Unit Shear Capacities (pounds per foot)
a. See AF&PA SDPWS for the following: For general construction requirements see 4.2.6. For specific requirements see 4.2.7.1 for wood structural panel
diaphragms. See Figure 4C for nailing diagrams. See Appendix A for common nail dimensions.
b. For species and grades of framing other than Douglas -Fir -Larch or Southern Pine, reduced nominal unit shear capacities shall be determined by multiplying the
tabulated nominal unit shear capacity by the Specific Gravity Adjustment Factor = [ 1-(0.5-G)), where G = Specific Gravity of the framing lumber from the NAS
(Table 11.3.2A). The Specific Gravity Adjustment Factor shall not be greater than 1.
c. See AF&PA SDPWS Table 4.2B for Case definitions.
d. See AF&PA SDPWS Table 42B for the apparent shear stiffness values Ge.
Ell
is
Minimum
SEISMIC
WIND
Nail Spacing (in.) at diaphragm
Nail Spacing (in.) at diaphragm
Minimum
Nominal
Fastener
Minimum
Width of
boundaries (all cases), at continuous
boundaries (all cases), at continuous
Sheathing
Grade
Common
Nail Size
Penetration
m Framing
Member or
Nominal
Panel
Thickness
Nailed Face
at Adjoining
Panel Edges
Lines of
Fasteners
panel edges parallel to load (Cases 3 &
4), and at allanal ed es Cases 5 & 6)
panel edges parallel to load (Cases 3 &
4), and at all panel edges (Cases 5 & 6)
4 2-1/2
4 2-1/2
Nail Spacing (in.) at other panel edges
Nail Spacing (in.) at other panel edges
Blocking
(in.)
and
(in.)
Boundaries
(Cases 1, 2, 3, & 4)
(Cases 1, 2, 3, & 4)
6
4
4
3
6
4
4
3
(in.)
3
2
605
815
875
1150
847
1140
1225
1610
15/32
4
2
700
915
1005
1290
980
1280
1407
1805
4
3
875
1220
1285
1395
1225
1707
1800
1952
3
2
670
880
965
1255
937
1232
1350
1757
Structural
10d
1-1/2
19/32
4
2
780
990
1110
1440
1092
1385
1555
2015
4
3
965
1320
1405
1790
1350
1847
1967
2505
3
2
730
955
1050
1365
1022
1337
1470
1910
23/32
4
2
855
1070
1210
1565
1197
1497
1695
2190
4
3
1050
1430
1525
1800
1470
2002
2135
2520
3
2
525
725
765
1010
735
1015
1070
1415
15/32
4
2
605
815
875
1105
847
1140
1225
1547
Sheathing
4
3
765
1085
1130
1195
1070
1520
1582
1672
3
2
650
860
935
1225
910
1205
1310
1715
and Single-
Floor
10d
1-1/2
19/32
4
2
755
965
1080
1370
1057
1350
1512
1917
(DOC PSI
4
3
935
1290
1365
1485
1310
1805
1910
2080
3
2
710
935
1020
1335
995
1310
1427
1870
and PS2)
23/32
4
2
825
1050
1175
1445
1155
1470
1645
2022
4
1 3
1020
1 1400
1 1480
1565
1 1427
1960
1 2072
2190
a. See AF&PA SDPWS for the following: For general construction requirements see 4.2.6. For specific requirements see 4.2.7.1 for wood structural panel
diaphragms. See Figure 4C for nailing diagrams. See Appendix A for common nail dimensions.
b. For species and grades of framing other than Douglas -Fir -Larch or Southern Pine, reduced nominal unit shear capacities shall be determined by multiplying the
tabulated nominal unit shear capacity by the Specific Gravity Adjustment Factor = [ 1-(0.5-G)), where G = Specific Gravity of the framing lumber from the NAS
(Table 11.3.2A). The Specific Gravity Adjustment Factor shall not be greater than 1.
c. See AF&PA SDPWS Table 4.2B for Case definitions.
d. See AF&PA SDPWS Table 42B for the apparent shear stiffness values Ge.
Ell
is
18.08.090 Section 2306.3 is Amended
Section 2306.3 is amended to read as follows:
2306.3 Wood -frame shear walls. Wood -frame shear walls shall be designed and constructed in accordance with
AF&PA SDPWS. Where Allowable Stress Design is used, table 2306.3(4) may be applied. Application of Table
4.3A of AF&PA SDPWS shall include the following:
1. Wood structural panel thickness for shear walls shall not be less than 3/8 inch thick. When 3/8 -inch or 7/16 -
inch thick panels are used, studs shall not be spaced at more than 16 inches on center.
2. The maximum nominal unit shear capacities for 3/8 inch wood structural panels resisting seismic forces is
400 pounds per linear foot (plf).
Exception: Other nominal unit shear capacities may be permitted if such values are substantiated by cyclic
testing and approved by the building official.
3. Where shear design values using Allowable Stress Design (ASD) exceed 350 plf or Load and Resistance
Factor Design (LRFD) exceed 500 plf, all framing members receiving edge nailing from abutting panels shall
not be less than a single 3 -inch nominal member, or two 2 -inch nominal members fastened together to transfer
the design shear value between framing members. Wood structural panel joint and sill plate nailing shall be
staggered at all panel edges. See Section 4.3.6.1 and 4.3.6.4.3 of AF&PA SDPWS for sill plate size and
anchorage requirements.
4. Nails shall be placed not less than 1/2 inch in from the panel edges and not less than 3/8 inch from the edge
of the connecting members for shear greater than 350 plf using ASD or 500 plf using LRFD. Nails shall be
placed not less than 3/8 inch from panel edges and not less than 1/4 inch from the edge of the connecting
members for shears of 350 plf or less using ASD or 500 plf or less using LRFD.
Application of Table 4.3B of AF&PA SDPWS shall not be permitted.
Application of Table 4.3C of AF&PA SDPWS shall not be permitted.
Shear walls using panels fastened with staples shall not be permitted.
Exception: Allowable shear values where panels are fastened to framing members with staples may be used if
such values are substantiated by cyclic testing and approved by the building official.
Panels complying with ANSI/APA PRP -210 shall be permitted to use design values for Plywood Siding in the
AF&PA SDPWS.
18.08.100 Section 2307.2 is Added
Section 2307.2 is added to read as follows:
2307.2 Wood -frame shear walls. Wood -frame shear walls shall be designed and constructed in accordance with
Section 2306.3 as applicable.
18.08.110 Table 2306.3(4) is Added
Table 2306.3(4) is added as follows:
41
M
TABLE 2306.3(4)
WOOD STRUCTURAL PANEL SHEAR WALLS with Framing of Douglas -Fir Larch or Southern Pine
Allowable (ASD) Shear Capacities (pounds per foot)
* Framing members and blocking at adjoining panels shall be 3 -inch nominal or greater where the required seismic shear capacity exceeds 350 plf.
** Framing members and blocking at adjoining panels shall be 3 -inch nominal or greater.
a. Where panels are applied on both faces of a wall and nail spacing is less than 6 inches o.c. on either side, panel joints shall be offset to fall on different
framing members, or framing shall be 3 -inch nominal or thicker at adjoining panel edges and nails at all panel edges shall be staggered.
b. Where the width of framing members is required to be 3 -inch nominal, two 2 -inch nominal members shall be permitted provided they are fastened together
to transfer the shear between members.
c. Where 3/8 -inch or 7/16' sheathing is used, studs shall not be spaced more than 16 inches on center. Otherwise, studs shall not be spaced at more than 24
inches on center.
d. Where studs are spaced at 24 inches o.c., nailing to intermediate framing shall be spaced at 6 inches o.c. maximum. Where studs are spaced less than 24
inches o.c., nailing to intermediate framing shall be spaced at 12 inches o.c. maximum.
e. Foundation anchor bolts shall have a steel plate washer under each nut not less than 0.229"x3"x3" in size. The hole in the plate washer shall be permitted to
be diagonally slotted with a width of up to 3/16' larger than the bolt diameter and a slot length not to exceed 1-3/4", provided a standard cut washer is
placed between the plate washer and the nut. See AF&PA SDPWS for additional information.
f. Allowable shear values for 7/16 -inch sheathing are permitted to be increased to values shown for 15/32 -inch sheathing with the same nailing provided
panels are applied with long dimension across studs.
g. Galvanized nails shall be hot dipped or tumbled.
42
Minimum
SEISMIC
WIND
Minimum
Fastener
Sheathing Material
Nominal
Panel
Penetration in
Nail Size
Panel Edge Fastener Spacing (in.)
Panel Edge Fastener Spacing (in.)
Framing
(common)
Thickness
Member or
6
4
3
2
6
4
3
2
(in.)
Blocking (in.)
3/8
200
200
200
200**
322
505
645
855**
Wood Structural
7/16
1-3/8
Sd
255
395*
505*
670**
357
552
707
937**
Panels — Structural
15/32
280
430*
550*
730**
392
602
770
1022**
15/32
1-1/2
lod
340
510*
665**
870**
475
715
930**
1217**
3/8
1-1/4
6d
200
200
200
200**
280
420
545
715**
3/8
200
200
200
200**
307
447
575
742**
Structural
Wood S al
tructu7/16
1-3/8
240
350
450*
585**
335
490
630
820**
Panels — Sheathing
15/32
8d
260
380*
490*
640**
365
532
685
895**
(DOC PS I or PS 2)
15/32
310
460*
600**
770**
435
645
840**
1077**
19/32
1-1/2
10d
340
510*
665**
870**
475
715
930**
1217**
1-1/4
W
140
200
200
200**
195
295
385
505**
Plywood Siding3/8
y
1-3/8
8d
160
200
200
200**
225
335
435
575**
* Framing members and blocking at adjoining panels shall be 3 -inch nominal or greater where the required seismic shear capacity exceeds 350 plf.
** Framing members and blocking at adjoining panels shall be 3 -inch nominal or greater.
a. Where panels are applied on both faces of a wall and nail spacing is less than 6 inches o.c. on either side, panel joints shall be offset to fall on different
framing members, or framing shall be 3 -inch nominal or thicker at adjoining panel edges and nails at all panel edges shall be staggered.
b. Where the width of framing members is required to be 3 -inch nominal, two 2 -inch nominal members shall be permitted provided they are fastened together
to transfer the shear between members.
c. Where 3/8 -inch or 7/16' sheathing is used, studs shall not be spaced more than 16 inches on center. Otherwise, studs shall not be spaced at more than 24
inches on center.
d. Where studs are spaced at 24 inches o.c., nailing to intermediate framing shall be spaced at 6 inches o.c. maximum. Where studs are spaced less than 24
inches o.c., nailing to intermediate framing shall be spaced at 12 inches o.c. maximum.
e. Foundation anchor bolts shall have a steel plate washer under each nut not less than 0.229"x3"x3" in size. The hole in the plate washer shall be permitted to
be diagonally slotted with a width of up to 3/16' larger than the bolt diameter and a slot length not to exceed 1-3/4", provided a standard cut washer is
placed between the plate washer and the nut. See AF&PA SDPWS for additional information.
f. Allowable shear values for 7/16 -inch sheathing are permitted to be increased to values shown for 15/32 -inch sheathing with the same nailing provided
panels are applied with long dimension across studs.
g. Galvanized nails shall be hot dipped or tumbled.
42
h. Nails shall be placed not less than 1/2 -inch in from the panel edges and not less than 3/8 -inch from the edge of the connecting members for shear greater
than 350 pit Nails shall not be placed not less than 3/8 -inch from panel edges and not less than 1/4 -inch from the edge of the connecting members for
shears of 350 pit or less.
i. See AF&PA SDPWS for the following: For general construction requirements see 4.3.6. For specific requirements see 4.3.7.1 for wood structural panel
shearwalls. See Appendix A for common nail dimensions.
j. For species and grades of framing other than Douglas -Fir -Larch or Southern Pine, reduced nominal unit shear capacities shall be determined by multiplying
the tabulated nominal unit shear capacity by the Specific Gravity Adjustment Factor= (I-(0.5-G)j, where G = Specific Gravity of the framing lumber from
the NDS (Table 11.3.2A). The Specific Gravity Adjustment Factor shall not be greater than 1.
k. See AF&PA SDPWS Table 4.3A for the apparent shear stiffness values G,.
43
18.08.120 Subsection 2308.3.4 is Amended
Subsection 2308.3.4 is amended to as follows:
Remove the exception to Subsection 2308.3.4.
18.0&130 Subsection 2308.9.3.1 is Amended
Subsection 2308.9.3.1 is amended as follows:
2308.9.3.1 Alternative bracing. Any bracing required by Section 2308.9.3 is permitted to be
replaced by the following:
In one-story buildings, each panel shall have a length of not less than 2 feet 8 inches (813
mm) and a height of not more than 10 feet (3048 mm). Each panel shall be sheathed on one
face with 15/32 -inch -minimum -thickness (11.9 mm) wood structural panel sheathing nailed
with 8d common nails spaced 3 inches on panel edges, 3 inches at intermediate supports.
Two anchor bolts installed in accordance with Section 2308.6 shall be provided in each panel.
Anchor bolts shall be placed at each panel outside quarter points. Each panel end stud shall
have a tie -down device fastened to the foundation, capable of providing an approved uplift
capacity of not less than 1,800 pounds (ASD) (8006 N). The tie -down device shall be
installed in accordance with the manufacturer's recommendations. The panels shall be
supported directly on a foundation or on floor framing supported directly on a foundation that
is continuous across the entire length of the braced wall line. This foundation shall be
reinforced with not less than one No. 4 bar top and bottom.
Where the continuous foundation is required to have a depth greater than 12 inches (305 mm),
a minimum 12 -inch by 12 -inch (305 mm by 305 mm) continuous footing or turned down slab
edge is permitted at door openings in the braced wall line. This continuous footing or turned
down slab edge shall be reinforced with not less than one No. 4 bar top and bottom. This
reinforcement shall be lapped 15 inches (381 mm) with the reinforcement required in the
continuous foundation located directly under the braced wall line.
18.08.140 Subsection 2308.9.32, and Figure 2308.9.3.2 are Amended
Subsection 2308.9.3.2, and Figure 2308.9.3.2 are amended as follows:
2308.9.3.2 Alternate bracing wall panel adjacent to a door or window opening. Any bracing
required by Section 2308.9.3 is permitted to be replaced by the following when used adjacent to a
door or window opening with a full-length header:
In one-story buildings, each panel shall have a length of not less than 16 inches (406 mm) and
a height of not more than 10 feet (3048 mm). Each panel shall be sheathed on one face with
15/32 -inch -minimum -thickness (11.9 mm) wood structural panel sheathing nailed with 8d
common nails spaced 3 inches on panel edges, 3 inches at intermediate supports and in
accordance with Figure 2308.9.3.2. The wood structural panel sheathing shall extend up over
the solid sawn or glued -laminated header and shall be nailed in accordance with Figure
2308.9.3.2. A built-up header consisting of at least two 2 x 12s and fastened in accordance
with Item 24 of Table 2304.9.1 shall be permitted to be used. A spacer, if used, shall be
placed on the side of the built-up beam opposite the wood structural panel sheathing. The
header shall extend between the inside faces of the first full-length outer studs of each panel.
The clear span of the header between the inner studs of each panel shall be not less than 6 feet
(1829 mm) and not more than 18 feet (5486 mm) in length. A strap with an uplift capacity of
not less than 1,000 pounds (ASD) (4,400 N) shall fasten the header to the inner studs opposite
the sheathing. One anchor bolt not less than 5/8 inch (15.9 mm) diameter and installed in
accordance with Section 2308.6 shall be provided in the center of each sill plate. The studs at
each end of the panel shall have a tie -down device fastened to the foundation with an uplift
capacity of not less than 4,200 pounds (ASD) (18 480 N).
Ur
M
Where a panel is located on one side of the opening, the header shall extend between the
inside face of the first full-length stud of the panel and the bearing studs at the other end of
the opening. A strap with an uplift capacity of not less than 1,000 pounds (ASD) (4400 N)
shall fasten the header to the bearing studs. The bearing studs shall also have a tie -down
device fastened to the foundation with an uplift capacity of not less than 1,000 pounds (ASD)
(4400 N).
The tie -down devices shall be an embedded strap type, installed in accordance with the
manufacturer's recommendations. The panels shall be supported directly on a foundation that
is continuous across the entire length of the braced wall line. This foundation shall be
reinforced with not less than one No. 4 bar top and bottom.
Where the continuous foundation is required to have a depth greater than 12 inches (305 mm),
a minimum 12 -inch by 12 -inch (305 mm by 305 mm) continuous footing or turned down slab
edge is permitted at door openings in the braced wall line. This continuous footing or turned
down slab edge shall be reinforced with not less than one No. 4 bar top and bottom. This
reinforcement shall be lapped not less than 15 inches (381 mm) with the reinforcement
required in the continuous foundation located directly under the braced wall line.
M
5O
EXTENT OF HEADER
DOUBLE PORTAL FRAME (TWO BRACED WALL PANELS)
EXTENT OF HEADER
SINGLE PORTAL FRAME (ONE BRACED WALL PANEL)
MIN. 3' X 11.25' NET HEADER l .. .
6' TO 10' i
FASTEN TOP PLATE TO HEADER WITH TWO TYPICAL PORTAL
ROWS OF 16D SINKER NAILS AT W O.C. TYP. 1000 LB FRAME
I STRAP CONSTRUCTION
•I
1000 LB STRAP OPPOSITE SHEATHING
J I FOR APANEL SPLICE
•,� FASTEN SHEATHING 70 HEADER WITH 8D COMMON OR OF NEEDED), PANEL 'I
tl GALVANIZED 80% NAILS IN 3' GRID PATTERN AS SHOWN AND
EDGES SHALL BE 1
MAX. i• BLOCKED, AND OCCUR
3'O.C. IN ALL FRAMING (STUDS, BLOCKING. AND SILLS)TVP.
MIGHT WITHIN 24'GF MID- _
10 •I ii HEIGHT. ONE ROW OF
i - MIN. WIDTH = IT FOR ONE STORY STRUCTURES TVP. SHEATHING-TO- i
MIN. WIDTH = 24' FOR USE IN THE FIRST OF TWO
FRAMING NAILING IS
Is0RV STRUCTURES REOUIRED. ? :a
IF 2%4 BLOCKING IS '!
MIN. 2x4 FRAMING MIN. !'
USED, THE 2X4'S MUST
i 316' MIN. THICKNESS WOOD DOUBLE BE NAILED TOGETHER
.I STRUCTURAL PANEL SHEATHING'- 2x4 POST WITH 3160 SINKERS
MIN. 4200 LB TIE-DOWN DEVICE (EMBEDDED INTO
' CONCRETE AND NAILED INTO FRAMING) MIN. 1000 LB
Ir - TIE DOWN -..,
SEE SECTION 2308.9.3.2 DEVICE
I f ! I f
For Sl: I foot = 304.8 mm: 1 inch = 25.4 mm: I pound = 4.443 N.
apa +q»4 GeN..i. pesly.0 paYD E M MO 1 "h 15 JKDnixnwnLYCF • 111 mm1ww4 wun»Ypaw1.M+11iq nYe4wM b<om.»n nN. yxa4l Mlw. en
p »I Opp ii YKM. a Ypmn»M�.uppal..
FIGURE 2308.9.3.2
ALTERNATE BRACED WALL PANEL ADJACENT TO A DOOR OR WINDOW OPENING
46
5I
18.08.150 Table 2308.12.4 is Amended
Table 2308.12.4 is amended to read as follows:
TABLE 2308.12.4
WALL BRACING IN SEISMIC DESIGN CATEGORIES D AND E
(Minimum Percentage of Wall Bracing per each 25 Linear Feet of Braced Wall Line a)
CONDITION
SHEATHING
TYPE
SDS <0.50
0.50:s Sos <
0.75
0.75:5 SDs <
1.00
SDS> 1.00
One Story
G -Pc
43
59
75
100
S -W,
21
32
37
48
a. Minimum length of panel bracing of one face of the wall for S -W sheathing shall be at least
4 feet long or both faces of the wall for G -P sheathing shall be at least 8 feet long; h/w ratio
shall not exceed 2:1. For S -W panel bracing of the same material on two faces of the wall,
the minimum length is permitted to be one-half the tabulated value but the h/w ratio shall
not exceed 2:1 and design for uplift is required.
b. G -P = gypsum board, portland cement plaster or gypsum sheathing boards; S -W = wood
structural panels.
c. Nailing as specified below shall occur at all panel edges at studs, at top and bottom plates
and, where occurring, at blocking:
For 1/2 -inch gypsum board, 5d (0.113 inch diameter) cooler nails at 7 inches on center;
For 5/8 -inch gypsum board, No 11 gage (0.120 inch diameter) cooler nails at 7 inches on
center;
For gypsum sheathing board, 1-3/4 inches long by 7/16 -inch head, diamond point
galvanized nails at 4 inches on center;
For gypsum lath, No. 13 gage (0.092 inch) by 1-1/8 inches long, 19/64 -inch head,
plasterboard at 5 inches on center;
For Portland cement plaster, No. 11 gage (0.120 inch) by 1-1/2 inches long, 7/16 -inch
head at 6 inches on center;
d. S -W sheathing shall be 15/32 -inch thick nailed with 8d nails placed 3/8 -inch from panel
edges and spaced at 6 -inches / 12 -inches (edges / field).
18.08.160 Subsection 2308.12.5 is Amended
Subsection 2308.12.5 is amended to read as follows:
2308.125 Attachment of sheathing. Fastening of braced wall panel sheathing shall not be less
than that prescribed in Table 2308.12.4 or 2304.9.1. Wall sheathing shall not be attached to
framing members by adhesives. Staple fasteners in Table 2304.9.1 shall not be used to resist or
transfer seismic forces in structures assigned to Seismic Design Category D, E or F.
Exception: Staples may be used to resist or transfer seismic forces when the allowable shear
values are substantiated by cyclic testing and approved by the building official.
All braced wall panels shall extend to the roof sheathing and shall be attached to parallel roof
rafters or blocking above with framing clips (18 gauge minimum) spaced at maximum 24 inches
(6096 mm) on center with four 8d nails per leg (total eight 8d nails per clip). Braced wall panels
shall be laterally braced at each top comer and at maximum 24 inches (6096 mm) intervals along
the top plate of discontinuous vertical framing.
47
62-
Chapter 18.09
AMENDMENTS TO CHAPTER 25; GYPSUM BOARD AND PLASTER, OF THE
CALIFORNIA BUILDING CODE
Sections:
18.09.005 Chapter 25 is Amended
18.09.010 Subsection 2512.1.2 is Amended
18.09.005 Chapter 25 is Amended.
The following sections of Chapter 25 of the California Building Code, as adopted by Chapter 18.01
hereof, are added, deleted, or amended as follows:
18.09.010 Subsection 2512.1.2 is Amended
Subsection 2512.1.2 is amended to read as follows:
2512.1.2 Weep screeds. A minimum 0.019 -inch (0.5mm) (No. 26 galvanized sheet gage),
corrosion -resistant weep screed or plastic weep screed, with a minimum vertical attachment flange
of 3'h inches (89 mm) shall be provided at or below the foundation plate line on exterior stud walls
in accordance with ASTM C 926. The weep screed shall be placed a minimum of 4 inches (102
mm) above the earth or 2 inches (51 mm) above paved areas and shall be of a type that will allow
trapped water to drain to the exterior of the building. The weather -resistant barrier shall lap the
attachment flange. The exterior lath shall cover and terminate on the attachment flange of the weep
screed.
M
5�
Chapter 18.10
AMENDMENTS TO APPENDIX G; FLOOD -RESISTANT CONSTRUCTION, OF
THE CALIFORNIA BUILDING CODE
Sections:
18.10.005
Appendix G is Amended
18.10.010
Subsection G101.4 is Amended
18.10.020
Subsection G102.2 is Amended
18.10.030
Subsection G104.1 is Amended
18.10.040
Subsection G301.1 is Amended
18.10.050
Subsection G901.1 is Amended
18.10.060
Subsection G901.2 and G901.3 are deleted
18.03.005 Appendix G is Amended.
The following sections of Appendix G of the California Building Code, as adopted by Chapter 18.01
hereof, are added, deleted, or amended as follows:
18.10.010 Subsection G101.4 is Amended
Subsection G101.4 is amended to read as follows:
G101.4 Violations. Any violation of a provision of this chapter or the City of Santa Clarita
Flood Plain Ordinance, or failure to comply with a permit or variance issued pursuant to this
chapter or any requirement of this chapter, shall be subject to the provisions of Section 114 of
this code.
18.10.020 Subsection G102.2 is Amended
Subsection G102.2 is amended to read as follows:
G102.2 Establishment of flood hazard areas. Flood hazard areas are established as outlined
in Section 1612.3 of this code.
18.10.030 Subsection G104.1 is Amended
Subsection G104.1 is amended to read as follows:
G104.1 Required. Any person, owner or authorized agent who intends to conduct any
development in a flood hazard area shall first make application to the building official for
such work. No permit shall be issued until the applicant demonstrates they have fully
complied with all applicable Federal, State, and local requirements pursuant to such work
within a flood hazard area.
18.10.040 Subsection G301.1 is Amended
Subsection G301.1 is amended to read as follows:
G301.1 General. Any subdivision proposal or other proposed new development in a flood
hazard area shall be reviewed to assure that:
(no change to the three items listed under this subsection)
18.10.050 Subsection G901.1 is Amended
Subsection G901.1 is amended to read as follows:
49
51t
G901.1 Temporary Structures. A temporary structure, for the purposes of this section, is a
structure that is erected for a period of less than 180 days. Temporary structures and
temporary storage in floodways are not permitted in the City of Santa Clarita.
18.10.060 Subsection G901.2 and G901.3 are deleted
Subsection G901.2 and G901.3 are deleted in their entirety.
50
IM
Chapter 18.11
AMENDMENTS TO CHAPTER 1 DIVISION II; ADMINISTRATION,
OF THE CALIFORNIA RESIDENTIAL CODE
Sections:
18.11.005
Chapter 1 Division II is Amended
18.11.010
Subsection R101.1 is Amended
18.11.020
Subsection R102.4.3 is Added
18.11.030
Subsection R102.7.1 is Amended
18.11.040
Subsections R102.7.1.1 and R102.7.1.2 are added
18.11.050
Subsection R105.2 is Amended
18.11.060
Subsection R105.2.2 is Amended
18.11.005 Chapter 1 Division II is Amended.
The following sections of Chapter 1 Division II of the California Residential Code, as adopted
by Chapter 18.01 hereof, are added, deleted, or amended as follows:
18.11.010 Subsection R101.1 is Amended
Section R101.1 is hereby amended to read as follows:
R101.1 Title. These regulations, including all duly adopted local amendments, shall become a
part of the City of Santa Clarita Building Code and may also be referred to as the Santa Clarita
Residential Code for One- and Two-family Dwellings, and shall hereinafter be referred to as `this
code'.
18.11.020 Subsection R102.4.3 is Added
Section R102.4.3 is hereby added to read as follows:
R102.4.3 Local amendments. The amendments to Chapter 1, Division II Scope and
Administration of the California Building Code, as adopted at the local level, shall also apply to
projects regulated by the California Residential Code at the local level and shall be considered
part of this code.
18.11.030 Subsection R102.7.1 is Amended
Section R102.7.1 is hereby amended to read as follows:
R102.7.1 Additions, Alterations, or Repairs. Additions, alterations, or repairs to any structure
shall conform to the requirements for a new structure without requiring the existing structure to
comply with all of the requirements of this code except as outlined in subsections R102.7.1.1 and
R102.7.1.2. Additions, alterations, or repairs shall not cause an existing structure to become
unsafe or adversely affect the performance of the building.
18.11.040 Subsections R102.7.1.1 and R102.7.1.2 are added
Subsections R102.7.1.1 and R102.7.1.2 are hereby added to read as follows:
R102.7.1.1 Substantial improvement. Where the proposed work includes any demolition,
alteration, or repair of more than 50% of the existing building or component of the building,
the remaining portion of the building or building component shall be upgraded to comply
51
5l�
with the structural provisions, as well as fire and life safety provisions of this code in such
cases where it is determined by the Building Official that the existing portions of the building
are substantially deficient or pose a significant hazard.
When determining the percentage of demolition, alteration or repair, one of the following
methods shall be applied, at the discretion of the Building Official:
a. A comparison of the square footage, lineal footage, or number of components or fixtures
of the proposed demolition, alteration or repair to the total square footage, lineal footage,
or number of components or fixtures, as may be applicable.
b. A comparison of the valuation of the proposed demolition, alteration or repair to the
valuation of the existing building.
The provisions of this section shall be cumulative over any 12 month period.
R102.7.1.2 Substantial addition. Where the proposed work includes addition of new floor
area that is greater than 100% the existing building floor area, the existing portion of the
building shall be upgraded to comply with the structural provisions, as well as fire and life
safety provisions of this code in such cases where it is determined by the Building Official
that the existing portions of the building are substantially deficient or pose a significant
hazard.
When determining the floor area of the existing building, the area of the garage or other
unconditioned spaces shall not be included in the total area.
The provisions of this section shall be cumulative over any 12 month period.
18.11.050 Subsection R105.2 is Amended
Subsection R105.2 is amended to read as follows:
R105.2 Work Exempted from Permit. Exemptions from permit requirements of this code shall
not be deemed to grant authorization for any work to be done in any manner in violation of the
provisions of this code or any other laws or ordinances of the City of Santa Clarita including such
requirements as may be established by any City department or division or the requirements of any
other governing agency. Unless otherwise exempted, separate plumbing, electrical, and
mechanical permits will be required for any such items exempted herein.
For a complete list of work that is exempt from a permit refer to Section 18.02.040 of the SCMC
amending section 105.2 Work Exempted from Permit in the 2013 California Building Code.
18.11.060 Subsection R105.2.2 is Amended
Subsection 105.2.2 is amended to read as follows:
105.2.2 Repairs and Maintenance. Application or notice to the Building Official is not
required for ordinary maintenance or repairs to structures. In no case shall the repair or
maintenance work create an unsafe condition or violate any provision of State code. Such
repairs shall not include the cutting away of any wall, partition or portion thereof, the removal
or cutting of any structural beam or load-bearing support, or the removal or change of any
required means of egress, or rearrangement of parts of a structure affecting the egress
requirements.
For a complete list of maintenance or repairs that are exempt from a permit, refer to Section 18.02.050
of the SCMC amending subsection 105.2.2 Repairs and Maintenance in the 2013 California
Building Code,
52
6-1
Chapter 18.12
AMENDMENTS TO CHAPTER 3; BUILDING PLANNING,
OF THE CALIFORNIA RESIDENTIAL CODE
Sections:
W1HO DESIGN
18.12.005
Chapter 3 is Amended
18.12.010
Subsection R301.1.3.2 is Amended
18.12.020
Subsection R301.1.4 is Added
18.12.030
Table R301.2(1) is Amended
18.12.040
Table R301.2.2.1.1 is Amended
18.12.050
Subsection R301.2.2.2.5 is Amended
18.12.060
Subsection R301.2.2.3.8 is Added
18.12.005 Chapter 3 is Amended.
The following sections of Chapter 3 of the California Residential Code, as adopted by Chapter
18.01 hereof, are added, deleted, or amended as follows:
18.12.010 Subsection R301.1.3.2 is Amended
Subsection R301.1.3.2 is amended to read as follows:
R301.1.3.2 Woodframe structures. The building official shall require construction documents to
be approved and stamped by a California licensed architect or engineer for all dwellings of
woodframe construction more than one story in height or with a basement.
18.12.020 Subsection R301.1.4 is Added
Subsection R301.1.4 is added to read as follows:
R301.1.4 Seismic design provisions for buildings constructed on or into slopes steeper than
one unit vertical in three units horizontal (33.3 percent slope). The structural design and
construction of new buildings and additions to existing buildings when constructed on or into
slopes steeper than one unit vertical in three units horizontal (33.3 percent slope) shall comply
with the California Building Code.
18.12.030 Table R301.20) is Amended
Table R301.2(1) is amended as follows:
fd10UX0
mow
W1HO DESIGN
SEISMIC
DESIGN
SUBIER TO DAMAGE
FROM
WINTER
DESIGN
ICE
UNDERBARRIER
EN
FLOOD
HKARDSS
RIR
FREEZING
NEAN
ANNUAL
Fust
LORD
Speed°Tppographk
CI1TEGO0.r�
Weammi g.
[Ine
Temdte`
TENp'
REQU EDh
DIDE]t�
TEMW
(mph)
effects
depths
0
85
1 NONE
Dz,E
NEGLIGIBLE
12"
MWERA
40 F
NO
note
0
66 F
a. Weathering may require a higher strength concrete or grade of masonry than necessary to satisfy
the structural requirements of this code. The weathering column shall be filled in with the
weathering index (i.e., "negligible," "moderate" or "severe) for concrete as determined from the
Weathering Probability Map [Figure R301.2(3)]. The grade of masonry units shall be determined
from ASTM C 34, C 55, C 62, C 73, C 90, C 129, C 145, C 216 or C 652.
b. The frost line depth may require deeper footings than indicated in Figure R403.1(1). The
jurisdiction shall fill in the frost line depth column with the minimum depth of footing below
finish grade.
c. The jurisdiction shall fill in this part of the table to indicate the need for protection depending on
whether there has been a history of local subterranean termite damage.
53
W
d. The jurisdiction shall fill in this part of the table with the wind speed from the basic wind speed
map [Figure R301.2(4)AI. Wind exposure category shall be determined on a site-specific basis in
accordance with Section R301.2.1.4.
e. Temperatures shall be permitted to reflect local climates or local weather experience as
determined by the building official.
f. The jurisdiction shall fill in this part of the table with the seismic design category determined
from Section R301.2.2.1.
g. Date of entry into the National Flood Insurance Program: April 25, 1980. Date of the Flood
Insurance Study: April 25, 1980. Panel numbers and dates of all currently effective FIRMS and
FBFMs or other flood hazard map adopted by the authority having jurisdiction, as amended: all
panels for Community 060729.
h. In accordance with Sections R905.2.7.1, R905.43.1. R905.5.3.1, R905.6.3.1, R905.7.3.1 and
R905.8.3.1, where there has been a history of local damage from the effects of ice damming, the
jurisdiction shall fill in this part of the table with "YES" Otherwise, the jurisdiction shall fill in
this part of the table with "NO."
L The jurisdiction shall fill in this part of the table with the 100 -year return period air freezing
index (BF -days) from Figure R403.3(2) or from the 100 -year (99 percent) value on the National
Climatic Data Center data table "Air Freezing Index -USA Method (Base 32°F)' at
www.ncdc.noaa.gov/fpsf.html.
j. The jurisdiction shall fill in this part of the table with the mean annual temperature from the
National Climatic Data Center data table "Air Freezing Index -USA Method (Base 320F)' at
www.ncdc.noaa.gov/fpsf.htm].
k. In accordance with Section R301.2.1.5, where there is local historical data documenting
structural damage to buildings due to topographic wind speed-up effects, the jurisdiction shall fill
in this part of the table with "YES" Otherwise, the jurisdiction shall indicate "NO" in this part of
the table.
18.12.040 Table R301.2.2.1.1 is Amended
Table R301.2,11.1 is amended as follows:
TABLE R301.2.2.1.1
SEISMIC DESIGN CATEGORY DETERMINATION
CALCULATED SDs
SEISMIC DESIGN CATEGORY
SDs < 0.17g
A
0.17g < SDs <_ 0.33g
B
0.338 < SDs <_ 0.50g
C
0.509 < SDs < 0.67g
Do
0.678 < SDS15 0.83g
D,
0.83g < SDs <_ 1.00g
D2
1.00g < SDs
E
18.12.050 Subsection R301.2.2.2.5 is Amended
Subsection R301.2.2.2.5 is amended as follows:
Remove the exception to condition 1.
Condition 3 is amended to read as follows:
3. When the end of a braced wall panel occurs over an opening in the wall below.
Remove the exception to condition 3.
Remove the exceptions to condition 5.
54
5q
18.12.060 Subsection R301.2.2.3.8 is Added
Subsection R301.2.2.3.8 is added as follows:
R301.2.2.3.8 Anchorage of Mechanical, Electrical, or Plumbing Components and
Equipment. Mechanical, electrical, or plumbing components and equipment shall be anchored to
the structure. Anchorage of the components and equipment shall be designed to resist loads in
accordance with the International Building Code and ASCE 7, except where the component is
positively attached to the structure and flexible connections are provided between the component
and associated ductwork, piping, and conduit; and either
1. The component weighs 400 lb (1,780 N) or less and has a center of mass located 4 It or
less above the supporting structure; or
2. The component weighs 20 lb (89N) or less or, in the case of a distributed system, 5 lb/ft or
less.
55
Chapter 18.13
AMENDMENTS TO CHAPTER 4; FOUNDATIONS,
OF THE CALIFORNIA RESIDENTIAL CODE
Sections:
18.13.005
Chapter 4 is Amended
18.13.010
Section R401.1 is Amended
18.13.020
Subsection R403.1.2 is Amended
18.13.030
Subsection R403.1.3 is Amended
18.13.040
Subsection R403.1.4 is Amended
18.13.050
Subsection R403.1.5 is Amended
18.13.060
Subsection R403.1.6.2 is Added
18.13.070
Subsection R404.2 is Amended
18.13.005 Chapter 4 is Amended.
The following sections of Chapter 4 of the California Residential Code, as adopted by Chapter
18.01 hereof, are added, deleted, or amended as follows:
18.13.010 Section R401.1 is Amended
Section R401.1 is amended to read as follows:
R401.1 Application. The provisions of this chapter shall control the design and construction of
the foundation and foundation spaces for all buildings. In addition to the provisions of this
chapter, the design and construction of foundations in areas prone to flooding as established by
Table R301.2(l) shall meet the provisions of Section R322. Wood foundations shall not be
permitted.
18.13.020 Subsection R403.1.2 is Amended
Subsection R403.1.2 is amended to read as follows:
R403.1.2 Continuous footing in Seismic Design Categories Do, D, and D2. The braced wall
panels at exterior walls of buildings shall be supported by continuous footings. All required
interior braced wall panels in buildings shall be supported by continuous footings.
18.13.030 Subsection R403.1.3 is Amended
Subsection R403.1.3 is amended to as follows:
Remove the exception to subsection R403.1.3.
18.13.040 Subsection R403.1A is Amended
Subsection R403.1.4 is amended to read as follows:
R403.1.4 Minimum Depth. Where a geotechnical report is not provided and the presence of
expansive soils is unknown, the minimum depth of footings shall be 24 inches (610 mm) for
exterior walls and 18 inches (458 mm) for interior bearing walls. Such footings shall be reinforced
with two *4 rebar at the top and two #4 rebar at the bottom.
Exception: The minimum footing depth for unoccupied group U structures or patio structures
associated with an R-3 occupancy shall be 12 inches (305 mm).
Otherwise, the minimum depth of footings below the undisturbed ground surface shall be 12
inches (305 mm). Where applicable, the depth of footings shall also conform to Sections
R403.1.4.1 through R403.1.4.2.
18.13.050 Subsection R403.1.5 is Amended
Subsection R403.1.5 is amended to read as follows:
R403.1.5 Slope. The top surface of footings shall be level. The bottom surface of footings shall be
permitted to have a slope not exceeding one unit vertical in 10 units horizontal (]0 -percent slope).
Footings shall be stepped where it is necessary to change the elevation of the top surface of the
footing or where the surface of the ground slopes more than one unit vertical in 10 units horizontal
(10 -percent slope).
Stepped footings shall be reinforced with two #4 rebar at the top and two #4 rebar at the bottom.as
shown in Figure R403.1.5.
FIGURE R403.1.5
RECO ffND: a> 1
b sTV
2-X4 REBAR UOP & DOTTOH)
i I -. ,-BOTTOM PL,9TE (M)
GRADE
STEPPED FOUtiDVIONS
18.13.060 Subsection R403.1.6.2 is Added
Subsection R403.1.6.2 is added as follows:
R403.1.6.2 Light -gage mudsill anchors. Light -gage mudsill anchors which are intended to be
bent upon installation shall not be used to anchor braced walls. Where light -gage anchors are
used at exterior non -braced walls, they shall be fully protected by the exterior weather barrier
assembly or by an approved corrosion -resistant coating.
18.13.070 Subsection R404.2 is Amended
Subsection R404.2 is amended to read as follows:
R404.2 Wood foundation walls. Wood foundation walls shall not be permitted.
57 IA
lY
Chapter 18.14
AMENDMENTS TO CHAPTER 5; FLOORS,
OF THE CALIFORNIA RESIDENTIAL CODE
Sections:
18.14.005
Chapter 5 is Amended
18.14.010
Section R501.1 is Amended
18.14.020
Subsection R503.2.4 is Added
18.14.030
Figure R503.2.4 is Added
18.14.005 Chapter 5 is Amended.
The following sections of Chapter 5 of the California Residential Code, as adopted by Chapter
18.01 hereof, are added, deleted, or amended as follows:
18.14.010 Section R501.1 is Amended
Section R501.1 is amended to read as follows:
R501.1 Application. The provisions of this chapter shall control the design and construction of
the floors for all buildings including the floors of attic spaces used to house mechanical or
plumbing fixtures and equipment. Mechanical or plumbing fixtures and equipment shall be
attached (or anchored) to the structure in accordance with Section 8301.2.2.3.8.
18.14.020 Subsection R503.2A is Added
Subsection R503.2.4 is added to read as follows:
R503.2.4 Openings in horizontal diaphragms. Openings in horizontal diaphragms with a
dimension perpendicular to the joist that is greater than 4 feet (1.2 m) shall be constructed in
accordance with Figure R503.2.4.
58
18.14.030 Figure 8503.2.4 is Added
Figure R503.2.4 is added:
PLYWOOD SHEATHING
METAL TIE 16GA. x I Mr. 4'-0' MIN., (4 TOTAU
WI 16-16d COMMON NAILS ASSHOWN -
rl�
METAL TIE 16GA. x 1 I r x (OPENING WIDTH. 4'-0') MAN.,
(2TOTAL) W/2416d COMMDNNAILS
Tv Sl: 1 Ian = 25A mm, 1 Iwi = .MN.6 mm.
FIGURE R503.2.4
OPENINGS IN HORIZONTAL DIAPHRAGMS
59
w
Chapter 18.15
AMENDMENTS TO CHAPTER 6; WALL CONSTRUCTION,
OF THE CALIFORNIA RESIDENTIAL CODE
Sections:
18.15.005
Chapter 6 is Amended
18.15.010
Subsection R602.3.2 is Amended
18.15.020
Table R602.3(1) is Amended
18.15.030
Table R602.3(2) is Amended
18.15.040
Table R602.10.3(3) is Amended
18.15.050
Table R602.10.4 is Amended
18.15.060
Table R602.10.5 is Amended
18.15.070
Figure R602.10.6.1 is Amended
18.15.080
Figure R602.10.6.2 is Amended
18.15.090
Figure R602.10.6.4 is Amended
18.15.100
Subsection R602.10.9.1 is Deleted
18.15.110
Subsection R606.2.4 is Amended
18.15.120
Subsection R606.12.2.2.3 is Amended
18.15.005 Chapter 6 is Amended.
The following sections of Chapter 6 of the California Residential Code, as adopted by Chapter
18.01 hereof, are added, deleted, or amended as follows:
18.15.010 Subsection R602.3.2 is Amended
Exception of subsection R602.3.2 is amended as follows:
Remove the exception to subsection R602.3.2.
18.15.020 Table R602.3(1) is Amended
Table R602.3(1) is amended as follows:
Add new footnote k to Table R602.30)
k. Staples shall not be permitted for braced wall sheathing.
18.15.030 Table R602.3(2) is Amended
Table R602.3(2) is amended as follows:
Add new footnote h to Table R602.3(2)
h. Staples shall not be permitted for roof, floor, or wall sheathing.
.►
(�5
18.15.040 Table R602.10.3(3) is Amended
Table R602.10.3(3) is amended as follows:
TABLE R602.10.3(3)
BRACING REQUIREMENTS BASED ON SEISMIC DESIGN CATEGORY
IAS A FUNCTION OF BRACED WALL LINE LENGTH)
SOIL CLASS De
WALL HEIGHT- 10 FT
10 PSF FLOOR DEAD LOAD
15 PSF ROOF'CEILING DEAD LOAD
BRACED WALL LINE SPACINGS 25 FT
MINIMUM TOTAL LENGTH geed OF BRACED WALL PANELS REQUIRED
ALONG EACH BRACED WALL LINE
Seismic Design
Cae9ory
ISDQ
Story Loudon
Braced Wall
Line Length
Method LIB
Methode4
GB.
PCP
Method WSP
Condnnous
Sheathing
7�
10
NP
8
2.5
2.1
20 NP 16 5.0
4.3
30 NP 24 7.5
64
40 NP 32 10.0
8.5
50 NP 40 12.5
10.6
SDCD
2
^ 1'T
LFJ? L®•I
10
NP
NP
5.5
4.7
20 NP NP 110
94
30 NP NP 16.5
14.0
40 NP NP 22.0
18.7
50 NP NP 275
23.4
I[LJJI
B Q
10
NP
NP
NP
NP
20 NP NP NP
NP
30 NP NP NP
NP
40 NP NP NP
NP
50 NP NP NP
NP
a Wal bracing axgtlts are Cased m a sos sde dass'D'
D. FOlaldaUon aipple Wall Panels aha be brxed in awadence with section R611210.9
C. mehods Of bracing shall Ce as described in Sections R602.10.2, 8602.10.4, and 8602.10.5.
d. Methods GB and PCP braced was panel hAv IaM shall not exceed 1:1. McMMs DWB, SFB, PBS, and HPS ate not p&miftd
61
18.15.050 Table R602.10.4 is Amended
Table R602.10.4 is amended as follows:
TABLE R602.10.4
INTERMITTENT BRACING METHODS
WSP
Wood slrudwa l panel
(see Section fl pan[14)
15(32'
FIGURE
6tl common (2-12' z 0.131')
nails at 6' (panel edges) and
12' (intermediate), 3/6' edge
tllstance to panel edge.
Nails or screws at 7' spacing at
CS.WSP
Woad structuralanal
P
15132.
panel stiles including lop and
bottom plates; for all braced wall
�/'
panel locations for exterior
GS
Gypsum board
YP
o
ahemhing nail or straw size, vac
CS,G
to ganga openings and
150'
Table R602.30); for mlonor
suppoding roof load only A
_
w
gypsum board nal or screw size,
CS -PF
Continuous podal frame
See Section
R602. 10.4.1.1
see Table R702 3 5
1s/e ',11gage''/head nails at
PCP
Portland cement
Sae Section R703.6
w
16
plaster
For maximum 16' stud spacing
6'spacng
CONTINUOUS SHEATHING METHODS
METHOD
MATERIAL
MINIMUM THICKNESS
FIGURE
CONNECTION CRITERIA
Bd common We 0.113') nails
CS.WSP
Woad structuralanal
P
15132.
at S" spacing (panel edges) and
at 12'spacing (intermediate
supports)
Wood svuclural panel adjacent
CS,G
to ganga openings and
150'
Sea Method CS-WSP
suppoding roof load only A
_
w
CS -PF
Continuous podal frame
See Section
R602. 10.4.1.1
See Section
R602. 10.4.1.1
w
a. Applies to one well of a garage only.
b. Roof covering dead Inside shall be 3 psf or less.
62
(P-1
18.15.060 Table 8602.10.5 is Amended
Table R602.10.5 is amended as follows:
TABLE R602.10A
MINIMUM LENGTH OF BRACED WALL PANELS
METHOD
(BM Table R602.10.4)
aba
MINIMUM LENGTH'
nchaq
WWI Hoght
6tm lotwt I It be
12Mt
OONfRIBI1nfM LENGTH
onct w)
DWB. WSP. SFB. PBS, PCP. HP5. BV -W SP
48
38
48
53
58
Actuar
GB
48
48
48
53
58
Double sided- .Actual
Single sided -0.5 x Actual
LIB
55
62
69
NP
NP
Actual'
ABN'
SDC A. B and C.
wind speed < 110 mph
18
32
34
38
42
J8
SDC D,. D., and D., 12 12 34 NP NP
wind sped c 110 mph
Suppi'aing nx,f only
-Hrag I
+fra4
46 -iA
-Ill`
-261-
48
PIN
SupPxiing one wiry and nxii
23
TO
24
48
PI.G
24
27
3U
33'
361
1.5 x Actual'
CS-(;
24
27
70
33
36
Actual'
CS -111;
4+.211
t1F24
-24-21
- i 2p
24`
Actual'
.xdlx m.kar,Wmnp hetybl
i inchcsl
CS-WSP. CS•SPB
! 464
24
27
30
33
36
Actual'
68 26 27 30 33 36
72 27 27 10 33 76
76 30 29 30 33 36
80 32 30 .10 13 36
84 15 32 32 33 %
88 38 35 33 .13 36
92 43 77 35 35 .%
96 48 41 38 36 36
If1U — 44 40 38 38
Ite1 — 49 43 40 39
lux — 54 46 43 41
112 — — --A 45 43
116 — — 55 48 45
120 ....... — 60 52 48
114 — — — 56 SI
128 — — — 61 54
132 — 66 58
116 _... — _.. __ 62
140 — — — — h6
143 — — — — 72
Rw SI1 inch = 2}.4 mm. I t,44=-104-8 Minn. I mile Per ll0m = n.ut mn.
NP = N,x Pemuu J.
a. Lirw•ar innvlx>f:uiun Wall he Permitted.
b. Vsc the actual knish when it is greater than.x equal u+uw minimum knpth.
C. Maximum header hnyhs fm pill is I0 fret in xc<wdance with figure 14602.10.6.1. Wx wall height may M mcnaseJ to I2 feet with p, ry wall.
d. Maximum tivning hell4st few PFG is its less in ac.mdame w dh Figure R602.I0.6.1. His wall height may M tnemassti to 12 feel wgh Pmy will.
V. Maximum,gcning height I'nr CS4'f is 10 It" in xnvxdmwe with Figure R612. 10.6.4, but wall height may be irnnmed W 12 feet with Piny wag.
63
18.15.070 Figure R602.10.6.1 is Amended
Figure R602.10.6.1 is amended as follows:
F.IIEL LE14GTHPEA
PIE R60T 105
1=
MBI d4�Woon
STRUCTURAL PANEL
SHEATHNG ON ONE FACE
MA
DOL&F STUDS REOUIREO
PANEL MUST BE ATTACKED
TO CONCRETE F DOTING OR
CONCRETE FOW/DATION
WALL CONTINUOUS OVER
BRACEC'NALL LINE
12,117 DIAMETER ANCHOR
BOLTS LOCATED BETWEEN
6' AND 12' Of EACH END I --
THE SEGMENT
TOP PLATE SHALL BE CONTINUOUS
OVER BRACED WALL PANEL
FOR PANEL SPLICE OF NEEDED;
ADIOINNG PANEL EDGES SMALL MEET
OVER AND BE FASTENED TO COMMON
FRAMING
80 COMMON SR 1:10 08% NAILS 0 I
OC AT PANEL EDGES FOR SINGLE
STORY AMC d r C PANEL EDGES
F OR THE FAST OF 2 STORIES
VUL4 AIDER HEADER AS REWIRED
80 COMMON41RL44V-RA NAILS 0 TY
0 C AT IFTERICR SUPPORTS
MRI REFIF ORIGIN. OF FOUNDATION,
ONE a BAR TOP AND BOTTOM W
BARSt M'NFIUB
ZE
MINIMUM FOO'ING S12E. DICER
OPENING IS 12"112 AINRES BBVW
91 6N 6
FIGURE R602.10.6.1
METHOD ABW—ALTERNATE BRACED WALL PANEL
64
18.15.080 Figure R602.10.6.2 is Amended
Figure R602.10.6.2 is amended as follows:
IWIN 60[.T NO MNEAOER WIM0
tOMu0.Y OR OE.LvanQFO 60%NAR91N 7" 0RID
PaTtf A%aS"IMN
aEAOEN 1 NII.I.JO EOf PERTnG_ _
R60} SIt f ID OF SNDE.N OLE NING
ONP061tE SHOE OF 6xFATXIMO
WIN r$1a1N 169TArbdv9t MWOd TYNJ
IISMSEVVE0 INTO CONCAETL ANO NNlEOIPM
IROYINM'
.*'CO"NG vn UNDER CitNIN619R-z@A1V .
W`MX Slip P Att 6E PER.7TEC cT 0000. OPENINGS
Iln rI164GUNCTER ANCx OR 60'.T 0.6TµtE04ER
WLt 1 EWIMY%i'%llIX'PIATE WAfiKR
FRONT ELEVATION
FIGURE R602.10.6.2
METHOD PFH—PORTAL FRAME WITH HOLD-DOWNS
AT DETACHED GARAGE DOOR OPENINGS
65
SFCTICN
fMTENTO,
PLATE TC
XEROfA.1.
Two
ROW, Of ISO
SiNR(R NIN31T
06."I
1fflz
NIX - VOOO
STXU[T1Ek
.ift
9xEA•e1N6
18.15.090 Figure R602.10.6A is Amended
Figure R602.10.6.4 is amended as follows:
URrvY:F N� ip w"+$NGt4 axR1.4i WJN
fpCi�+.N♦Ia*.6r
eCy NtiGLE 3[CC4NFYA�.L
SJvpAxC964WNQYx MU. XF45 N i 3N9
YaRpv.i hCEx
\_ N[10Et leln:V.DN.fT4l9 TVLf —
M/ELTNu[q NINT4Ne
� 8w OWBt[4%NR.MI�eG61NIEE WnN Wt
1ZZ iNNene1tM00p @IFVCryI{♦\6HeL
P!!NMPF
>T 7 .c CM1NRt CM1ON`INIC6B
ar.ww sac Isrupwwa swE
YLLYVeX. AVO SLLL SYv.
�— MX..U6h Ci WNi1YG INCL NL:'S.1
�.-........ My ]I'Yp.MErER YiCNCR 6Ct�Y
.VSIKtiC Ma Mp)vS.HYNyxYvi.{Wyq
YlSrtv
WF N CON4NF 14 nN NPSg1N8 NIOCE f W INlflldl
OVENMMDW I`L O iRNlp NNCNOROVYIOY
mrtn wYrt srLAMNB cua rror I.v ova pvc xN NN.4NY1
ggs
FRONT ELEYAPOH
Fw SI: I iM6=25,4 mm.I fix =t M.6 mm.
YpNlpt OTM lE{
HtEpS'80.
NNMeMrt<EAE
'3 Wf+.MtXh -
♦ceewuiuvt
AIM �YeCD fITWEN^:1
•NZ19
Y ppYx vurcx
N•vcapwa fxf..
CCC u. axOp
<TIW16 to
CpNOv LC4INFA
N�INN I.'MM4t
tC. N81OYl.G1Y 11eV/
OF S'OC.NIYMtlIS
IRQp®NIKn
8YIf5E00E.
N.N pWgE Ba. VCBT
RN3 Nfa YLNt0.S 1.
X -4M p �ALx
YNGp/YY rltlff
.±05�If;S
1M1PoA
pCT.N.W'P
SECTION
FIGURE R602.10.6.4
METHOD CS -PF -CONTINUOUSLY SHEATHED PORTAL FRAME PANEL CONSTRUCTION
YY(WCTLfNY.NSI
YxU'xINY
66 �\
18.15.100 Subsection R602.10.9.1 is Deleted
Subsection R602.10.9.1 is deleted in its entirety.
18.15.110 Subsection R606.2.4 is Amended
Subsection R606.2.4 is amended to read as follows:
R606.2.4 Parapet walls. Masonry parapet walls shall be reinforced in accordance with Section
R606.12.
18.15.120 Subsection R606.12.2.2.3 is Amended
Subsection R606.12.2.2.3 is amended to read as follows:
R606.12.2.2.3 Reinforcement of requirements for masonry elements. Masonry elements listed
in Section R606.12.2.2.2 shall be reinforced in either the horizontal or vertical direction as shown
in Figure R606.11(3) and in accordance with the following:
1. Horizontal reinforcement. Horizontal joint reinforcement shall consist of at least one No. 4
bar spaced not more than 48 inches (1219 mm). Horizontal reinforcement shall be provided
within 16 inches (406 mm) of the top and bottom of these masonry elements.
2. Vertical reinforcement. Vertical reinforcement shall consist of at least one No. 4 bar spaced
not more than 48 inches (1219 mm). Vertical reinforcement shall be within 16 8 inches
(406mm) of the ends of masonry walls.
67
Chapter 18.16
AMENDMENTS TO CHAPTER 8; ROOF -CEILING CONSTRUCTION,
OF THE CALIFORNIA RESIDENTIAL CODE
Sections:
18.16.005 Chapter 8 is Amended
18.16.010 Subsection R803.2.4 is Added
18.16.005 Chapter 8 is Amended.
The following sections of Chapter 8 of the California Residential Code, as adopted by Chapter
18.01 hereof, are added, deleted, or amended as follows:
18.16.010 Subsection R803.2.4 is Added
Subsection R803.2.4 is added to read as follows:
R803.2.4 Openings in horizontal diaphragms. Openings in horizontal diaphragms shall
conform to Section R503.2.4.
68 4
Chapter 18.17
AMENDMENTS TO CHAPTER 10; CHIMNEYS AND FIREPLACES,
OF THE CALIFORNIA RESIDENTIAL CODE
Sections:
18.17.005 Chapter 10 is Amended
18.17.010 Subsection R1001.3.1 is Amended
18.17.005 Chapter 10 is Amended.
The following sections of Chapter 10 of the California Residential Code, as adopted by Chapter
18.01 hereof, are added, deleted, or amended as follows:
18.17.010 Subsection R1001.3.1 is Amended
Subsection R1001.3.1 is amended to read as follows:
R1001.3.1 Vertical reinforcing. For chimneys up to 40 inches (1016 mm) wide, four No. 4
continuous vertical bars adequately anchored into the concrete foundation shall be placed between
wythes of solid masonry or within the cells of hollow unit masonry and grouted in accordance
with Section R609. Grout shall be prevented from bonding with the flue liner so that the flue liner
is free to move with thermal expansion. For chimneys more than 40 inches (1016 mm) wide, two
additional No. 4 vertical bars adequately anchored into the concrete foundation shall be provided
for each additional flue incorporated into the chimney or for each additional 40 inches (10 16 mm)
in width or fraction thereof.
69
Title 19
CITY ELECTRICAL CODE
Chapters:
19.01 Adoption of the City Electrical Code
19.02 Amendments to CEC Chapter 1; General
19.03 Amendments to CEC Chapter 6; Special Equipment
19.04 Amendments to CEC Annex H (Article 80); Administration and Enforcement
Chapter 19.01
ADOPTION OF THE CITY ELECTRICAL CODE
Sections:
19.01.010 Adoption of the City Electrical Code
19.01.010 Adoption of the City Electrical Code
There is adopted by reference that certain code known and designated as the California Code of Regulations,
Title 24, Part 3, further described and referred to as the 2013 California Electrical Code published by the
California Building Standards Commission and based on the National Electric Code®, 2011 Edition, prepared
by the National Fire Protection Association.
Adoption of said code shall include those articles, sections, and annexes requiring enforcement by the local
building department and as further amended by the City of Santa Clarita with provisions intended to address
local climatic, geologic, and/or topographic conditions, as permitted by State law. Adoption of said code shall
include adoption of the following annexes: Annex A, Product Safety Standards, Annex B, Application
Information for Ampacity Calculation, Annex C, Tables, Annex D, Examples, Annex E, Types of
Construction, Annex F, Critical Operations power Systems, and Annex H, Administration.
Such code shall be and become the Santa Clarita Electrical Code, regulating and controlling the design,
construction, installation, quality of materials, location, operation and maintenance of electrical systems,
equipment and appliances. The provisions of said code shall provide for the issuance of permits and collection
of fees thereof, and providing penalties for violation of such Code.
The City Electrical Code shall become effective for new permit applications received by the City on or after
January 1, 2014.
At least one copy of the City Electrical Code has been deposited in the office of the City Clerk and shall be at
all times maintained by the clerk for use and examination by the public.
Chapter 19.02
AMENDMENTS TO CHAPTER 1; GENERAL,
OF THE CALIFORNIA ELECTRICAL CODE
Sections:
19.02.005 Chapter 1; General is Amended
19.02.010 Article 100 is Amended
19.02.005 Chapter 1; General is Amended.
The following sections of Chapter 1 of the California Electrical Code, as adopted by Chapter 19.01 hereof, are
added, deleted, or amended as follows:
19.02.010 Article 100 is Amended.
Article 100 Definitions is amended to add the following definitions and declarations:
• Apartment House. Any building or portion thereof, which is designed, built, rented, leased, let or hired
out to be occupied, or which is occupied as the home or residence of three or more families living
independently of each other and doing their own cooking in said building, and shall include flats and
apartments.
• Approved. Acceptable to the Building Official.
• Building. Any structure built for the support or shelter of persons, animals, chattels, or property of any
kind.
• Dwelling. Any building or any portion thereof which is not an "Apartment House" or a "Hotel" as defined
in this Code, which contains one or more "Apartments" or "Guest Rooms," used, intended or designed to
be built, used, rented, leased, let or hired out to be occupied, or which are occupied for living purposes.
• Dwelling Unit. One or more habitable rooms which are occupied or which are intended or designed to be
occupied by one family with facilities for living, sleeping, cooking and eating.
• Electric or electrical wiring. The installation or the alteration of any material, fixture, device, appliance
or equipment in or on any building, structure or premises, used or designed or intended to be used to
generate, transmit, transform or utilize electric energy.
• Grade (adjacent Ground Elevation). The lowest point of elevation of the finished surface of the ground,
paving or sidewalk within the area between the building and the property line or, when the property line is
more than five feet from the building, between the building and a line five feet from the building.
• Hotel. Any building containing six or more rooms intended or designed to be used, or which are used,
rented or hired out to be occupied, or which are occupied for sleeping purposes by guests.
• Person. An individual human being, a firm, partnership or corporation, his or their heirs, executors,
administrators, assignees, officers or agents; the City of Santa Clarita, and any local agency as defined in
Section 53090 of the Government Code, or officer thereof.
• Service. For purposes of interpreting the National Electrical Code (NEC), each service drop or lateral to a
building shall be considered one service. For purposes of determining the fees to be paid, each service and
piece of service equipment shall be subject to the fees set forth in section 19.04.080.
• Service Equipment. One or more fused switches, enclosed circuit breakers, panelboards, switchboards,
and/or switchgear supplied by one service and intended to constitute the main control and means of cut-off
of the electrical supply. One service may include several pieces of service equipment. Permit fees shall be
paid for each piece of service equipment.
• Special Permission. Written consent of the Building Official.
• Tenant Improvement (Electrical). Electrical work that alters or adds to the wiring system of an existing
tenant space, whether previously occupied or not, in a building that has previously passed final electrical
inspection regardless of whether the building is a fully developed building or only a shell.
I
Chapter 19.03
AMENDMENTS TO CHAPTER 6 OF THE CALIFORNIA ELECTRICAL CODE
Sections:
19.03.005 Chapter 6 is Amended
19.03.010 Section 690.19 is Added
19.03.005 Chapter 6 is Amended.
The following sections of Chapter 6, Special Equipment, of the California Electrical Code, as adopted by
Chapter 19.01 hereof, are added, deleted or amended as follows:
19.03.010 Section 690.19 is Added.
Section 690.19 is added to read as follows:
690.19 Disconnecting Means for Multiple Arrays. Where more than one array is combined to form a
single output rated more than 50 volts and/or 10 amperes, a disconnecting means rated for the output shall be
installed immediately adjacent to the combiner box on the output side.
EXCEPTION No. 1: If the combiner box is located adjacent to the inverter(s), the
disconnecting means as stated above shall not be required.
EXCEPTION No. 2: DC disconnect is not required on the output side of a combiner box for
R-3 and U occupancies accessory to R-3 for rooftop installations.
Chapter 19.04
AMENDMENTS TO ANNEX H (ARTICLE 80)
OF THE CALIFORNIA ELECTRICAL CODE
Sections:
19.04.005
Annex H, Article 80, is Amended
19.04.010
Section 80.7 is Deleted
19.04.020
Section 80.13 is Amended
19.04.030
Subsection 80.13(17) is Added
19.04.040
Section 80.15 is Amended
19.04.050
Subsection 80.19(A)(3) is Added
19.04.060
Subsection 80.19(C) is Amended
19.04.070
Subsection 80.19(D) is Amended
19.04.080
Subsection 80.19(E) is Amended
19.04.090
Section 80.21 is Amended
19.04.100
Subsections 80.21(D), (E), (F), and (G) are Added
19.04.110
Subsection 80.23(B)(3) is Amended
19.04.120
Section 80.25 is Amended
19.04.130
Section 80.27 is Deleted
19.04.140
Section 80.29 is Amended
19.04.150
Section 80.35 is Deleted
19.04.005 Annex H, Article 80, is Amended.
The following sections of Annex H, Article 80, of the California Electrical Code, as adopted by Chapter
19.01 hereof, are added, deleted, or amended as follows:
19.04.010 Section 80.7 is Deleted.
Section 80.7 is deleted in its entirety.
19.04.020 Section 80.13 is Amended.
Section 80.13 is amended to read as follows:
90.13 Authority. There is established within the City of Santa Clarita a division in the Public
Works Department to be known as the Building and Safety Division under the administrative
and operational control of the City Building Official hereinafter referred to as the Building
Official. Where used in this article, the term authority having jurisdiction shall be construed to
mean the City Building Official of the City of Santa Clarita.
This Code shall be administered and enforced by the authority having jurisdiction designated
by the governing body as follows.
(Provisions 1 through 16 under this section remain the same)
19.04.030 Subsection 80.13(17) is Added.
Subsection 80.13(17) is added to read as follows:
(17) A written application shall be submitted for a proposed alternate material, method of
construction or waiver together with a fee established by the City Council. The details of any
action granting an alternate material or method of construction shall be noted in the files of the
Building and Safety Division of the City.
19.04.040 Section 80.15 is Amended.
Section 80.15 is amended in its entirety to read as follows:
80.15 Electrical Board. The electrical board shall be the Appeals Board as established under
the provisions of the Santa Clarita Building Code Section 18.02.200, hereinafter designated as
the Board.
19.04.050 Subsection 80.19(A)(3) is Added.
Subsection 80.19(A)(3) is added to read as follows:
(3) The Building Official may refuse to issue a permit for temporary or permanent service
when there is no apparent legally permitted use for the service. In determining whether a
proposed use is legally permitted, the Building Official may consider not just the provisions of
the Electrical Code but all applicable statutes, ordinances, rules and regulations.
19.04.060 Subsection 80.19(C) is Amended.
Subsection 80.19(C) is amended in its entirety to read as follows:
80.19(C) Issuance of Permits. The Building Official is authorized to issue a permit to the
applicant for the work described in the application and plans filed therewith, when it is
determined that all of the following items comply:
1. The work conforms to the requirements of this code and other pertinent laws and
ordinances.
2. The required clearances from all other agencies have been obtained.
3. The appropriate fees specified by this code have been paid.
When a permit is issued and plans and/or specifications have been required to be provided, the
Building Official shall endorse in writing or stamp upon the pians and/or specifications
"APPROVED." Such approved plans and specifications shall not be changed, modified or
altered without authorizations from the Building Official, and design professional of record
when applicable, and all work regulated by this code shall be done in accordance with the
approved plans, however the approval of the plans shall not be construed as a waiver of any
requirement of this code, or any other law or ordinance, unless specific documentation such as
that required by Subsections 80.13 (15) and (16) is provided. The issuance of a permit shall not
be deemed to certify that the site of the described work is safe.
No permit shall be required for the following electrical work:
1. Minor repair work such as the replacement of lamps, switches, receptacle devices, sockets,
taping bare joints and the like, or the connection of portable motor and appliances to suitable
receptacles which have been permanently installed.
2. The temporary wiring for temporary theater, motion picture or television stage sets.
3. The repair of fixed motors, transformers, apparatus, or appliances.
4. Temporary holiday decorative lighting provided no such lighting is `hard wired' directly
into an electric panel or sub -panel.
5. The installation of temporary wiring for testing or experimental purposes within suitable
facilities.
6. Repair or replacement of overcurrent devices.
7. Portable generators, motors, appliances, tools, power outlets, and other portable equipment
connected by means of a cord or cable having an attachment plug.
8. The installation by Southern California Edison Company of radio -controlled relays on
privately owned air conditioning and agricultural irrigation pumping equipment in the
company's pilot program of energy conservation through electrical load management, entitled
"Air Conditioner Cycling and Agricultural and Pumping Interruptible Programs" provided that
a. The relays shall be tested and labeled by Underwriters' Laboratories, Inc.
b. The Building Official shall approve of specifications for the installation of the relays.
c. The relays shall be installed and maintained by Southern California Edison Company or
its contractors.
d. The Southern California Edison Company shall make available for random inspection,
upon request of and by the City, designated relay installations to ensure code compliance.
9. Private telephone, intercom, sound and communication systems, data, security alarm, and
television cable in single family dwellings; provided, however, that a permit shall be obtained
for any added circuits supplying the power supplies required by the above systems.
10. Nonresidential communication, telephone, and data cabling systems. Nonresidential
security systems may be exempted when such system is independent of the fire
protection/alarm system.
11. Exemption for Utilities. The provisions of this code shall not apply to any electrical work
performed by or for any electrical corporation, telephone corporation, telegraph corporation,
railroad corporation or street railroad corporation on or with any electrical equipment owned or
controlled and operated or used by, and for the exclusive benefit of, such corporation in the
conduct of its business as a public utility, or to any other work which any such corporation shall
be entitled by law to perform without payment of any local tax; but all provisions of this code
shall apply insofar as they may consistently with the above be applicable to all other electrical
work performed by or for any such corporation.
The terms "electrical corporation," "telephone corporation," "telegraph corporation," 'railroad
corporation," and "street railroad corporation," are herein used as said terms are respectively
defined in the Public Utility Code of the State of California; and such terms shall also be
deemed to include similar utilities which are municipally or governmentally owned and
operated.
Notwithstanding the foregoing, all electrical wiring and equipment installed, altered, repaired,
or replaced shall comply with the provisions of this code.
19.04.070 Subsection 90.19(D) is Amended.
Subsection 80.19(D) is amended in its entirety to read as follows:
(D) Owner -Builder permits. Where a permit is issued as an 'Owner -Builder' for an electrical
installation and such installation is of a more complex nature including but not limited to any of the
following:
F1,1A
1. Installation or modification of distribution equipment, including main service and subpanels,
2. Installation of any interconnected power production systems,
3. Installation of any circuit greater than 20amps,
the permittee must provide documentation at the time of permit issuance that the work will be
performed by a 'qualified person' as defined in Article 100 herein. Such documentation shall
include one of the following:
1. Documentation acceptable to the Building Official of training demonstrating the permittee or
his employee possesses the skills and knowledge related to the construction and operation of
the electrical equipment and/or installation as described in the permit including documentation
of safety training to recognize and avoid the hazards involved. Any of the following would be
considered acceptable documentation:
a. A journeyman electrician certificate
b. A C-10 electrical contractor's license
c. A certificate or other documentation showing satisfactory completion of a course in
electrical installation and safety training from an accredited trade school
d. A degree in electrical engineering from an accredited college or university
e. Completion of electrical safety training complying with NFPA 7013-2009
f. Other documentation acceptable to the Building Official
2. Where the permittee chooses to have the work done by a licensed electrical contractor, the
name and license information of the contractor shall be provided.
19.04.050 Subsection 50.19(E) is Amended.
Subsection 80.19(E) is amended in its entirety to read as follows:
(E) Fees.
1. General. The City shall collect such fees as are required by this code as established by the
City Council and issue receipts therefor, copies of which shall be maintained as record in the
office of Building and Safety.
2. Cost of Permit. The cost of electrical permits shall be as established by the City Council.
3. Refund. In the event that any person shall have obtained an electrical permit and no portion
of the work covered by such permit has been commenced and such permit shall have been
canceled and a written request for cancellation, having been approved by the Building Official,
the applicant/permittee may request a refund from the City for a maximum of eighty (80)
percent of the permit fees paid excluding issuance fees or plan review fees.
4, The applicant shall present all necessary documentation including the original signed
permit and inspection record card to the Building Official showing they are entitled to receive
such refund of the permit fee as described above. No refunds shall be granted after 90 days
from the expiration of the permit. No refund shall be made for a permit which was obtained by
falsification or misrepresentation and which was subsequently revoked for such cause.
5. Work Without a Permit. Whenever any work for which a permit is required by this code
has been commenced without first obtaining said permit, a special investigation shall be made
before a permit may be issued for such work.
6. Investigation Fee. An investigation fee shall be collected whether or not a permit is then or
subsequently issued. The investigation fee shall be twice the amount of the permit fee required
by this code and shall be in addition to any fees for permits issued in connection with the work
investigated. The payment of such investigation fee shall not exempt any person from
compliance with all other provisions of this code nor from any penalty prescribed by law.
19.04.090 Section 80.21 is Amended.
Section 80.21 is amended to read as follows:
80.21 Plans Review. Review of plans and specifications, submittal document requirements,
plan review fees, and expiration of plan review shall conform to (A) through (G).
19.04.100 Subsections 80.21(D), (E), (F), and (G) are Added.
Subsections 80.21(D), (E), (F), and (G) are added to read as follows:
(D) Submittal Documents. The Building Official shall require the submission of plans,
specifications, drawings, descriptions and diagrams as appropriate to clearly show the
character, kind, and extent of electrical work covered by an application for a permit. Such
documents may be submitted in electronic format upon approval of the Building Official.
Exception: If in the opinion of the building official the scope of work is determined to be of a
minor nature, the submittal of such documents may be waived by the Building Official.
(E) Information Required on Plans.
1. Every plan required by subsection (D) of this section shall be a print or other type approved
by the Building and Safety Division. Electronic media documents may be submitted as
determined by the Building Official. The information contained on the plans shall be drawn in
a professional manner, be clearly legible and contain the information required in subsection
(E)(2) of this section. labeling, lettering, dimensioning, and numbering shall be of a size and
style to be easily read and shall be in conformance with accepted professional practices and
standards for architectural and engineering documents. Reasonable symbols satisfactory to the
Division shall be used in all plans. Submitted plans and specifications, which are deemed
incomplete or incorrect, shall be returned to the architect or registered engineer or other
individual in general responsible charge with a request for compliance with these regulations
before checking is begun or resumed by Building & Safety Division staff.
2. The following is required to be shown on the plans for all electrical installations requiring a
permit:
a. A complete single line diagram;
b. The type, location, and capacity of all service equipment;
c. The size and length of all feeder raceways;
d. The dimensions of all pull or junction boxes larger than four (4) inches trade size;
e. The number, size, and type of all conductors to be installed in each feeder circuit;
I. The location of every proposed outlet and switch in all parts of the building or
structure, including all fixed showcases, wall -cases, office furnishings, and similar wiring
and the location of all existing circuits and outlets within or related to the areas of new or
modified electrical installations;
g. The location, voltage and HP rating of every motor that is not a component of a listed
appliance and the KW rating of every generator;
h. The location and KVA or equivalent rating of each transformer and similar equipment;
and the location and ampere or wattage rating of other appliances of the noninductive type;
L Details of panelboard, switchboard and motor control center schedules, showing wattage
and amperage, of active branch circuits to be installed or modified, and the number of spare
branch circuits for future use. This shall include identifying the circuits to which the outlets
are connected and listing the number and type of outlets;
j. A lighting fixture schedule;
k. The existing load, as calculated in accordance with Articles 210 and 220 of the NEC or
by other methods satisfactory to the Building Official shall be indicated for existing
installations, alterations, or additions made thereto;
1. Other additional information as the Building Official may consider necessary for proper
enforcement of this code.
Exception (1): R-3 and U occupancies that are accessory to R-3. Information required is
limited to the location of all electrical outlets, including, but not limited to receptacles,
switches, lighting, power for appliances, disconnecting means for appliances, and the location
and size of the electrical service and any sub-pane](s). Alternative power source systems and
specialized electrical installations may require more information on the plans.
Exception (2): Some or all plan requirements may be waived at the discretion of the Building
Official for work considered to be of a minor nature.
(F) Plan Review Fees. Plan review fees shall be paid when the plans are submitted for review.
The cost of the electrical plan review shall be as established by the City Council.
(G) Expiration of Plan Review. Applications for which no electrical permit has been issued
within one hundred eighty (180) days following the date of application, shall expire by
limitation, and plans and other data submitted for review may thereafter be returned to the
applicant or destroyed by the Building Official. The Building Official may extend the time for
action by the applicant for a period not exceeding one hundred eighty (180) days on request by
the applicant showing that circumstances beyond the control of the applicant have prevented
action from being taken. The Building Official may collect a fee for any application for
extension of plan review in accordance with the City's fee schedule. No application shall be
extended more than twice. In order to renew action on an application after expiration, the
applicant shall resubmit plans and pay a new plan review fee.
19.04.110 Subsection 80.23(B)(3) is Amended.
Subsection 80.23(B)(3) is amended to read as follows:
(B) Penalties.
(3) Any person, firm, or corporation who violates any of the provisions of this code is guilty of
a misdemeanor punishable by a fine not exceeding one thousand dollars ($1,000.00) or by
imprisonment not exceeding six (6) months, or by both such fine and imprisonment, (see
Section 17995 of the State Health and Safety Code), unless such violation is otherwise declared
to be an infraction by the City Council. Such person shall be guilty of a separate offense for
each and every day or portion thereof during which any violation of any of the provisions of
this code is committed, continued, or permitted to remain.
10 ��
19.04.120 Section 80.25 is Amended.
Section 80.25 is amended to read as follows:
80.25 Connection to Electricity Supply. Connection to the electric supply shall conform to
(A) through (D).
(A) Authorization. Except as provided in 80.25, it shall be unlawful for any person, firm, or
corporation to make connection to a supply of electricity or to supply electricity to any electric
equipment installation for which a permit is required or that has been disconnected or ordered
to be disconnected.
(B) Special Consideration. By special permission of the Building Official, temporary power
shall be permitted to be supplied to the premises for specific needs of the construction project.
(C) Disconnection. The Building Official is empowered to disconnect or to order in writing the
discontinuance of electrical service to wiring, devices or materials found to be dangerous and a
hazard to life, health and property until the installation of such wiring, device or material has
been made safe as directed by the Building Official.
Any person, firm, corporation, public utility, political subdivision or governmental agency
ordered to discontinue such electrical service shall do so within twenty-four (24) hours after the
receipt of such written notice and shall not reconnect such service or allow or cause the same to
be reconnected until notified to do so by the Building Official.
(D) Service upgrades. Prior to the replacement of any electrical service, the licensed electrical
contractor shall contact the local Utility Planning Department for guidance and shall proceed as
directed by the Utility. Electrical supply lines shall not be reconnected to the service equipment
until the installation has been inspected by the Building Official or an authorized representative of
the Building Official. Under no circumstances shall a representative of the City of Santa Clarita
inspect a service with exposed, energized components.
19.04.130 Section 80.27 is Deleted.
Section 80.27 is deleted in its entirety.
19.04.140 Section 80.29 is Amended.
Section 80.29 is amended to read as follows:
80.29 Liability for Damages. Article 80 shall not be construed to affect the responsibility of
liability of any party owning, designing, operating, controlling, or installing any electric
equipment for damages to persons or property caused by a defect therein, nor shall the City of
Santa Clarita or any of its employees by held as assuming any such liability by reason of the
inspection, re -inspection, or other examination authorized.
19.04.150 Section 80.35 is Deleted.
Section 80.35 is deleted in its entirety.
Title 20
CITY PLUMBING CODE
Chapters;
20.01
Adoption of the City Plumbing Code
20.02
Amendments to CPC Chapter 1 Division II; Administration
20.03
Amendments to CPC Chapter 3; General Regulations
20.04
Amendments to CPC Chapter 4; Plumbing Fixtures and Fixture Fittings
20.05
Amendments to CPC Chapter 7; Sanitary Drainage
Chapter 20.01
ADOPTION OF THE CITY PLUMBING CODE
Sections:
20.01.010 Adoption of the City Plumbing Code
20.01.010 Adoption of the City Plumbing Code.
There is hereby adopted by reference that certain code known and designated as the California Code
of Regulations, Title 24, Part 5, further described and referred to as the 2013 California Plumbing
Code published by the California Building Standards Commission and based on the Uniform
Plumbing Code®, 2012 Edition, prepared by the International Association of Plumbing and
Mechanical Officials.
The adoption of said code shall include those sections requiring enforcement by the local building
department as mandated by the State and as further amended by the City of Santa Clarita with
provisions intended to address local climatic, geologic, and topographic conditions, as permitted by
State law. Adoption of said code shall include the adoption of the following appendices: Appendix A,
Appendix B, Appendix D, Appendix G, and Appendix I.
Such code shall be and become the Santa Clarita Plumbing Code, regulating plumbing and drainage
systems, house sewers, private sewage disposal, drainage systems, and prescribing conditions under
which such work may be carried on within the City and providing for the issuance of permits and the
collection of fees therefore.
The City Plumbing Code shall become effective for new permit applications received by the City on
or after January 1, 2014.
At least one copy of the City Plumbing Code has been deposited in the office of the City Clerk and
shall be at all times maintained by the Clerk for use and examination by the public.
9
Chapter 20.02
AMENDMENTS TO CHAPTER 1, DIVISION II OF THE
Sections:
20.02.005
20.02.010
20.02.020
20.02.030
20.02.040
20.02.050
20.02.060
20.02.070
20.02.080
CALIFORNIA PLUMBING CODE
Chapter 1 Division II is Amended
Subsection 101.1 is Amended
Subsection 101.4.4 is Amended
Subsection 102.1 is Amended
Subsection 102.4 is Amended
Subsection 103.4.1 is Amended
Subsection 103.4.2 is Amended
Subsection 103.4.4.2 is Amended
Subsection 103.4.5.2 is Amended
20.02.005 Chapter 1 Division H is amended.
The following sections of Chapter 1, Division 11 of the California Plumbing Code, as adopted by
Section 20.01 hereof, are added, deleted, or amended as follows:
20.02.010 Subsection 101.1 is Amended
Subsection 101.1 is amended to read as follows:
101.1 Title These regulations shall be known as the Santa Clarita Plumbing Code and shall be
used in conjunction with the provisions of Title 24, California Code of Regulations, mandated by
the State of California to be enforced by the local building department, all of which may be cited
herein as "this code."
20.02.020 Subsection 101.4.4 is Added
Subsection 10 1.4.4 is added to read as follows:
101.4.4 Work in Public Right -of -Way. No person shall install, remove, alter or repair any sewer
or part thereof which is located in any public way in the City of Santa Clarita without having fust
obtained a permit from the City Engineer or the State Department of Transportation,
(CALTRANS), whichever agency may have jurisdiction over the particular thoroughfare affected.
20.02.030 Subsection 102.1 is Amended
Section 102.1 is amended to read as follows:
102.1 Authority Having Jurisdiction.
There is established within the City of Santa Clarita, a division in the Public Works Department
known as the Building & Safety Division under the administrative and operational control of the
City Building Official. The City Building Official is designated as the Authority Having
Jurisdiction duly appointed to enforce this code.
Whenever the term "Authority Having Jurisdiction" or 'Building Official" is used in any section
of this code such term shall be construed to mean the City Building Official of the City of Santa
Clarita.
20.02.040 Subsection 102.4 is Added
Subsection 102.6 is added to read as follows:
102.4 Appeals.
Appeals of determination made by the Building Official for this code shall be made in accordance
with Chapter 18.02 Subsection 18.02.210 of Title 18—City Building Code.
20.02.050 Subsection 103.4.1 is Amended
Subsection 103.4.1 is amended to read as follows:
103.4.1 Permit Fees. The fee for each permit shall be as set forth and adopted by the City
Council.
20.02.060 Subsection 103.4.2 is Amended
Subsection 103.4.2 is amended to read as follows
103.4.2 Plan Review Fees. When plans or other data are required to be submitted by Section
103.2.2, a plan review fee shall be paid at the time of submitting plans and specifications for
review.
The plan review fees for plumbing work shall be as set forth and adopted by the City Council.
The plan review fees specified in this subsection are separate fees from the permit fees specified
in this section and are in addition to the permit fees.
When plans are incomplete or changed so as to require additional review, an additional plan
review fee shall be charged at the rate adopted by the City Council.
20.02.070 Subsection 103.4.4.2 is Amended
Subsection 103.4.4.2 is amended to read as follows:
103.4.4.2 An investigation fee, in addition to the permit fee, shall be collected whether or not a
permit is then or subsequently issued. The investigation fee shall be equal to twice the amount of
the permit fee that would be required by this code if a permit were to be issued and shall be in
addition to any fees for permits issued in connection with the work investigated. The minimum
investigation fee shall be as established by the City Council. The payment of such investigation
fee shall not exempt any person from compliance with all other provisions of this code, nor from
any penalty prescribed by law.
20.02.080 Subsection 103.4.5.2 is Amended
Subsection 103.4.5.2 is amended to read as follows:
103.4.5.2 The Building Official may authorize the refunding of not more than 80 percent of any
fee paid hereunder, excluding issuance fees or plan review fees, when no work has been done
under a permit issued in accordance with this code. No refund shall be authorized except on
written application filed by the original applicant or pemtittee not later than 90 days after the date
the permit has expired or been cancelled.
4 (��
Chapter 20.03
AMENDMENTS TO CHAPTER 3 OF THE CALIFORNIA PLUMBING CODE
Sections:
20.03.005 Chapter 3 is Amended
20.03.010 Subsection 301.1.5 is Added
20.03.005 Chapter 3 is Amended.
The following sections of Chapter 3 of the California Plumbing Code, as adopted by Section 20.01
hereof, are added, deleted, or amended as follows:
20.03.010 Subsection 301.1.5 is Added
Subsection 301.1.5 is added to read as follows:
301.15 Used Materials. Previously used industrial apparatus and processing equipment
may be reinstalled provided it complies with all applicable provisions of this code.
91m
Chapter 20.04
AMENDMENTS TO CHAPTER 4 OF THE CALIFORNIA PLUMBING CODE
Sections:
20.04.005 Chapter 4 is Amended
20.04.010 Subsection 422.2, Exception (3) is Amended
20.04.005 Chapter 4 is Amended.
The following section of Chapter 4 of the California Plumbing Code, as adopted by Section 20.01
hereof, are added, deleted, or amended as follows:
20.04.010 Subsection 422.2, Exception (3) is Amended
Subsection 422.2, Exception (3) is amended to read as follows:
422.2, Exception (3) In business and mercantile occupancies with a total occupant load of
50 or less, including customers and employees based on Table 1004.1.2 of the 2013 California
Building Code, one toilet facility, designed for use by no more than one person at a time, shall
be permitted for use by both sexes. (Amended for clarity only)
Chapter 20.05
AMENDMENTS TO CHAPTER 7 OF THE CALIFORNIA PLUMBING CODE
Sections:
20.05.005 Chapter 7 is Amended
20.05.010 Subsection 714.6 is Added
20.05.020 Subsection 714.7 is Added
20.05.005 Chapter 7 is Amended.
The following sections of Chapter 7 of the California Plumbing Code, as adopted by Section 20.01
hereof, are added, deleted, or amended as follows:
20.05.010 Section 714.6 is Added.
Section 714.6 is added to read as follows:
714.6 Water softener systems using dry wells for the discharge of effluents are prohibited in
the City of Santa Clarks.
Exception: Systems with regeneration cycles discharging quantities of total dissolved solids
that do not exceed those stipulated in the water quality objectives set by the Regional Water
Quality Control Board when approved by the Building Official,
20.05.020 Section 714.7 is Added.
Section 714.7 is added to read as follows:
714.7 Automatic or self -regenerating water softener systems using sodium chloride (salt) or
potassium chloride are prohibited in the City of Santa Clarita.
Exception: Commercially installed water softener systems that utilize portable exchange
tanks maintained by a commercially licensed company where no brine waste is discharged
into the public sewer system.
Title 21
CITY MECHANICAL CODE
Chapters:
21.01 Adoption of City Mechanical Code
21.02 Amendments to Chapter 1 Division II, Administration
Chapter 21.01
ADOPTION OF THE CITY MECHANICAL CODE
Sections:
21.01.010 Adoption of the City Mechanical Code
21.01.010 Adoption of the City Mechanical Code.
There is hereby adopted by reference that certain code known and designated as the California Code
of Regulations, Title 24, Part 4, further described and referred to as the 2013 California Mechanical
Code published by the California Building Standards Commission and based on the Uniform
Mechanical Code®, 2012 Edition, prepared by the International Association of Plumbing and
Mechanical Officials.
The adoption of said code shall include those sections requiring enforcement by the local building
department and as further amended by the City of Santa Clarity with provisions intended to address
local climatic, geologic, and topographic conditions, as permitted by State law. Adoption of said code
shall include the adoption of the following appendices: Appendix D, Appendix F, and Appendix G.
Such code shall be and become the Santa Clarita Mechanical Code, regulating heating, ventilating,
comfort cooling, refrigeration systems and other miscellaneous heating appliances, prescribing
conditions under which such work may be performed within the City and providing for the issuance of
permits and the collection of fees therefore.
The City Mechanical Code shall become effective for new permit applications received by the City on
or after January 1, 2014.
At least one copy of the City Mechanical Code has been deposited in the office of the City Clerk and
shall be at all times maintained by the Clerk for use and examination by the public.
Chapter 21.02
AMENDMENTS TO CHAPTER 1 DIVISION II OF THE
CALIFORNIA MECHANICAL CODE
Sections:
21.02.005
Chapter 1 Division II is Amended
21.02.010
Section 101.0 is Amended
21.02.020
Section 105.0 is Amended
21.02.030
Section 108.1 is Amended
21.02.040
Section 115.2 is Amended
21.02.050
Section 115.3 is Amended
21.02.060
Section 1155.2 is Amended
21.02.070
Section 115.6.1 is Amended
21.02.080
Section 115.6.2 is Amended
21.02.090
Section 115.6.3 is Amended
21.02.005 Chapter 1 Division II is Amended.
The following sections of Chapter 1 Division II of the California Mechanical Code, as adopted by
Chapter 21.01 hereof, are added, deleted, or amended as follows:
21.02.010 Section 101.0 is Amended
Section 101.0 is amended to read as follows:
101.0 Title. These regulations shall be known as the Santa Clarita Mechanical Code and shall be
used in conjunction with the provisions of Title 24, California Code of Regulations, mandated by
the State of California to be enforced by the local building department, all of which may be cited
herein as "this code."
21.02.020 Section 105.0 is Amended
Section 105.0 is amended to read as follows:
105.0 Alternate Materials and Methods of Construction Equivalency. Nothing in this code is
intended to prevent the use of any material, appliance, installation, device, arrangement, or
method of construction not specifically prescribed, provided any such alternate has been approved
by the Building Official.
The Building Official may approve any such alternate, provided, it is determined that the
proposed design is satisfactory and complies with the technical provisions of this code, and that
the material, method or work offered is, for the purpose intended, at least the equivalent of that
prescribed in this code in suitability, strength, effectiveness, fire resistance, durability, and safety.
Such approval shall be based upon submittal of substantiating data and including, but not limited
to, performance characteristics, measurements, calculations, diagrams, equipment and
construction factors, where applicable.
A written application shall be submitted for a proposed alternate material or method of
construction together with a fee established by the City Council. The details of any action
granting an alternate material or method of construction shall be noted in the files of the
Building & Safety Division of the City.
21.02.030 Subsection 108.1 is Amended
Subsection 108.1 is amended to read as follows:
108.1 General. There is established within the City of Santa Clarita, a division in the Public
Works Department known as the Building and Safety Division under the administrative and
operational control of the City Building Official. The City Building Official is designated as the
Authority Having Jurisdiction duly appointed to enforce this code.
Whenever the term "Authority Having Jurisdiction" or 'Building Official' is used in any section
of this code such term shall be construed to mean the City Building Official of the City of Santa
Clarita.
The Building Official is authorized and directed to enforce all of the provisions of this code and to
make inspections pursuant to the provisions of this code. For such purposes the Building Official
shall have the powers of a law enforcement officer.
The Building Official shall have the power to render interpretations of this code and to adopt and
enforce rules and regulations supplemental to this code as may be deemed necessary in order to
clarify the application of the provisions of this code. Such interpretations, rules, and regulations
shall be in conformity with the intent and purpose of this code.
21.02.040 Subsection 115.2 is Amended
Subsection 115.2 is amended as follows:
115.2 Permit Fees. The fee for each permit shall be as set forth and adopted by the City Council.
21.02.050 Subsection 115.3 is Amended
Subsection 115.3 is amended as follows:
115.3 Plan Review Fees. When plans or other data are required to be submitted by Section
113.2, a plan review fee shall be paid at the time of submitting plans and specifications for
review. The plan review fees for mechanical work shall be as set forth and adopted by the City
Council.
The plan review fees specified in this subsection are separate fees from the permit fees specified
in section 115.2 and are in addition to the permit fees.
When plans are incomplete or changed so as to require additional plan review, an additional plan
review fee shall be charged at the rate adopted by the City Council.
21.02.060 Subsection 115.5.2 is Amended
Subsection 115.5.2 is amended to read as follows:
115.5.2 Investigation Fee. An investigation fee, in addition to the permit fee, shall be collected
whether or not a permit is then or subsequently issued. The investigation fee shall be equal to
twice the amount of the permit fee that would be required by this code if a permit were to be
issued and shall be in addition to any fees for permits issued in connection with the work
investigated. The minimum investigation fee shall be as established by the City Council. The
payment of such investigation fee shall not exempt any person from compliance with all other
provisions of this code, nor from any penalty prescribed by law.
4
0
21.02.070 Subsection 115.6.1 is Amended
Subsection 115.6.1 is amended to read as follows:
115.6.1 The Building Official may authorize the refunding of not more than 80 percent of the
permit fee, excluding issuance fees or plan review fees, paid hereunder when no work has been
done under a permit issued in accordance with this code.
21.02.080 Subsection 115.6.2 is Amended
Subsection 115.6.2 is amended to read as follows:
115.6.2 The Building Official may authorize the refunding of not more than 80 percent of the plan
review fee paid hereunder, when an application for a permit for which a plan review fee has been
paid is withdrawn or canceled before any plan review effort has been expended.
21.02.090 Subsection 115.6.3 is Amended
Subsection 115.6.3 is amended to read as follows:
115.6.3 The Building Official shall not authorize refunding of any fee paid except upon written
application filed by the original permittee or applicant not exceeding 90 days from the expiration
or cancellation of the permit or application for a permit.
Title 22
FIRE CODE
Chapters:
22.01 Adoption of the City Fire Code
Chapter 22.01
ADOPTION OF THE CITY FIRE CODE
Sections:
22.01.010 Adoption of the City Fire Code
22.01.010 Adoption of the City Fire Code
There is hereby adopted by reference that certain code known and designated as the California Code
of Regulations, Title 24, Part 9, further described and referred to as the 2013 California Fire Code
published by the California Building Standards Commission and based on the International Fire
Code®, 2012 Edition, prepared by the International Code Council.
Adoption of said code shall include such amendments to the 2013 California Fire Code as duly
adopted by the County of Los Angeles and referred to as Title 32 of the Los Angeles County Code,
also known as the County of Los Angeles Fire Code.
Such code shall be and become the Santa Clarita Fire Code, regulating and governing the safeguarding
of life and property from fire and explosion hazards arising from the storage, handling and use of
hazardous substances, materials and devices, and from conditions hazardous to life or property in the
occupancy of buildings and premises in the City of Santa Clarita.
The Santa Clarita Fire Code shall become effective January 1, 2014.
At least one copy of the Santa Clarita Fire Code has been deposited in the office of the City Clerk, and
shall be at all times maintained by the Clerk for use and examination by the public.
Title 24
CITY ENERGY CONSERVATION CODE
Chapters:
24.01 Adoption of the City Energy Conservation Code
Page 1 of 2
Chapter 24.01
ADOPTION OF THE CITY ENERGY CONSERVATION CODE
Sections:
24.01.010 Adoption of the City Energy Conservation Code
24.01.010 Adoption of the City Energy Conservation Code
There is hereby adopted by reference that certain code known and designated as California Code of Regulations,
Title 24, Part 6, further described and referred to as the 2013 California Energy Code, published by the
California Building Standards Commission.
Such code shall include those sections requiring enforcement by the local building department, and as further
amended by the City of Santa Clarita with provisions intended to address local climatic, geologic and
topographic conditions, as permitted by State law.
Such Code shall be and become the City of Santa Clarita Energy Conservation Code, regulating the design,
construction, alteration, installation, or repair of building envelopes, space -conditioning systems, water -heating
systems, indoor lighting systems of buildings, and outdoor lighting and signage, and certain equipment to
enhance the efficiency and reduce energy use of such buildings as specifically provided for therein.
The City of Santa Clarita Energy Conservation Code shall become effective for new building permit
applications received by the City on or after January 1, 2014.
At least one copy of the City of Santa Clarita Energy Conservation Code shall be maintained and kept
available for reference and examination by the public at the City's Permit Center public counter.
0
IM
Title 25
CITY GREEN BUILDING STANDARDS CODE
Chapters:
25.01 Adoption of the City Green Building Standards Code
Page I of 2
Chapter 25.01
ADOPTION OF THE CITY GREEN BUILDING STANDARDS CODE
Sections:
25.01.010 Adoption of the City Green Building Standards Code
25.01.010 Adoption of the City Green Building Standards Code
There is hereby adopted by reference that certain code known and designated as the California Code of
Regulations, Title 24, Part 11, further described as the 2013 California Green Building Standards Code, also
referred to as the 2013 CalGreen Code, published by the California Building Standards Commission.
Adoption of said code shall include those sections requiring enforcement by the local jurisdiction, and shall
include the adoption of Appendices A4 and A5 contained therein as voluntary provisions only.
Such Code shall be and become the City of Santa Clarita Green Building Standards Code, regulating the
planning, design, operation, construction, use and occupancy of every new building or structure to ensure
buildings have a more positive environmental impact and encourage sustainable construction practices as
specifically provided for therein.
The City of Santa Clarita Green Building Standards Code shall become effective for new building permit
applications received by the City on or after January 1, 2014.
At least one copy of the City of Santa Clarita Green Building Standards Code shall be maintained and kept
available for reference and examination by the public at the City's Permit Center public counter.
(u�
El
CITY OF SANTA CLARITA
NOTICE OF PUBLIC HEARING
NOTICE IS HEREBY GIVEN:
A public hearing will be held before the City Council of the City of Santa Clarita in the
City Hall Council Chambers, 23920 Valencia Boulevard, First Floor, Santa Clarita,
California, on the 26th day of November, 2013, at or after 6:00 p.m. to consider adoption
of the 2013 California Building Standards Code consisting of the Administrative,
Building, Residential, Electrical, Mechanical, Plumbing, Historical Building, Energy,
Existing Building, Fire, Green Building Standards, and Referenced Standards Codes,
including certain appendices and local amendments, and repealing and replacing Titles 18
through 22, and Titles 24 and 25 of the Santa Clarita Municipal Code.
Proponents, opponents, and any interested persons may appear and be heard on this
matter at that time. A copy of the building codes with local amendments is available for
viewing at the City Clerk's office at City Hall, 23920 Valencia Boulevard, Suite 120,
Santa Clarita, California.
If you wish to challenge this action in court, you may be limited to raising only those
issues you or someone else raised at the public hearing described in this notice, or written
correspondence delivered to the City Council at, or prior to, the public hearing.
Further information regarding the building codes may be obtained at the City's Permit
Center located at City Hall, 23920 Valencia Boulevard, Suite 140, or contact Bill Read,
Assistant Building Official, at (661) 284-1403.